Abstract
In this study, a sensitive and facile method with wide linear range and low detection limit for detecting hydrogen sulfide in rat brain microdialysate was developed. The design of the sensor is based on the competitive binding reaction principle, in which cysteine was self-assembly immobilized on the surface of gold electrode, and then the Cu2+ as the electrochemical probe was anchored to the cysteine film through coordination bonding with carboxyl (−COOH) and amino group (−NH2) to form the Cu2+/Cys/Au electrode. The Cu2+/Cys/Au electrode can serve as an electrochemical H2S sensor through a ligand exchange reaction, which may come from the greater affinity of H2S than cysteine to the gold surface due to a steric hindrance reason. The hydrogen sulfide cuts off the S-Au bonds between cysteine and Au electrode and leads to the Cu2+ drop off from electrode, resulting in a decrease in the redox signal of Cu2+, thereby creating a current that is indirectly proportional to the logarithm of the concentration of H2S dissolved at the sensor surface. The current response, i.e., signal output, is in wide linearity to logarithm of the concentration of H2S in the range of 0.01–100.0 μM with ΔI/μA = 0.0857 lgCH2S(nM) +0.124 and very low detection limit 5 nM (S/N = 3). The assay demonstrated here is highly selective with respect to alleviating the interference of other thiol-containing species such as glutathione (GSH), homocysteine (Hcy), and cysteine commonly existing in the brain. The basal level of H2S in the microdialysate from the hippocampus of rats is determined to be around 8.6 ± 3.2 μM. The method demonstrated here is facile but reliable and durable and is envisaged to be applicable to understanding the chemical essence involved in physiological and pathological events associated with H2S.
Similar content being viewed by others
References
Abe K, Kimura H. The possible role of hydrogen sulfide as an endogenous neuromodulator. J Neurosci. 1996;16:1066–71.
Wang R. Physiological implications of hydrogen sulfide: a whiff exploration that blossomed. Physiol Rev. 2012;92:791–896.
Yang GD, Wu LY, Jiang B, Yang W, Qi JS, Cao K, et al. H2S as a physiologic vasorelaxant: hypertension in mice with deletion of cystathionine γ-lyase. Science. 2008;322:587–90.
Antonucci MU, Mocco J, Bennett JA. New insight into transient contrast enhancement on computed tomography after endovascular treatment of stroke. Interv Neuroradiol. 2012;18(3):303–8.
Giovanelli D, Lawrence NS, Jiang L, Jones TGJ, Compton RG. Amperometric determination of sulfide at a pre-oxidised nickel electrode in acidic media. Analyst. 2003;128(2):173–9.
Wintner EA, Deckwerth TL, Langston W, Bengtsson A, Leviten D, Hill P, et al. A monobromobimane-based assay to measure the pharmacokinetic profile of reactive sulphide species in blood. British Journal of Pharmacology. Brit J Pharmacol. 2010;160:941–57.
Liu C, Pan J, Li S, Zhao Y, Wu LY, Berkman CE, et al. Capture and visualization of hydrogen sulfide by a fluorescent probe. Angew Chem Int Edit. 2011;50(44):10327–9.
DeLeon ER, Stoy GF, Olson KR. Passive loss of hydrogen sulfide in biological experiments. Anal Biochem. 2012;421(1):203–7.
Jarosz AP, Yep T, Mutus B. Microplate-based colorimetric detection of free hydrogen sulfide. Anal Chem. 2013;85(7):3638–43.
Kong H, Ma ZR, Wang S, Gong XY, Zhang SC, Zhang XR. Hydrogen sulfide detection based on reflection: from a poison test approach of ancient china to single-cell accurate localization. Anal Chem. 2014;86(15):7734–9.
Zhu XC, Xu L, Wu TB, Xu AQ, Zhao MP, Liu SR. Continuous monitoring of bisulfide variation in microdialysis effluents by on-line droplet-based microfluidic fluorescent sensor. Biosens Bioelectron. 2014;55:438–45.
Gu FD, Zhou XY, Zhu XC, Zhao MP, Hao J, Yu P, et al. In vivo and continuous measurement of bisulfide in the hippocampus of rat’s brain by an on-line integrated microdialysis/droplet-based microfluidic system. Analyst. 2015;140(11):3814–9.
Yue XX, Zhu ZY, Zhang MN, Ye ZQ. Reaction-based turn-on electrochemiluminescent sensor with a ruthenium(II) complex for selective detection of extracellular hydrogen sulfide in rat brain. Anal Chem. 2015;87(3):1839–45.
Sathyadevi P, Chen YJ, Wu SC, Chen YH, Wang YM. Reaction-based epoxide fluorescent probe for in vivo visualization of hydrogen sulfide. Biosens Bioelectron. 2015;68:681–7.
Li X, Cheng J, Gong YL, Yang B, Hu YZ. Mapping hydrogen sulfide in rats with a novel azo-based fluorescent probe. Biosens Bioelectron. 2015;65:302–6.
