Maintaining the accuracy of the 60Co calibration service at the ARPANSA post source replacement in 2010

  • Technical Paper
  • Published:
Australasian Physical & Engineering Sciences in Medicine Aims and scope Submit manuscript

Abstract

The Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) maintains a 60Co teletherapy source primarily for the calibration of therapy dosemeters. The source and encapsulating head were replaced in early 2010 with an Eldorado 78 head and new 60Co source. In this article we present the results of ongoing accuracy and stability measurements since the replacement. A number of formal and informal indirect comparisons have been carried out with laboratories holding primary and secondary standards for 60Co. ARPANSA chambers have also been calibrated at international primary standard laboratories allowing comparison of calibration coefficients and thus 60Co absorbed dose standards. 60Co calibration coefficients supplied by manufacturers of chambers were compared to those measured at the ARPANSA when this calibration was traceable to a primary standard. ARPANSA also participates in an annual international mailed dosimetry audit conducted by the International Atomic Energy Agency. The results thus far demonstrate that the absorbed doses to water delivered by the new ARPANSA 60Co source are consistent with international doses within the stated uncertainties.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Australian Institute of Health and Welfare (2014) Radiation oncology areas of need: cancer incidence projections 2014–2024 [Cancer series no. 85. (Cat. no. CAN 82)]. AIHW, Canberra

    Google Scholar 

  2. Barton M, Jacob S, Shafiq J, Wong KHW, Delaney G, Hanna T (2013) Review of optimal radiotherapy utilisation rates. Ingham Institute for Applied Medical Research, Liverpool

    Google Scholar 

  3. Ramanathan G, Harty P, Wright T, Lye J, Butler D, Webb D, Huntley R (2014) The Australian Primary Standard for absorbed dose to water (graphite calorimeter). ARPANSA Technical Report TR169

  4. Lye J, Butler D, Franich R, Harty P, Oliver C, Ramanathan G, Webb D, Wright T (2013) Direct MC conversion of absorbed dose to graphite to absorbed dose to water for 60Co radiation. Radiat Prot Dosim 155(1):100–109

    Article  CAS  Google Scholar 

  5. Kessler C, Burns DT, Allisy-Roberts PJ, Butler D, Lye J, Webb D (2012) Comparison of the standards for absorbed dose to water of the ARPANSA and the BIPM for 60Co gamma radiation. Metrologia 49:06009

    Article  Google Scholar 

  6. Shimizu M, Morishita Y, Kato M, Tanaka T, Kurosawa T, Takata N, Saito N, Ramanathan G, Harty P, Oliver C, Wright T, Butler D (2014) Comparison of the NMIJ and the ARPANSA standards for absorbed dose to water in the high-energy photon beams. Radiat Prot Dosim. doi:10.1093/rpd/ncu272

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Chris Oliver.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Oliver, C., Butler, D., Webb, D. et al. Maintaining the accuracy of the 60Co calibration service at the ARPANSA post source replacement in 2010. Australas Phys Eng Sci Med 38, 325–330 (2015). https://doi.org/10.1007/s13246-015-0338-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s13246-015-0338-5

Keywords

Navigation