Abstract
The possibility of using neutron activation analysis to link up a secondary to a primary mono-elemental solution was investigated. A procedure was developed for the determination of the ratio between the mass fractions of two solutions. The use of a monitor element was essential to limit the effect of the non-uniformity of the neutron flux during irradiation. The proposed procedure was tested in the case of two molybdenum solutions having the same mass fraction. Although the experiment did not reach the goal, possible ways are suggested to reach the target expanded uncertainty of 0.1 %.
Similar content being viewed by others
References
D’Agostino G, Bergamaschi L, Giordani L, Oddone M, Kipphardt H, Richter S (2014) Use of instrumental neutron activation analysis to investigate the distribution of trace elements among subsamples of solid materials. Metrologia 51:48–53
Kaltenbach A, Noordmann J, Görlitz V, Pape C, Richter S, Kipphardt H, Kopp G, Jährling R, Rienitz O, Güttler B (2015) Gravimetric preparation and characterization of primary reference solutions of molybdenum and rhodium. Anal Bioanal Chem 407:3093–3102
Rienitz O, Schiel D, Görlitz V, Jährling R, Vogl J, Lara-Manzano JV, Zoń A, Fung WH, Buzoianu M, Caciano de Sena R, Augusto dos Reis L, Valiente L, Yim YH, Hill S, Champion R, Fisicaro P, Bing W, Turk GC, Winchester MR, Saxby D, Merrick J, Hioki A, Miura T, Suzuki T, Linsky M, Barzev A, Máriássy M, Cankur O, Ari B, Tunç M, Konopelko LA, Kustikov YA, Bezruchko M (2012) Final report on CCQM-K87: mono-elemental calibration solutions. Metrologia. doi:10.1088/0026-1394/49/1A/08010
Høgdahl OT (1965) Proceedings of the Symposium on Radiochemical Methods of Analysis 1:23-40
De Corte F (1987) The k0-standardisation method. A move to the optimization of Neutron Activation Analysis. Ed. Ryksuniversiteit Gent Faculteit Van de Wettenschappen
GammaVision (2006) Version 6.08; Advanced measurement technology, Inc., Berwyn
Browne E, Tuli JK (2011) Nucl Data Sheets 112:275–446
Browne E, Tuli JK (2013) Nucl Data Sheets 114:1849–2022
Gilmore G, Hemingway JD (1995) Practical gamma-ray spectrometry. Wiley, New York
Kolotov VP, De Corte F (2004) Compilation of k 0 and related data for NAA in the form of electronic database (IUPAC Technical Report). Pure Appl Chem 76:1921–1925
Jovanovic S, Vukotic P, Smodis B, Jacimovic R, Mihaljevic N, Stegnar P (1989) Epithermal neutron flux characterization of the TRIGA Mark II reactor, Ljubljana, Yugoslavia, for use in NAA. J Radioanal Nucl Chem 129:343–349
JGCM 100:2008 (2008) Evaluation of measurement data—guide to the expression of uncertainty in measurement
Blachot J (2002) Nucl Data Sheets 95:679–836
Online available at http://www.ptb.de/emrp/sib09.html
Acknowledgments
Financial support by the European Metrology Research Programme (EMRP) is gratefully acknowledged (EMRP-SIB09 “Purity standards for challenging elements”) [14]. The EMRP is jointly funded by the EMRP participating countries within the European Association of National Metrology Institutes (EURAMET). The authors are grateful to the referee for providing constructive comments and help in improving the contents of this paper.
Author information
Authors and Affiliations
Corresponding author
Additional information
An erratum to this article is available at http://dx.doi.org/10.1007/s10967-017-5307-x.
Electronic supplementary material
Below is the link to the electronic supplementary material.
Rights and permissions
About this article
Cite this article
D’Agostino, G., Bergamaschi, L., Di Luzio, M. et al. The linkup of mono-elemental solutions to the SI using INAA: a measurement procedure and the achievable uncertainty. J Radioanal Nucl Chem 309, 777–786 (2016). https://doi.org/10.1007/s10967-015-4676-2
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10967-015-4676-2