High Incidence of Squeaking in THAs with Alumina Ceramic-on-ceramic Bearings

  • Original Article
  • Hip
  • Published:
Clinical Orthopaedics and Related Research

Abstract

Ceramic-on-ceramic bearings in THA are a popular alternative to overcome wear concerns in traditional metal-polyethylene bearings. However, squeaking is a potentially worrisome phenomenon in ceramic-on-ceramic THAs which we observed in some of our patients. We reviewed all 42 patients who underwent 43 ceramic-on-ceramic noncemented THAs during the time of the study. Squeaking, defined as a reproducible sound of squeaking, clicking, or grating, occurred in nine of 43 implants (20.9%). Standard radiographs were normal. We used CT imaging to determine cup anteversion and inclination angles, comparing the squeaking hips with those of a randomly selected control group, but found no differences. We then hypothesized specific design features (stem size, cup size, head size, and neck length of the head) would be risk factors for squeaking. We found a difference in neck length between squeaking and nonsqueaking implants. A neck length of −4 mm or shorter resulted in a relative risk of 5.56 (95% confidence interval, 1.14–27.01) for squeaking. We found a high incidence of squeaking in our population, and we believe this phenomenon is an underreported side effect of these types of bearings. A short neck length of the femoral implant was a risk factor for squeaking in ceramic-on-ceramic THA.

Level of Evidence: Level III, therapeutic study.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Bal BS, Rahaman MN, Aleto T, Miller FS, Traina F, Toni A. The significance of metal staining on alumina femoral heads in total hip arthroplasty. J Arthroplasty. 2007;22:14–19.

    Article  PubMed  Google Scholar 

  2. Barrack RL, Burak C, Skinner HB. Concerns about ceramics in THA. Clin Orthop Relat Res. 2004;429:73–79.

    Article  PubMed  Google Scholar 

  3. Burroughs BR, Hallstrom B, Golladay GJ, Hoeffel D, Harris WH. Range of motion and stability in total hip arthroplasty with 28-, 32-, 38-, and 44-mm femoral head sizes. J Arthroplasty. 2005;20:11–19.

    Article  PubMed  Google Scholar 

  4. D’Antonio J, Capello W, Manley M, Naughton M, Sutton K. Alumina ceramic bearings for total hip arthroplasty: five-year results of a prospective randomized study. Clin Orthop Relat Res. 2005;436:164–171.

    Article  PubMed  Google Scholar 

  5. D’Lima DD, Urquhart AG, Buehler KO, Walker RH, Colwell CW Jr. The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios. J Bone Joint Surg Am. 2000;82:315–321.

    PubMed  CAS  Google Scholar 

  6. Eickmann T, Manaka M, Clarke I, Gustafson A. Squeaking and neck-socket impingement in a ceramic total hip arthroplasty. Bioceramics 15. 2003;240–2:849–852.

    Google Scholar 

  7. Hannouche D, Hamadouche M, Nizard R, Bizot P, Meunier A, Sedel L. Ceramics in total hip replacement. Clin Orthop Relat Res. 2005;430:62–71.

    Article  PubMed  Google Scholar 

  8. Huo MH, Parvizi J, Gilbert NF. What’s new in hip arthroplasty. J Bone Joint Surg Am. 2006;88:2100–2113.

    Article  PubMed  Google Scholar 

  9. Kalteis T, Handel M, Herold T, Perlick L, Paetzel C, Grifka J. Position of the acetabular cup: accuracy of radiographic calculation compared to CT-based measurement. Eur J Radiol. 2006;58:294–300.

    Article  PubMed  Google Scholar 

  10. Kobayashi A, Freeman MA, Bonfield W, Kadoya Y, Yamac T, Al-Saffar N, Scott G, Revell PA. Number of polyethylene particles and osteolysis in total joint replacements: a quantitative study using a tissue-digestion method. J Bone Joint Surg Br. 1997;79:844–848.

    Article  PubMed  CAS  Google Scholar 

  11. Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60:217–220.

    PubMed  CAS  Google Scholar 

  12. Lombardi AV Jr, Mallory TH, Dennis DA, Komistek RD, Fada RA, Northcut EJ. An in vivo determination of total hip arthroplasty pistoning during activity. J Arthroplasty. 2000;15:702–709.

    Article  PubMed  Google Scholar 

  13. Matsuno H, Yudoh K, Kimura T. Failure of the locking mechanisms in cementless acetabular components: a report of 3 cases. SICOT Online Reports. January 2002. Available at: http://www.sicot.org/resources/File/IO_reports/01-2002/1-01-2002.php.

