Poly-2-methoxyethylacrylate-coated cardiopulmonary bypass circuit can reduce transfusion of platelet products compared to heparin-coated circuit during aortic arch surgery

  • Original Article
  • Cardiopulmonary Bypass
  • Published:
Journal of Artificial Organs Aims and scope Submit manuscript

Abstract

Several coating techniques for extracorporeal circulation have been developed to reduce the systemic inflammatory response during cardiopulmonary bypass (CPB). We compared the clinical effectiveness and biocompatibility of poly-2-methoxyethylacrylate (PMEA)- and heparin-coated CPB circuits in total aortic arch replacement (TAR) with the prolonged use of the bypass technique. Twenty patients who underwent elective TAR were divided randomly into two equal groups: group P (n = 10) to use PMEA-coated circuits and group H (n = 10) to use heparin-coated circuits. Clinical outcomes, hematological variables, and acute phase inflammatory response were analyzed perioperatively. Demographic, CPB, and clinical outcome data were similar for both groups. Hemoglobin and platelet count showed similar time-course curves. However, the amount of platelet products transfused intraoperatively was significantly larger in group H (group P 26.0 ± 7.0 units; group H 33.0 ± 6.7 units, p = 0.04). Total protein, and albumin levels were significantly higher in group P during and after the operation (total protein, p = 0.04; albumin, p = 0.02). The use of PMEA-coated circuit is associated with retainment of perioperative plasma proteins levels and may help to reduce transfusion of platelet products in TAR in comparison with the heparin-coated circuit.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Butler J, Rocker GM, Westaby S. Inflammatory response to cardiopulmonary bypass. Ann Thorac Surg. 1993;55:552–9.

    Article  CAS  PubMed  Google Scholar 

  2. Ito H, Hamano K, Gohra H, Katoh T, Fujimura Y, Tsuboi H, Esato K. Relationship between respiratory distress and cytokine response after cardiopulmonary bypass. Surg Today. 1997;27:220–5.

    Article  CAS  PubMed  Google Scholar 

  3. Videm V, Svennevig JL, Fosse E, Semb G, Osterud A, Mollnes TE. Reduced complement activation with heparin- coated oxygenator and tubings in coronary bypass operations. J Thorac Cardiovasc Surg. 1992;103:806–13.

    CAS  PubMed  Google Scholar 

  4. Gu YJ, van Oeveren W, Akkerman C, Boonstra PW, Huyzen RJ, Wildevuur CR. Heparin-coated circuits reduce the inflammatory response to cardiopulmonary bypass. Ann Thorac Surg. 1993;55:917–22.

    Article  CAS  PubMed  Google Scholar 

  5. Lazar HL, Zhang X, Hamasaki T, Memmelo CA, Treanor P, Rivers S, Aldea GS, Bernard SA, Shemin RJ. Heparin-bonded circuits decrease myocardial ischemic damage. An experimental study. Ann Thorac Surg. 1997;63:1701–5.

    Article  CAS  PubMed  Google Scholar 

  6. te-Velthuis H, Baufreton C, Jansen PG, Thijs CM, Hack CE, Sturk A, Wildevuur CR, Loisance DY. Heparin coating of extracorporeal circuits inhibits contact activation during cardiac operations. J Thorac Cardiovasc Surg. 1997;114:117–22.

    Article  CAS  PubMed  Google Scholar 

  7. Moen O, Hogasen K, Fosse E, Dregelid E, Brockmeier V, Venge P, Harboe M, Mollnes TE. Attenuation of changes in leukocyte surface markers and complement activation with heparin-coated cardiopulmonary bypass. Ann Thorac Surg. 1997;63:105–11.

    Article  CAS  PubMed  Google Scholar 

  8. Matsuo M, Kitada H, Iida H, Okamoto T. An experimental study in prolonged use of heparin-coated cardiopulmonary bypass circuits. Jpn J Extra-Copreal Technol. 2000;27:57–9.

    Article  Google Scholar 

  9. Wendel HP, Ziemer G. Coating-techniques to improve the hemocompatibility of artificial devices used for extracorporeal circulation. Eur J Cardiothorac Surg. 1999;16:342–50.

    Article  CAS  PubMed  Google Scholar 

  10. Hazlewood CF, Nichols BL, Chamberlain NF. Evidence for the existence of a minimum of two phases of ordered water in skeletal muscle. Nature. 1969;222:747–50.

