1 Introduction

The safety of large-scale structures (e.g., nuclear reactors or aircrafts) attracts considerable attention. In order to improve the safety of such systems, a verification of material properties just after production, as well as systematic material inspection, is required for their parts. Therefore, nondestructive techniques suitable for the study of internal material structure (e.g., industrial radiography or ultrasonic testing) are being developed and improved in order to find defective products or to assess the state of fatigue. Advances in material science reveal new factors or allow understanding the already known ones that influence material properties. Many investigations show that the material surface plays an important role in their mechanical properties [14].

An effective method for improving the properties of the surface layer of machine elements is shot peening. During shot peening, tools (usually balls) strike the machined surface, which results in cold working of the surface layer of workpieces. Due to plastic deformation, the microhardness of the surface layer is increased and residual stresses are generated. Shot peening plays a very important role in increasing the fatigue strength of machine elements made of various materials such as iron, aluminum, titanium, magnesium, and nickel. A beneficial effect of pneumatic shot peening on the fatigue strength for specimens of titanium, aluminum, and magnesium alloys was observed [5]. Furthermore, improvement in the titanium alloy surface layer was studied [6].

It is known that shot peening changes the macroscopic material properties of many materials. The influence of shot peening conditions on Vickers microhardness and residual stresses distributions was described for spring steel [7]. The results of the research on the residual stresses in shot-peened steels and aluminum alloy specimens are presented in [8] (e.g., the maximum compressive residual stress and the depth of the residual stress field). The effectiveness of the fatigue strength improvement depends on the shot peening conditions. Therefore, the influence of impact energy and impact density on the fatigue life of the titanium alloy was investigated [9].

Standard methods for surface layer studying allow characterization of the results of shot peening with sufficient accuracy, but they are destructive (e.g., curvature measurements or the hole-drilling method). In order to make the studies and future industrial inspection focus on the surface layer of the materials, new nondestructive testing (NDT) methods are required. One of such promising NDT methods is positron annihilation lifetime spectroscopy (PALS) [10]. Shot peening leads to an increase in the dislocation density in the surface layer of a workpiece [5]. Its sensitivity to the size and concentration of defects predispose PALS for the study of shot-peened materials. It is confirmed by the results of our previous investigation that PALS is suitable to study the modifications of the steel surface layer [11, 12].

Special portable PALS setups are being developed for industrial application [13]. Development of a portable system implies the use of a standard positron radioactive source, which emits positrons with a broad energy spectrum. The positron energy spectrum and the properties of the studied material determine the positron implantation depth profile, which usually does not overlap the range of changes caused by shot peening. Therefore, PALS response to changes occurring in the sample is influenced by the range of the sensitivity of this method, which has to be taken into account in the interpretation of the results. In the present paper, we study the difference between PALS results obtained for various materials subjected to shot peening. Measurements for samples after various periods of shot peening allow us to examine the change in the structure of the defects during the surface treatment, as made visible by PALS.

2 Materials

Three standard alloys based on iron (C45 steel), aluminum (7075 alloy), and titanium (Ti6Al2Mo2Cr alloy) were chosen for the study due to their applicability in industry. The alloy composition is presented in Table 1. Bar-shaped samples with the dimensions 4 mm × 15 mm × 100 mm were fastened to the bottom of the shot peening machine chamber. The chamber was partially filled by steel bearing balls (6 mm diameter) serving as a peening medium. The burnishing was performed by setting the chamber into a vertical vibratory motion (vibration amplitude 58 mm, vibration frequency 7 Hz). The time of the treatment was set to a particular value between 0.5 and 30 min for each set of samples. As a result, the surface layer of the samples was strain hardened to different degrees due to the impact of the bouncing balls.

Table 1 Composition of C45 steel, 7075 aluminum alloy, and Ti6Al2Mo2Cr titanium alloy

3 Experimental

Positron annihilation lifetime spectra for the alloys under investigation were measured at room temperature by means of a conventional fastslow delayed coincidence spectrometer. A positron source with 300-kBq activity in the form of 22NaCl sealed in 8-µm-thick Kapton foil was used. It was sandwiched between two identical shot-peened surfaces of alloy slim bars and mounted to a detection system. Detection of 1274-keV γ quanta emitted from the source immediately after the β+ decay and giving start signals as well as the detection 511-keV annihilation quanta serving as stop signals was realized by the use of two scintillation detector heads equipped with Photonis XP2020Q photomultipliers and BaF2 ϕ 1.5″ × 1.0″ crystals arranged in 180° geometry. The 100-ns time range of the time-to-amplitude converter (EG&G ORTEC 567) was chosen for the measurements. Then, the channel-width parameter was approximately equal to 0.0119 ns. The effective time resolution (FWHM) of the PALS apparatus also including the nuclear timing electronics and the multichannel analyzer measured for 60Co source did not exceed a value of about 232 ns. The total number of events in a single PALS spectrum recorded at a typical average counting rate of the order of 150 s−1 was above 107 counts. Such statistics were sufficient to obtain reliable results on the basis of numerical analysis of the spectra.