  14. Morlock M, Nassutt R, Janssen R, Willmann G, Honl M. Mismatched wear couple zirconium oxide and aluminum oxide in total hip arthroplasty. J Arthroplasty. 2001;16:1071–1074.

    Article  PubMed  CAS  Google Scholar 

  15. Nevelos J, Ingham E, Doyle C, Streicher R, Nevelos A, Walter W, Fisher J. Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns. J Arthroplasty. 2000;15:793–795.

    Article  PubMed  CAS  Google Scholar 

  16. Nevelos JE, Prudhommeaux F, Hamadouche M, Doyle C, Ingham E, Meunier A, Nevelos AB, Sedel L, Fisher J. Comparative analysis of two different types of alumina-alumina hip prosthesis retrieved for aseptic loosening. J Bone Joint Surg Br. 2001;83:598–603.

    PubMed  CAS  Google Scholar 

  17. Patek SN. Squeaking with a sliding joint: mechanics and motor control of sound production in palinurid lobsters. J Exp Biol. 2002;205:2375–2385.

    PubMed  Google Scholar 

  18. Schuh A, Holzwarth U, Kachler W, Goske J, Zeiler G. [Titanium deposits on the ceramic heads of dislocated total hip replacements] [in German]. Orthopade. 2004;33:1194–1200.

    Article  PubMed  CAS  Google Scholar 

  19. Stewart T, Tipper J, Streicher R, Ingham E, Fisher J. Long-term wear of HIPed alumina on alumina bearings for THR under microseparation conditions. J Mater Sci Mater Med. 2001;12:1053–1056.

    Article  PubMed  CAS  Google Scholar 

  20. Stewart TD, Tipper JL, Insley G, Streicher RM, Ingham E, Fisher J. Long-term wear of ceramic matrix composite materials for hip prostheses under severe swing phase microseparation. J Biomed Mater Res B Appl Biomater. 2003;66:567–573.

    Article  PubMed  Google Scholar 

  21. Stewart TD, Tipper JL, Insley G, Streicher RM, Ingham E, Fisher J. Severe wear and fracture of zirconia heads against alumina inserts in hip simulator studies with microseparation. J Arthroplasty. 2003;18:726–734.

    Article  PubMed  Google Scholar 

  22. Suzuki K, Matsubara M, Morita S, Muneta T, Shinomiya K. Fracture of a ceramic acetabular insert after ceramic-on-ceramic THA: a case report. Acta Orthop Scand. 2003;74:101–103.

    Article  PubMed  Google Scholar 

  23. Taylor S, Manley MT, Sutton K. The role of stripe wear in causing acoustic emissions from alumina ceramic-on-ceramic bearings. J Arthroplasty. 2007;22:47–51.

    Article  PubMed  Google Scholar 

  24. Walter WL, O’Toole GC, Walter WK, Ellis A, Zicat BA. Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation. J Arthroplasty. 2007;22:496–503.

    Article  PubMed  Google Scholar 

  25. White SP, Blom AW, Lee M, Smith EJ. The crescent sign: dissociation of the polyethylene liner from a modular acetabular component in total hip arthroplasty. Skeletal Radiol. 2005;34:620–624.

    Article  PubMed  CAS  Google Scholar 

  26. Yamamoto T, Saito M, Ueno M, Hananouchi T, Tokugawa Y, Yonenobu K. Wear analysis of retrieved ceramic-on-ceramic articulations in total hip arthroplasty: femoral head makes contact with the rim of the socket outside of the bearing surface. J Biomed Mater Res B Appl Biomater. 2005;73:301–307.

    PubMed  Google Scholar 

  27. Yoshimine F, Ginbayashi K. A mathematical formula to calculate the theoretical range of motion for total hip replacement. J Biomech. 2002;35:989–993.

    Article  PubMed  Google Scholar 

Download references

Acknowledgments

We thank Jan Hendriks, medical statistician, for advice and Han Bakens, orthopaedic surgeon, for performing some of the THAs.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to J. C. Keurentjes MD.

Additional information

Each author certifies that he or she has no commercial associations (eg, consultancies, stock ownership, equity interest, patent/licensing arrangements, etc) that might pose a conflict of interest in connection with the submitted article.

Each author certifies that his or her institution has approved or waived approval for the human protocol for this investigation and that all investigations were conducted in conformity with ethical principles of research.

About this article

Cite this article

Keurentjes, J.C., Kuipers, R.M., Wever, D.J. et al. High Incidence of Squeaking in THAs with Alumina Ceramic-on-ceramic Bearings. Clin Orthop Relat Res 466, 1438–1443 (2008). https://doi.org/10.1007/s11999-008-0177-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11999-008-0177-8

Keywords

Navigation