Skip to main content
Log in

Dimensional contraction by principal component analysis as preprocessing for independent component analysis at MCG

  • Original Article
  • Published:
Biomedical Engineering Letters Aims and scope Submit manuscript

Abstract

We propose a noise reduction method for magnetocardiograms (MCGs) based on independent component analysis (ICA). ICA is useful to separate the noise and signal components, but ICA-based automatic noise reduction faces two main difficulties: the dimensional contraction process applied after the principal component analysis (PCA) used for preprocessing, and the component selection applied after ICA. The results of noise reduction vary among people, because these two processes typically depend on personal qualitative evaluations of the obtained components. Therefore, automatic quantitative ICA-based noise reduction is highly desirable. We will focus on the first difficulty, by improving the index used in the dimensional contraction process. The index used for component ordering after PCA affects the accuracy of separation obtained with ICA. The contribution ratio is often used as an index. However, its efficacy is highly dependent on the signal-to-noise ratio (SNR) it unsuitable for automation. We propose a kurtosis-based index, whose efficacy does not depend on SNR. We compare the two decision indexes through simulation. First, we evaluate their preservation rate of the MCG information after dimensional contraction. In addition, we evaluate their effect on the accuracy of the ICA-based noise reduction method. The obtained results show that the kurtosis-based index does preserve the MCG signal information through dimensional contraction, and has a more consistent behavior when the number of components increases. The proposed index performs better than the traditional index, especially in low SNRs. As such, it paves the way for the desired noise reduction process automation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  1. Kobayashi K, Oyamada K, Yoshizawa M, Uchikawa Y. Environmental magnetic noise rejection using independent component analysis for MCG. J Magn Soc Jpn. 2010;34:156–60.

    Article  Google Scholar 

  2. Oyamada K, Kobayashi K, Yoshizawa M, Uchikawa Y. Study of parameter decision for a noise rejection method using ICA for a magnetocardiogram. J Magn Soc Jpn. 2010;34:146–50.

    Article  Google Scholar 

  3. Nadal J-P, Korutcheva E, Aires F. Blind source processing in the presence of weak sources. Neural Netw. 2000;13(6):589–96.

    Article  Google Scholar 

  4. Hyvärinen A, Karhunen J, Oja E. Independent component analysis. New York: Wiley; 2001.

    Book  Google Scholar 

  5. DeCarlo LT. On the meaning and use of kurtosis. Phycol Methods. 1997;2(3):292–307.

    Google Scholar 

Download references

Acknowledgements

This work was supported by the Japan Society for the Promotion of Science KAKENHI (Grants-in-Aid for Scientific Research (C)), Grant Number JP26350535. The authors declare no competing financial interests.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. Iwai.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Iwai, M., Kobayashi, K. Dimensional contraction by principal component analysis as preprocessing for independent component analysis at MCG. Biomed. Eng. Lett. 7, 221–227 (2017). https://doi.org/10.1007/s13534-017-0024-5

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s13534-017-0024-5

Keywords

Navigation