The lifetime spectra were analyzed numerically by the LT program [14]. The model function assumed during the analysis consisted of two exponential components convoluted with a resolution curve approximated by a single Gauss function plus the constant random coincidence background. Positron annihilation in the source envelope was taken into account assuming a single exponential component with the lifetime of 374 ps. The source component intensities, 12.0 % in the C45 steel, 10.9 % in the 7075 aluminum alloy, and 11.5 % in the Ti6Al2Mo2Cr titanium alloy, were calculated [15] taking into account the material composition. Additionally, the lifetime spectra were analyzed by the Bayesian method using the MELT routine [16], which allowed us to find the distribution of the intensities over the dense grid of lifetimes, without assuming the number of components.

Residual stress measurements were performed by the Davidenkov method, which consists in removal of a thin surface layer by chemical etching and measurement of the curvature change in a bar-shaped sample. The depth profile of the residual stresses was calculated using the Davidenkov–Birger equation [17]

$$\sigma (z) = \frac{4E}{{3{l^2}}}\left[ {{{(h - z)}^2}\frac{{{\text{d}}g(z)}}{{{\text{d}}z}} - 4(h - z)g(z) + 2\int\limits_0^z {g(\xi ){\text{d}}\xi } } \right]$$
(1)

where E Young module, l the length of the etched surface, h the thickness of the sample before etching, z the distance from the sample surface, and g(z) the deflection of the sample after the removal of the layer with thickness z.

In order to compare the PALS and residual stress results, knowledge of the implantation depth profile was required. Because no detailed shape of the profile was required and a simple solution applicable in the industry was desired, the implantation depth profile was estimated from the equations [10]:

$$n(z) = \alpha \exp ( - \alpha \cdot z)$$
(2)
$$\alpha = \frac{1}{R} = (16 \pm 1)\frac{d}{{E_{\hbox{max} }^{1,43}}},$$
(3)

where z depth (cm), d average density of the material (g/cm3), E max maximum energy of positrons (MeV), and R positron implantation range.

The fact that positrons from the source are emitted in all the directions is neglected in Eq. 3. However, this causes identical distortion in all the samples, which consists in underestimation of the number of positrons annihilating near the surface. This does not affect the relative differences between the samples. The knowledge of the positron implantation depth profile allowed us to find the residual stress weighted average (over the probability of positron implantation to a particular depth) from the equation:

$${\sigma_w} = \frac{{\int_0^\infty {\left( {n(z) \cdot \sigma (z)} \right)} }}{{\int_0^\infty {n(z)} }} \approx \frac{{\sum\nolimits_{i = 1} {({n_i} \cdot {\sigma_i})} }}{{\sum\nolimits_{i = 1} {n_i} }}.$$
(4)

4 Results and discussion

In all the three materials under investigation and for all the shot peening times, a two-component model was sufficient to obtain a good fit of the model function to the experimental data (χ 2 ≈ 1.1). Both lifetimes are different in each sample, but shot peening does not change them significantly (Fig. 1). The exceptions visible for the short shot peening times have to be considered taking into account that the discrepancies are usually connected with the very low value of the respective intensity. It makes them highly sensitive to systematic errors (e.g., an imprecise determination of source correction). Therefore, any interpretation of these changes is questionable. However, the origin of the particular components in each sample can be deduced, mostly unambiguously, from the average lifetimes (Table 2).

Fig. 1
figure 1

Parameters of two components found in the positron annihilation lifetime spectra of the C45 steel (left), the 7075 aluminum alloy (middle), and the Ti6Al2Mo2Cr titanium alloy (right): lifetimes (τ 1, τ 2), intensity (I 1) of the short-lived component obtained for samples after various times of shot peening. The intensity of the long-lived component can be calculated by subtracting the I 1 value from 100 %. The PALS results were compared to the corresponding residual stress weighted average (σ w )

Table 2 Lifetimes averaged over all shot peening times and their standard deviation for the studied samples

In spite of the large iron contents in the C45 steel, a component with a lifetime close to 100 ps, typical for bulk iron [18, 19], is not present in the spectra. The shortest observed lifetime τ 1 = 151 ps indicates that all positrons are trapped in defects. This dominating component (I 1 > 95 %) can originate from positrons trapped in monovacancies associated with edge dislocation lines in iron [20] or vacancy-solute complexes for steel components (e.g. V–Cr or V–Cu) [21]. Such a result is typical for steels [2224]. The lifetime τ 2 = 407 ps of the long-lived component is longer than that usually observed in deformed steel and iron [19, 24]. Its origin is most probably related to large vacancy clusters consisting of more than 15 vacancies [25].

