Skip to main content

Advertisement

Log in

The Survivorship of the Uncemented Iso-Elastic Monoblock Acetabular Component at a Mean of 6-Year Follow-up

  • Original Article
  • Published:
HSS Journal ®

Abstract

Background

Aseptic loosening, caused by wear and osteolysis, is the most frequent reason for hip replacement revision in the UK. To prevent aseptic loosening, an acetabular component with vitamin E added to irradiated highly cross-linked polyethylene (HXLPE) was developed to reduce oxidative degradation.

Questions/Purposes

A prior study of the vitamin E–blended HXLPE acetabular component after 2 years of follow-up reported no adverse reactions or abnormal mechanical behavior. To further examine this hypothesis of reducing wear and osteolysis, we sought to evaluate outcomes after 6-year follow-up.

Methods

A cohort of 95 of the 112 initial patients (84.2%) completed the 6 years of follow-up after receiving a vitamin E–blended HXLPE acetabular component. Evaluation was performed in terms of clinical (visual analog scale [VAS] score, VAS score with weight-bearing, VAS score for satisfaction, and Harris Hip Score) and radiological (inclination, polar gap, radiolucencies, migration, and 2-D linear femoral head penetration rate) assessment.

Results

The mean VAS score for patient satisfaction was 8.75 and the mean Harris Hip Score was 91.8. There were two revisions because of deep infections and one because of a peri-prosthetic femoral fracture. Two acetabular components migrated initially; however, delayed acetabular stabilization occurred. Both patients had good clinical scores at 72 months. The mean femoral head penetration rate was 0.036 mm/year.

Conclusions

This prospective cohort study has shown no adverse reactions concerning the vitamin E additive, promising wear rates, no signs of osteolysis, a 100% survival rate for aseptic loosening, and an all-cause survivorship percentage of 97.4% at 6 years of follow-up.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Bracco P, Brunella V, Zanetti M, Luda M, Costa L. Stabilisation of ultra-high molecular weight polyethylene with vitamin E. Polymer Degradation and Stability. 2007;92(12):2155–2162.

    Article  CAS  Google Scholar 

  2. Bracco P, Bellare A, Bistolfi A, Affatato S. Ultra-high molecular weight polyethylene: influence of the chemical, physical and mechanical properties on the wear behavior. a review. Materials (Basel). 2017;10(7). E791.

    Article  Google Scholar 

  3. Brokelman RBG, Haverkamp D, van Loon C, Hol A, van Kampen A, Veth R. The validation of the visual analogue scale for patient satisfaction after total hip arthroplasty. Eur Orthop Traumatol. 2012;3:101–105.

    Article  Google Scholar 

  4. Callary S, Solomon L, Holubowycz O, Campbell D, Munn Z, Howie D. Wear of highly crosslinked polyethylene acetabular components. Acta Orthop. 2015;86:159–168.

    Article  Google Scholar 

  5. Dumbleton J, Manley M, Edidin A. A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplasty. 2002;17:649–661.

    Article  Google Scholar 

  6. Gasser B. Biomechanical principles and studies. In: Hip-joint surgery: the RM cup—long-term experience with an elastic monobloc acetabular implant. Horne G [ed]. Hamburg, Germany: Einhorn-Presse-Verlag. 2008.

    Google Scholar 

  7. Geerdink CH, Grimm B, Vencken W, Heyligers IC, Tonino AJ. The determination of linear and angular penetration of the femoral head into the acetabular component as an assessment of wear in total hip replacement: a comparison of four computer-assisted methods. J Bone Joint Surg Br. 2008;90:839–846.

    Article  CAS  Google Scholar 

  8. Halma J, Señaris J, Delfosse D, Lerf R, Oberbach T, van Gaalen S, de Gast A. Edge loading does not increase wear rates of ceramic-on-ceramic and metal-on-polyethylene articulations. J Biomed Mater Res Part B Appl Biomater. 2014;102:1627–1638.

