Skip to main content
Log in

Squeaking in Metal-on-Metal Hip Resurfacing Arthroplasties

  • Symposium: Complications of Hip Arthroplasty
  • Published:
Clinical Orthopaedics and Related Research®

Abstract

Background

While most reports of audible squeaking in total hip arthroplasty (THA) have focused on ceramic bearings, squeaking can occur in metal-on-metal bearings and may be an important clinical complication to consider during patient followup.

Questions/purposes

We retrospectively identified 10 patients with squeaking metal-on-metal hip resurfacings.

Methods

This study reports acetabular inclination angles and patient satisfaction, and describes two patients with squeaking resurfacings: one was revised and the other is pending revision. The minimum followup time in all 10 patients was 6 months (mean, 52 months; range, 6 to 79 months).

Results

The average time to onset was 11 months (range, 3–22 months). Hips started squeaking after bending, heavy activity, or prolonged periods of walking and the squeaking resolved within a week in all episodes. All hips except one were in the range of 45° ± 10° inclination (median, 48°). One patient who reported squeaking at 6 weeks was revised 6 years postoperatively for a cystic mass. A second patient, now 76 months postoperative, who reports squeaking weekly after walking long distances, is scheduled for revision due to high serum metal ion levels and osteolysis in DeLee and Charnley Zone 1 of the acetabulum.

Conclusions

We cannot conclude whether these complications are related to squeaking. Most patients with squeaking hip resurfacings do not appear to have an adverse response or clinical complication after 6 years. Squeaking in hip resurfacings is a short-term episode that could not be related to acetabular component inclination or decreased patient satisfaction.

Level of Evidence

Level II, prognostic study. See Guidelines for Authors for a complete description of levels of evidence.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1A–D
Fig. 2A–B

Similar content being viewed by others

References

  1. Back DL, Dalziel R, Young D, Shimmin A. Early results of primary Birmingham hip resurfacings. An independent prospective study of the first 230 hips. J Bone Joint Surg Br. 2005;87:324–329.

    Article  CAS  PubMed  Google Scholar 

  2. Bengs BC, Sangiorgio SN, Ebramzadeh E. Less range of motion with resurfacing arthroplasty than with total hip arthroplasty: in vitro examination of 8 designs. Acta Orthop. 2008;79:755–762.

    Article  PubMed  Google Scholar 

  3. Callaghan JJ, Salvati EA, Pellicci PM, Wilson PD, Jr, Ranawat CS. Results of revision for mechanical failure after cemented total hip replacement, 1979 to 1982. A two to five-year follow-up. J Bone Joint Surg Am. 1985;67:1074–1085.

    CAS  PubMed  Google Scholar 

  4. Campbell P, Shimmin A, Walter L, Solomon M. Metal sensitivity as a cause of groin pain in metal-on-metal hip resurfacing. J Arthroplasty. 2008;23:1080–1085.

    Article  PubMed  Google Scholar 

  5. Charnley J. Low Friction Arthroplasty of the Hip: Theory and Practice. New York, NY: Springer-Verlag; 1979.

    Google Scholar 

  6. De Haan R, Pattyn C, Gill HS, Murray DW, Campbell PA, De Smet K. Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. J Bone Joint Surg Br. 2008;90:1291–1297.

    Article  PubMed  Google Scholar 

  7. de Nies F, Fidler MW. Visual analog scale for the assessment of total hip arthroplasty. J Arthroplasty. 1997;12:416–419.

    Article  PubMed  Google Scholar 

  8. De Smet K, De Haan R, Calistri A, Campbell PA, Ebramzadeh E, Pattyn C, Gill HS. Metal ion measurement as a diagnostic tool to identify problems with metal-on-metal hip resurfacing. J Bone Joint Surg Am. 2008;90 Suppl 4:202–208.

    Article  PubMed  Google Scholar 

  9. DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20–32.

    PubMed  Google Scholar 

  10. Ebied E, Journeaux S. Metal-on-metal hip resurfacing. Curr Orthop. 2002;16:420–425.

    Article  Google Scholar 

  11. Heisel C, Streich N, Krachler M, Jakubowitz E, Kretzer JP. Characterization of the running-in period in total hip resurfacing arthroplasty: an in vivo and in vitro metal ion analysis. J Bone Joint Surg Am. 2008;90 Suppl 3:125–133.

    Article  PubMed  Google Scholar 

  12. Hing CB, Back DL, Bailey M, Young DA, Dalziel RE, Shimmin AJ. The results of primary Birmingham hip resurfacings at a mean of five years. An independent prospective review of the first 230 hips. J Bone Joint Surg Br. 2007;89:1431–1438.

    Article  CAS  PubMed  Google Scholar 

  13. Hing CB, Young DA, Dalziel RE, Bailey M, Back DL, Shimmin AJ. Narrowing of the neck in resurfacing arthroplasty of the hip: a radiological study. J Bone Joint Surg Br. 2007;89:1019–1024.

