Hybrid flexural components: Testing pre-stressed steel and GFRP bars together as reinforcement for flexural members

  • Research Article
  • Published:
Frontiers of Structural and Civil Engineering Aims and scope Submit manuscript

Abstract

Concrete members historically have used either pre-stressed steel or steel bars. In recent years there has been an increased interest in the use of fiber reinforced polymer (FRP) materials. However, the flexure behavior of a hybrid system reinforced by the combination of pre-stressed steel and glass fiber reinforced (GFRP) is still relatively unknown. The purpose of this work is to study this. Two slabs of 100 and 150-millimeter thickness, with a span of 2.1 m reinforced with both pre-stressing steel and GFRP were constructed and tested to failure using ACI 318-11 and ACI 440.1R-15. The concrete had strength of 31 MPa and the slabs were respectively reinforced with 5#4 bars and 3#5 bars. Each slab had 37.41 mm2 prestressing wire with a failure stress of 1722.5 MPa. The experimental flexural strength and deflection of slabs were compared with their respective sizes theoretical slabs. The theoretical slabs were either reinforced with pre-stressed steel or GFRP rebars, or a hybrid system. It was found that the hybrid system produces better results.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Nanni A, De Luca A, Zadeh J H. Introduction. In: Reinforced Concrete with FRP Bars. Florida: CRC Press-Taylor & Francis Group, 2014

    Chapter  Google Scholar 

  2. Guide for the Design and Construction of Structural Concrete Reinforced with Fiber-Reinforced Polymer (FRP) Bars. ACI 440.1R-15, 2015

  3. Nilson H A. Design of Prestressed Concrete. 2nd ed. Canada: John Wiley & Sons, Inc, 1987, 103

    Google Scholar 

  4. Singh B S. Design of RC Structures Reinforced with FRP Bars. In: Analysis and Design of FRP Reinforced Concrete Structures. New Delhi: McGraw-Hill, 2015, 67–78

    Google Scholar 

  5. Building Code Requirements for Structural Concrete. ACI 318-11, 2011

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Mohammed Faruqi.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Faruqi, M., Mata, O.I. & Aguiniga, F. Hybrid flexural components: Testing pre-stressed steel and GFRP bars together as reinforcement for flexural members. Front. Struct. Civ. Eng. 12, 352–360 (2018). https://doi.org/10.1007/s11709-017-0453-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11709-017-0453-3

Keywords

Navigation