Ding SS, Feng GQ. Smart probe for rapid and simultaneous detection and discrimination of hydrogen sulfide, cysteine/homocysteine, and glutathione. Sensor Actuat B-Chem. 2016;235:691–7.
Usha SP, Mishra SK, Gupta BD. Fiber optic hydrogen sulfide gas sensors utilizing ZnO thin film/ZnO nanoparticles: a comparison of surface plasmon resonance and lossy mode resonance. Sensor Actuat B-Chem. 2015;218:196–204.
Kneer J, Knobelspies S, Bierer B, Wöllenstein J, Palzer S. New method to selectively determine hydrogen sulfide concentrations using CuO layers. Sensor Actuat B-Chem. 2016;222:625–31.
Fu TX. Sensing properties and mechanism of gas sensor for H2S and NO2 based on [Cu5(bipyO2)6Cl8]Cl2. Sensor Actuat B-Chem. 2007;123(2):1113–9.
Thompson M, Lawrence NS, Davis J, Li J, Jones TGJ, Compton RG. A reagentless renewable N, N′-diphenyl-p-phenylenediamine loaded sensor for hydrogen sulfide. Sensor Actuat B-Chem. 2002;87:33–40.
Li DP, Zhang JF, Cui J, Ma XF, Liu JT, Miao JY, et al. A ratiometric fluorescent probe for fast detection of hydrogen sulfide and recognition of biological thiols. Sensor Actuat B-Chem. 2016;234:231–8.
Bennett JA, Pander JE, Neiswonger MA. Investigating the viability of electrodeposited vanadium pentoxide as a suitable electrode material for in vivo amperometric hydrogen sulfide detection. J Electroanal Chem. 2011;654(1–2):1–7.
Eckert W, Frevert T, Trüper HG. A new liquid-junction free probe for the in situ determination of pH, pH2S and redox values. Water Res. 1990;24(11):1341–6.
Qian Q, Deng JJ, Wang DL, Yang LF, Yu P, Mao LQ. Aspartic acid-promoted highly selective and sensitive colorimetric sensing of cysteine in rat brain. Anal Chem. 2012;84(21):9579–84.
Lin YQ, Hu LL, Li LB, Wang KQ, Ji YF, Zou H. Electrochemical determination of pyrophosphate at nanomolar levels using a gold electrode covered with a cysteine nanofilm and based on competitive coordination of Cu(II) ion to cysteine and pyrophosphate. Microchim Acta. 2015;182(11–12):2069–75.
Marino N, Ikotun OF, Julve M, Lloret F, Cano J, Doyle RP. Pyrophosphate-mediated magnetic interactions in Cu(II) coordination complexes. Inorg Chem. 2011;50:378–89.
Lin YQ, Zhu NN, Yu P, Su L, Mao LQ. Physiologically relevant online electrochemical method for continuous and simultaneous monitoring of striatum flucose and lactate following global cerebral ischemia/reperfusion. Anal Chem. 2009;81:2067–74.
Zhang ZY, Chen ZP, Wang SS, Qu CL, Chen LX. On-site visual detection of hydrogen sulfide in air based on enhancing the stability of gold nanoparticles. ACS Appl Mater Int. 2014;6:6300–7.
Zhang J, Xu X, Yang X. Highly specific colorimetric recognition and sensing of sulfide with glutathione-modified gold nanoparticle probe based on an anion-for-molecule ligand exchange reaction. Analyst. 2012;137:1556–8.
Shirsat MD, Bangar MA, Deshusses MA, Myung NV, Mulchandani A. Polyaniline nanowires-gold nanoparticles hybrid network based chemiresistive hydrogen sulfide sensor. Appl Phys Lett. 2009;94(8):083502.
Deng JJ, Yu P, Yang LF, Mao LQ. Competitive coordination of Cu2+ between cysteine and pyrophosphate ion: toward sensitive and selective sensing of pyrophosphate ion in synovial fluid of arthritis patients. Anal chem. 2013;85(4):2516–22.
Lawrence NS, Deo RP, Wang J. Electrochemical determination of hydrogen sulfide at carbon nanotube modified electrodes. Anal Chim Acta. 2004;517(1–2):131–7.
Acknowledgments
We gratefully acknowledge financial support from the National Natural Science Foundation of China (21575090), Beijing Municipal Natural Science Foundation (2162009), and Youth Talent Project of the Beijing Municipal Commission of Education (CIT&TCD201504072).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Rights and permissions
About this article
Cite this article
Li, B., Li, L., Wang, K. et al. Ultrasensitive and facile electrochemical detection of hydrogen sulfide in rat brain microdialysate based on competitive binding reaction. Anal Bioanal Chem 409, 1101–1107 (2017). https://doi.org/10.1007/s00216-016-0030-y
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00216-016-0030-y