The lifetime τ 1 = 210 ps of the short-lived component in the 7075 Al alloy is representative for aluminum alloys [2629]. Its value lies clearly below ~250 ps expected for Al monovacancy [18, 25]. A standard explanation for this discrepancy is the contribution of positron annihilation in vacancies bound to different atoms other than the Al ones present in the alloy [2729]. The resulting lifetimes would be too similar to isolate particular components. However, considering the single components with the greatest fraction in the investigated alloy, only positron lifetime in Cu monovacancy is significantly shorter than the lifetime in Al monovacancy. Assuming after others that lifetime in vacancy-solute complex can be estimated based on that related to the bulk material, only the lifetime in V–Cu is short enough to give a contribution, which shortens the lifetime to the value observed in the experiments. Therefore, the observed lifetime would indicate a high probability of positron trapping in the neighborhood of Cu atoms. On the other hand, there is a simpler interpretation of the results. Shorter lifetimes ~225 and ~190 ps are expected for a single vacancy or a jog on the dislocation line and for dislocation loops, respectively [30]. Their contributions can be more essential than the ones from the vacancy-solute complexes. The second component lifetime τ 2 = 350 ps is characteristic for much smaller vacancy clusters (~6 vacancies) than the ones found in the steel [25].

There is a shortage of both theoretical and experimental data about the lifetimes in Ti alloys with high titanium contents. Similar to the discussed steel and the Al alloy, the shortest lifetime observed in Ti6Al2Mo2Cr samples is longer than the Ti bulk lifetime (140–150 ps) and shorter than the lifetime of positrons trapped in monovacancies (220–240 ps) calculated or observed in high-purity Ti or its alloys with contents close to 50 % [18, 3133]. As in previous cases, the observed lifetime can be attributed to vacancies on dislocation lines or in the neighborhood of alloy components other than the Ti atoms. There also exists a possibility that the layer of titanium oxides on the sample surface gives contribution with the lifetime of 190–200 ps [34]. It is probably impossible to distinguish between all these contributions with similar lifetimes, and in consequence, the mean lifetime of 189 ps is observed. The second component indicates that vacancy clusters are also present in the Ti alloy.

The analysis of the origin of the components in the investigated samples, which was presented above, allows us to explain the character of changes caused by shot peening from positron lifetime measurement (Fig. 1).

The most pronounced and systematic change is visible in the relative intensities of both lifetime components. In general, the intensity of the first component (I 1) increases with the shot peening time in the steel and the Al alloy. An exception from the monotonic rise is a discontinuity visible for I 1 in spectra after 5 and 10 min of shot peening in the case of the Al alloy and, to a lesser degree, in spectra after 15 and 30 min of shot peening in the case of the steel. Nevertheless, it is hard to determine whether these results reflect a sample structure change or random dispersion of the results. This second possibility is supported by the lifetime values, i.e., the difference between τ 2 and τ 1 is larger if I 1 values lie above the observed trend lines and vice versa. An opposite tendency in the I 1 changes (i.e., a decrease with the rise in the shot peening time) is observed in the case of the Ti alloy.

In order to find the cause of the difference between the shot peening influence on positron lifetime spectra in the steel or the Al alloy and Ti alloy, the PALS results are compared to the average of residual stress (σ w ) weighted over the positron implantation profile (Fig. 1). The weighted average of residual stresses generally decreases (i.e., compressive residual stresses, which are denoted as negative values in the Davidenkov method, increase) with the increasing shot peening time, and there is no qualitative difference between the studied samples. A change in the decreasing tendency can be found in the steel, which was processed for more than 20 min. This result is confirmed by the previous findings obtained for different samples made of the same material [11]. It also confirmed that the decrease in I 1 between 15 and 30 min was not caused by a statistical dispersion of the results. However, it was not found during the previous studies of the same kind. There is no confirmation of I 1 discontinuity in the Al alloy. The residual stress studies suggest that further changes in the surface layer of the material penetrated by positrons are insignificant for a shot peening time longer than 5 min. It is worth noticing that the σ w values are about ten times smaller in the Al alloy than in the other studied materials. The simplest relation between σ w and the shot peening time is found for the Ti alloy giving no support for the reversed I 1 tendency. This proves that taking into account the weighted average value of the residual stress only is insufficient. Therefore, a more detailed study of the residual stress depth distribution is required.

