Abstract
The incidence of hip “squeak” associated with ceramic-on-ceramic bearings has been variably reported, ranging from 0.7% to 20.9%. We determined the patients’ perception of squeaking in 306 patients (336 hips) in whom ceramic-on-ceramic total hip arthroplasties (THAs) were performed between 1997 and 2005. A questionnaire regarding hip noise was obtained by telephone. With a minimum followup of 2 years (mean, 3.9 years; range, 2–10 years), 290 patients (320 or 95% of the THAs) completed the questionnaire. Patients reported hip noise in 55 of the 320 THAs (17%); noise was perceived as squeak in 32 of the 320 (10%). Most squeaking hips (29 of 32) were pain-free and symptom-free. One patient was unhappy with his squeaking hip without pain. Our data suggest a much higher incidence of squeak as perceived by patients than previously reported.
Level of Evidence: Level II, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
References
Bierbaum BE, Nairus J, Kuesis D, Morrison JC, Ward D. Ceramic-on-ceramic bearings in total hip arthroplasty. Clin Orthop Relat Res. 2002;405:158–163.
Clarke IC, Manley MT. How do alternative bearing surfaces influence wear behavior? Implant Wear Symposium 2007 Engineering Work Group. J Am Acad Orthop Surg. 2008;16(Suppl 1):S86–S93.
Colwell CW Jr, Hozack WJ, Mesko JW, D’Antonio JA, Bierbaum BE, Capello WN, Jaffe WL, Mai KT. Ceramic-on-ceramic total hip arthroplasty early dislocation rate. Clin Orthop Relat Res. 2007;465:155–158.
D’Antonio JA, Capello WN, Manley MT, Naughton M, Sutton K. A titanium-encased alumina ceramic bearing for total hip arthroplasty: 3- to 5-year results. Clin Orthop Relat Res. 2005;441:151–158.
Garino JP. Modern ceramic-on-ceramic total hip systems in the United States: early results. Clin Orthop Relat Res. 2000;379:41–47.
Hamadouche M, Boutin P, Daussange J, Bolander ME, Sedel L. Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study. J Bone Joint Surg Am. 2002;84:69–77.
Hannouche D, Hamadouche M, Nizard R, Bizot P, Meunier A, Sedel L. Ceramics in total hip replacement. Clin Orthop Relat Res. 2005;430:62–71.
Jarrett CA, Ranawat AS, Bruzzone M, Blum YC, Rodriguez JA, Ranawat CS. The squeaking hip: a phenomenon of ceramic-on-ceramic total hip arthroplasty. J Bone Joint Surg Am. 2009;91:1344–1349.
Keurentjes JC, Kuipers RM, Wever DJ, Schreurs BW. High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings. Clin Orthop Relat Res. 2008;466:1438–1443.
Murphy SB, Ecker TM, Tannast M. Two- to 9-year clinical results of alumina ceramic-on-ceramic THA. Clin Orthop Relat Res. 2006;453:97–102.
Restrepo C, Parvizi J, Kurtz SM, Sharkey PF, Hozack WJ, Rothman RH. The noisy ceramic hip: is component malpositioning the cause? J Arthroplasty. 2008;23:643–649.
Rodriguez JA, Gonzalez DelaValle A, McCook N. Squeaking in total hip replacement: a cause for concern. Orthopedics. 2008;31:874, 877–878.
Sedel L. Evolution of alumina-on-alumina implants: a review. Clin Orthop Relat Res. 2000;379:48–54.
Taylor S, Manley MT, Sutton K. The role of stripe wear in causing acoustic emissions from alumina ceramic-on-ceramic bearings. J Arthroplasty. 2007;22(Suppl 3):47–51.
Walter WL, Insley GM, Walter WK, Tuke MA. Edge loading in third generation alumina ceramic-on-ceramic bearings: stripe wear. J Arthroplasty. 2004;19:402–413.
Walter WL, O’Toole GC, Walter WK, Ellis A, Zicat BA. Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation. J Arthroplasty. 2007;22:496–503.
Willmann G. Ceramic femoral head retrieval data. Clin Orthop Relat Res. 2000;379:22–28.
Acknowledgments
We thank Julie C. McCauley, MPHc, for assistance with statistics and Mary E. Hardwick, MSN, RN, for assistance with editing.
Author information
Authors and Affiliations
Corresponding author
Additional information
Each author certifies that he or she has no commercial associations (eg, consultancies, stock ownership, equity interest, patent/licensing arrangements, etc) that might pose a conflict of interest in connection with the submitted article.
Each author certifies that his or her institution has approved the human protocol for this investigation, that all investigations were conducted in conformity with ethical principles of research, and that informed consent for participation in the study was obtained.
This work was performed at Scripps Clinic, Division of Orthopaedic Surgery, La Jolla, CA, USA.
Electronic supplementary material
Below is the link to the electronic supplementary material.
(MPG 5521 kb)
About this article
Cite this article
Mai, K., Verioti, C., Ezzet, K.A. et al. Incidence of ‘Squeaking’ After Ceramic-on-Ceramic Total Hip Arthroplasty. Clin Orthop Relat Res 468, 413–417 (2010). https://doi.org/10.1007/s11999-009-1083-4
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11999-009-1083-4