    Article  CAS  PubMed  Google Scholar 

  11. Anzai T, Okumura A, Kawaura M, Yokoyama K, Oshiyama H, Kido T, Nojiri C. Evaluation of the biocompatibility of an in vitro test using a poly2 methoxyethylacrylate coated oxygenator. Jinko Zoki. 2000;29:73–9.

    Google Scholar 

  12. Suzuki Y, Daitoku K, Minakawa M, Fukui K, Fukuda IA, Kawaura M, Yokoyama K, Oshiyama H, Kido K, Nojiri C. Poly-2-methoxyethylacrylate-coated bypass circuits reduce activation of coagulation system and inflammatory response in congenital cardiac surgery. Jpn J Artif Organs. 2008;11:111–6.

    Article  CAS  Google Scholar 

  13. Gunaydin S, Farsak B, Kocakulak M, Sari T, Yorgancioglu C, Zorlutuna Y. Clinical performance and biocompatibility of poly (2-methoxyethylacrylate)-coated extracorporeal circuits. Ann Thorac Surg. 2002;74:819–24.

    Article  PubMed  Google Scholar 

  14. Ikuta T, Fujii H, Shibata T, Hattori K, Hirai H, Kumano H, Suehiro S. A new poly-2-methoxyethylacrylate-coated cardiopulmonary bypass circuit possesses superior platelet preservation and inflammatory suppression efficacy. Ann Thorac Surg. 2004;77:1678–83.

    Article  PubMed  Google Scholar 

  15. Suhara H, Sawa Y, Nishimura M, Oshiyama H, Yokoyama K, Saito N, Matsuda H. Efficacy of a new coating material, PMEA, for cardiopulmonary bypass circuits in a porcine model. Ann Thorac Surg. 2001;71:1603–8.

    Article  CAS  PubMed  Google Scholar 

  16. Hazama S, Eishi K, Yamachika S, Noguchi M, Ariyoshi T, Takai H, Odate T, Matsukuma S, Onohara D, Yanatori M. Inflammatory response after coronary revascularization: off-pump versus on-pump (heparin-coated circuits and poly2 methoxyethylacrylate-coated circuits). Ann Thorac Cardiovasc Surg. 2004;10:90–6.

    PubMed  Google Scholar 

  17. Kutay V, Noyan T, Ozcan S, Melek Y, Ekim H, Yakut C. Biocompatibility of heparin-coated cardiopulmonary bypass circuits in coronary patients with left ventricular dysfunction is superior to PMEA-coated circuits. J Card Surg. 2006;21:572–7.

    Article  PubMed  Google Scholar 

  18. Izuha H, Hattori M, Igari T, Wakamatsu D, Watanabe M, Yokoyama H. Changes in platelet aggregation during cardiopulmonary bypass: comparison of poly-2-methoxyethylacrylate and heparin as a circuit coating material. J Artif Organs. 2005;8:41–6.

    Article  CAS  PubMed  Google Scholar 

  19. Saito N, Motoyama S, Sawamoto J. Effects of new polymer-coated extracorporeal circuits on biocompatibility during cardiopulmonary bypass. Artif Organs. 2000;24:547–54.

    Article  PubMed  Google Scholar 

  20. Tanaka M, Motomura T, Kawada M, Anzai T, Kasori Y, Shiroya T, Shimura K, Onishi M, Mochizuki A. Blood compatible aspects of poly(2-methoxyethylacrylate) (PMEA) relationship between protein adsorption and platelet adhesion on PMEA surface. Biomaterials. 2000;21:1471–81.

    Article  CAS  PubMed  Google Scholar 

  21. Muller B, Peri G, Doni A, Torri V, Landmann R, Bottazzi B, Mantovani A. Circulating levels of the long pentraxin PTX3 correlate with severity of infection in critically ill patients. Crit Care Med. 2001;29:1404–7.

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Katsuhiro Hosoyama.

Ethics declarations

Conflicts of interest

Yoshikatsu Saiki received a research grant from Terumo Corporation, Tokyo, Japan. The other authors declare that they have no conflict of interest.

Additional information

K. Hosoyama and K. Ito contributed to this manuscript equally.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Hosoyama, K., Ito, K., Kawamoto, S. et al. Poly-2-methoxyethylacrylate-coated cardiopulmonary bypass circuit can reduce transfusion of platelet products compared to heparin-coated circuit during aortic arch surgery. J Artif Organs 19, 233–240 (2016). https://doi.org/10.1007/s10047-016-0887-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10047-016-0887-8

Keywords

Navigation