The comparison between residual stress depth distributions and positron implantation profiles estimated from Eq. 2 is presented in Fig. 2 for all the studied samples. The residual stress depth distributions are u-shaped for all of the samples. They are very similar for the steel and the Ti alloy. Both distributions start with a large negative value on the surface indicating existence of compressive residual stresses, a decrease within 100 μm below the surface, and then an increase to about zero in the range of another several hundred micrometers. For both the steel and Ti alloy samples, an increase in the shot peening time results in a shift of the distributions toward negative values almost without changing their shape. The distribution in the steel is only a little widened, while the one in the Ti alloy becomes slightly narrower. The residual stress depth distribution in the Al alloy is quite different. It starts from positive values on the surface, which indicate tensile stresses. The layer where residual stress decreases is much deeper, whereas the lowest value lies 4–5 times above analogical values in the steel or the Ti alloy. Furthermore, the changes caused by the increase in the shot peening time are much smaller compared with the other samples, although the changed direction seems to agree with the ones observed in other materials.

Fig. 2
figure 2

Depth distribution of residual stresses (σ) in the C45 steel (left), the 7075 aluminum alloy (middle), and the Ti6Al2Mo2Cr (right) after about 1 (solid line), 5 (dashed line), and 30 (dot-dash line) minutes of shot peening. The distribution is compared to the positron implantation depth profile (n) in the particular materials. Two vertical dotted lines at the smaller and larger depths represent approximate ranges below which 50 and 99 % of positrons annihilate, respectively

The positron implantation range is the smallest in the steel [R = 33(2) μm], about two times greater in the Ti alloy [R = 58(4) μm], and three times greater in the Al alloy [R = 95(8) μm]. On the other hand, the minimum of residual stress distribution (i.e., the greatest compressive residual stress) is roughly at the same depth in both the steel and the Ti alloy (50–100 μm) but at about three times greater depth (200–300 μm) in the Al alloy. Thus, positrons penetrate mostly the surface layer where residual stress decreases with depth in the steel and the Al alloy, while in the Ti alloy, they annihilate almost in the whole layer where residual stress is present. This difference between the Ti alloy and the other materials allows us to explain the opposite inclination of I 1 changes with the increasing shot peening time for this material.

The appearance and the increase in residual stresses caused by shot peening testify that the distribution of the defects in the samples becomes depth dependent. The concentration of defects of a particular kind and size, which are present in the material, changes with the distance from the sample surface [22]. Due to the exponential shape of the positron implantation profile, there is a different contribution to the intensity of the positron component from the defects near the sample surface in comparison with the same defects present in the depth of the sample. Therefore, the change in intensity can be a result of either the change in the total concentration of the defects attributed to this component or the change in the concentration profile in the direction perpendicular to the sample surface. Taking into account this findings for the present results, we can conclude that the changes in I 1 observed in the studied samples do not necessarily prove that the total concentration ratio of the smaller free volumes (monovacancies) to the larger ones (vacancy clusters) increases in the steel and the Al alloy, but decreases in the Ti alloy. Another possibility is that due to the shot peening, large defects are moved away from the surface, while most of the small ones remain near the surface. Thus, the dissimilarity of the PALS results for the Ti alloy may be a result of a greater scope of data collected in this material rather than a different consequence of shot peening. Even though the residual stress measurement does not allow distinguishing between the sizes of the defects, the difference between the scope of the positron study in the Ti alloy and the other alloys can be detected by this method. The contribution of the compressive residual stress present virtually above the positron range (available only to 1 % of positrons) to the whole residual stress was estimated from its depth distribution (Fig. 3). With the time of shot peening, the contribution clearly increases in the steel and Al alloy, while no such effect is observed in the Ti alloy. The interpretation presented previously is supported by the fact that there is no other evolution of the residual stresses in the Ti alloy compared with the other material, which could be expected if the distribution of the defects is substantially different. Thus, if shot peening influences the defect distribution in all the samples in a similar way, we can describe the mechanism of the defect formation in greater detail taking advantage of the differences in the positron range. Hence, we can determine not only that shot peening causes formation of a higher number of large defects in comparison with small ones, as observed in the Ti alloy, but also that the larger defects are formed far from the surface, beyond the positron ranges in the steel and the Al alloy samples.