    CAS  PubMed  Google Scholar 

  14. Jarrett CA, Ranawat AS, Bruzzone M, Blum YC, Rodriguez JA, Ranawat CS. The squeaking hip: a phenomenon of ceramic-on-ceramic total hip arthroplasty. J Bone Joint Surg Am. 2009;91:1344–1349.

    Article  PubMed  Google Scholar 

  15. Keurentjes JC, Kuipers RM, Wever DJ, Schreurs BW. High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings. Clin Orthop Relat Res. 2008;466:1438–1443.

    Article  CAS  PubMed  Google Scholar 

  16. Lusty PJ, Walter WL, Young D. Posterior and posteroinferior approaches. In: Hozack W, Parvizi J, Bender B, eds. Surgical Treatment of Hip Arthritis: Reconstruction, Replacement and Revision. Philadephia, PA: Elsevier; 2010.

    Google Scholar 

  17. Mai K, Verioti C, Ezzet KA, Copp SN, Walker RH, Colwell CW, Jr. Incidence of ‘squeaking’ after ceramic-on-ceramic total hip arthroplasty. Clin Orthop Relat Res. 2010;468:413–417.

    Article  PubMed  Google Scholar 

  18. Pandit H, Glyn-Jones S, McLardy-Smith P, Gundle R, Whitwell D, Gibbons CL, Ostlere S, Athanasou N, Gill HS, Murray DW. Pseudotumours associated with metal-on-metal hip resurfacings. J Bone Joint Surg Br. 2008;90:847–851.

    Article  CAS  PubMed  Google Scholar 

  19. Restrepo C, Parvizi J, Kurtz SM, Sharkey PF, Hozack WJ, Rothman RH. The noisy ceramic hip: is component malpositioning the cause? J Arthroplasty. 2008;23:643–649.

    Article  PubMed  Google Scholar 

  20. Rodriguez JA. The squeaking hip is a multifactorial concern. Orthopaedics Today. 2008;28:92.

    Google Scholar 

  21. Rosneck J, Klika A, Barsoum W. A rare complication of ceramic-on-ceramic bearings in total hip arthroplasty. J Arthroplasty. 2008;23:311–313.

    Article  PubMed  Google Scholar 

  22. Toni A, Traina F, Stea S, Sudanese A, Visentin M, Bordini B, Squarzoni S. Early diagnosis of ceramic liner fracture. Guidelines based on a twelve-year clinical experience. J Bone Joint Surg Am. 2006;88 Suppl 4:55–63.

    Article  PubMed  Google Scholar 

  23. Tuke MA, Scott G, Roques A, Hu XQ, Taylor A. Design considerations and life prediction of metal-on-metal bearings: the effect of clearance. J Bone Joint Surg Am. 2008;90 Suppl 3:134–141.

    Article  PubMed  Google Scholar 

  24. Walter LR, Marel E, Harbury R, Wearne J. Distribution of chromium and cobalt ions in various blood fractions after resurfacing hip arthroplasty. J Arthroplasty. 2008;23:814–821.

    Article  PubMed  Google Scholar 

  25. Walter WL, O’Toole GC, Walter WK, Ellis A, Zicat BA. Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation. J Arthroplasty. 2007;22:496–503.

    Article  PubMed  Google Scholar 

  26. Walter WL, Waters TS, Gillies M, Donohoo S, Kurtz SM, Ranawat AS, Hozack WJ, Tuke MA. Squeaking hips. J Bone Joint Surg Am. 2008;90 Suppl 4:102–111.

    Article  PubMed  Google Scholar 

  27. Willert HG, Buchhorn GH, Gobel D, Koster G, Schaffner S, Schenk R, Semlitsch M. Wear behavior and histopathology of classic cemented metal on metal hip endoprostheses. Clin Orthop Relat Res. 1996(329 Suppl):S160–S186.

Download references

Acknowledgment

We thank Paul Thornton-Bott for his assistance in this study.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to William L. Walter MBBS, FRACS (Orth), PhD (Surg).

Additional information

One of the authors (AR) certifies that he or she has or may receive payments or benefits from a commercial entity (Finsbury Orthopaedics Ltd) related to this work. One or more of the authors (CE, WLW) have received funding from Finsbury Orthopaedics Ltd and Friends of the Mater Foundation.

Each author certifies that his or her institution approved the human protocol for this investigation, that all investigations were conducted in conformity with ethical principles of research, and that informed consent for participation in the study was obtained.

This work was performed at the Specialist Orthopaedic Group, North Sydney, Australia.

About this article

Cite this article

Esposito, C., Walter, W.L., Campbell, P. et al. Squeaking in Metal-on-Metal Hip Resurfacing Arthroplasties. Clin Orthop Relat Res 468, 2333–2339 (2010). https://doi.org/10.1007/s11999-010-1344-2

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11999-010-1344-2

Keywords

Navigation