    Article  Google Scholar 

  9. Halma J, Eshuis R, Vogely HC, van Gaalen S, de Gast A. An uncemented iso-elastic monoblock acetabular component: preliminary results. J Arthroplasty. 2015;30:615–621.

    Article  Google Scholar 

  10. Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969;51:737–755.

    Article  CAS  Google Scholar 

  11. Ihle M, Mai S, Pfluger D, Siebert W. The results of the titanium-coated RM acetabular component at 20 years: a long-term follow-up of an uncemented primary total hip replacement. J Bone Joint Surg Br. 2008;90:1284–1290.

    Article  CAS  Google Scholar 

  12. Jiang Y, Jia T, Wooley P, Yang S. Current research in the pathogenesis of aseptic implant loosening associated with particulate wear debris. Acta Orthop Belg. 2013;79:1–9.

    PubMed  Google Scholar 

  13. Kurtz S, Gawel H, Patel J. History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene. Clin Orthop Relat Res. 2011;469:2262–2277.

    Article  Google Scholar 

  14. Meneghini RM, Ford K, McCollough C, Hanssen A, Lewallen D. Bone remodeling around porous metal cementless acetabular components. J Arthroplasty. 2010;25:741–747.

    Article  Google Scholar 

  15. National Joint Registry for England, Wales, Northern Ireland, and the Isle of Man. 12th annual report. 2015. Available from http://www.njrcentre.org.uk/njrcentre/NJR-12th-Annual-Report

  16. Nebergall AK, Greene ME, Laursen MB, Nielsen PT, Malchau H, Troelsen A. Vitamin E diffused highly cross-linked polyethylene in total hip arthroplasty at five years: a randomised controlled trial using radiostereometric analysis. Bone Joint J. 2017;99-B:577–584.

    Article  CAS  Google Scholar 

  17. Pakvis D, Biemond L, van Hellemondt G, Spruit M. A cementless elastic monoblock socket in young patients: a ten to 18-year clinical and radiological follow-up. Int Orthop. 2011;35:1445–1451.

    Article  Google Scholar 

  18. Stihsen C, Pabinger C, Radl R, Rehak P, Windhager R. Migration of the Duraloc cup after 5 years. Int Orthop. 2008;32:791–794.

    Article  Google Scholar 

  19. Wyatt M, Weidner J, Pfluger D, Beck M. The RM Pressfit vitamys: 5-year Swiss experience of the first 100 cups. Hip Int. 2017;27(4):368–372.

    Article  Google Scholar 

  20. Yousif E, Haddad R. Photodegradation and photostabilization of polymers, especially polystyrene: review. Springerplus. 2013;2:398.

    Article  Google Scholar 

Download references

Funding

This study is funded by the Clinical Orthopedic Research Foundation, Diakonessenhuis Zeist.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to T. E. Snijders MD.

Ethics declarations

Conflict of Interest

T.E. Snijders, MD, J.J. Halma, MD, J.R.A. Massier, S.M. van Gaalen, MD, PhD, and A. de Gast, MD, PhD, declare that they have no conflict of interest.

Human/Animal Rights

All procedures followed were in accordance with the ethical standards of the responsible committee on human experimentation (institutional and national) and with the Helsinki Declaration of 1975, as revised in 2013.

Informed Consent

Informed consent was obtained from all patients for being included in this study.

Required Author Forms

Disclosure forms provided by the authors are available with the online version of this article.

Additional information

Level of Evidence: Level IV, Therapeutic Study

Electronic supplementary material

ESM 1

(PDF 1224 kb)

ESM 2

(PDF 1224 kb)

ESM 3

(PDF 1224 kb)

ESM 4

(PDF 1224 kb)

ESM 5

(PDF 1224 kb)

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Snijders, T.E., Halma, J.J., Massier, J.R.A. et al. The Survivorship of the Uncemented Iso-Elastic Monoblock Acetabular Component at a Mean of 6-Year Follow-up. HSS Jrnl 16, 15–22 (2020). https://doi.org/10.1007/s11420-018-09658-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11420-018-09658-8

Keywords

Navigation