Fig. 3
figure 3

Relative contribution of the compressive residual stress (σ Σ ) above the range below which 99 % of positrons annihilate (marked in Fig. 2) for the C45 steel (left), the 7075 aluminum alloy (middle), and the Ti6Al2Mo2Cr (right) samples after various times of shot peening. The negative values mean predominance of the tensile residual stress

Other information about the size distribution of defects can be obtained from the analyses of the PALS spectra performed by MELT. Such analyses were performed in order to determine whether the dispersion of the results observed in the Al alloy was dependent on the analysis method. This aim could not be achieved because the lifetime histograms obtained from MELT showed very wide lifetime distributions (Fig. 4). Such distributions do not allow separation of the two components, which does not let us determine their intensities. However, an interesting dependence between a lifetime distribution and a shot peening time is visible in the histograms. The positron lifetimes are widely distributed between 170 and 300 ps forming virtually one asymmetric peak before shot peening. However, the processing causes formation of two well-separated peaks instead of an initial one. The cause of such a change is probably systematic disappearance of the defects, in which the positron lifetime is about 230 ps, in consequence of the shot peening. The lifetime value allows us to identify these defects as monovacancies (250 ps) or monovacancies on the dislocation line (225 ps). Keeping in mind the previous findings, we have to notice that this effect is observed only close to the surface, and the changes may be different in the deeper layers of the sample. No similar changes were found in the other samples.

Fig. 4
figure 4

Histograms of intensities on the dense lifetime grid obtained by MELT for the C45 steel (left), the 7075 aluminum alloy (middle), and Ti6Al2Mo2Cr (right) for an unburnished sample and after the time of shot peening, which is specified in the figure

The MELT results presented in Fig. 4 show a systematic shift toward the short lifetimes in comparison with the LT results. The cause of such discrepancy is the long-lived and low-intensity component found by MELT, the example of which is shown in Table 3 for samples that were shot-peened for about 10 min. The origin of the component of such low intensity can be either positron annihilation in microcracks, which has already been observed in steels [12], or the undesired distortion of the spectra, e.g., the detection of scattered annihilation radiation. An attempt to take this component into account during LT analysis results in better agreement with the MELT results, but also the uncertainties of the parameters become 2–3 times larger, while χ 2 decreases only by 2–3 %. Therefore, only the two-component LT analysis allows drawing conclusions about the changes caused by shot peening.

Table 3 Lifetimes and the intensities of the shot-peened for 10 min samples (8 min in the case of the titanium alloy) obtained using two different methods for spectra analysis provided by LT and MELT

5 Conclusions

Analyzing the PALS spectra for the studied samples in terms of two discrete (i.e., exponential) positron lifetime components is definitely an oversimplification. The MELT results show that at least three discrete components are required to find what kinds of defects are responsible for the changes observed in the spectra of the studied alloys. Unfortunately, such a high number of components with close lifetimes cannot be distinguished using the standard methods of spectra analysis. Even for high-statistic spectra, keeping a reasonable uncertainty in the measured values is impossible. Nevertheless, a two-component approximation of the small and large defects allows us to find an interesting relationship between the shot peening time and the component intensities.

A discrepancy between the steel and the Al alloy, where the intensity of the short-lived, dominating component increases with the shot peening time and the Ti alloy shows an opposite relation, is clearly visible. From the fact that the discrepancy is not reflected by the macroscopic residual stresses, we conclude that this effect is related to PALS properties. The positron range in relation to the depth of the structure changes caused by shot peening seems to be the best explanation for the observed phenomenon. Additional conclusions about the defect distribution can be found taking into consideration the positron range. Hence, we deduce that shot peening causes migration of large defects (i.e., vacancy clusters) away from the surface, while only smaller ones (i.e., monovacancies or vacancies on dislocation lines) remain close to the surface. Because all positrons are trapped in defects, it is possible to observe relative changes only.

It would be interesting to verify the findings presented above by the use of a variable energy positron beam, but currently there is no setup that would allow us to obtain monoenergetic positrons with high-enough energy to perform this experiment. It is also possible to perform analogical measurements removing subsequent layers from the sample surface, but there is no guarantee that this process will not influence the sample structure. An interesting alternative for the positron source is 44Ti, which emits positrons with an about three times higher energy than 22Na. If our considerations concerning the positron range are correct, a measurement performed with a 44Ti source should show a decrease in the short-lived intensity component also in steel and the Al alloy.