Skip to main content
Log in

Comparison of Filtering Techniques in Ultrasound Color Flow Imaging

  • Published:
Biomedical Engineering Aims and scope

The article considers filtering techniques used to suppress clutter signals from moving tissues and to improve reliability of blood flow estimation. It compares polynomial and adaptive bases such as the result of empirical mode decomposition and singular vectors obtained through Karhunen−Loève transform. Filtering techniques are examined using a computer-simulated model, Doppler flow phantom and in vivo data. Filters are compared in terms of computational complexity, ability to retrieve flow profile without errors and through ROC curve analysis. Polynomial regression filters with tissue phase shift compensation were found to be the best fit for clutter suppression in terms of computational demands and accuracy of velocity estimation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Kulberg, N. S. and Leonov, D. V., “A program for the processing and analysis of ultrasound imaging signals in color Doppler blood flow mapping,” Certificate of state registration of computer programs No. 2018617330.

  2. Leonov, D. V., Kulberg, N. S., Gromov, A. I., Morozov, S. P., and Kim, S. Yu., “Causes of ultrasound Doppler twinkling artifact,” Acoustical Physics, 64, No. 1, 105-114 (2018).

    Article  Google Scholar 

  3. Scheipers, U., Perrey, C., Siebers, S., Hansen, C., and Ermert, H., “A tutorial on the use of ROC analysis for computer-aided diagnostic systems,” Ultrasonic Imaging, 27, No. 3, 181-198 (2005).

    Article  Google Scholar 

  4. Hindi, A., Peterson, C., and Barr, R. G., “Artifacts in diagnostic ultrasound,” Rep. Med. Imaging, 6, 29-48 (2013).

    Google Scholar 

  5. Zhang, Y., Gao, Y., Wang, L., Chen, J., and Shi, X., “The removal of wall components in Doppler ultrasound signals by using the empirical mode decomposition algorithm,” IEEE Trans. Biomed. Eng., 54, No. 9, 1631-1642 (2007).

    Article  Google Scholar 

  6. Wang, P. D., Shen, Y., and Feng, N. Z., “A novel clutter rejection scheme in color flow imaging,” Ultrasonics, No. 44, Supplement 1, e303-e305 (2006).

  7. Løvstakken, L., Signal Processing in Diagnostic Ultrasound: Algorithms for Real-Time Estimation and Visualization of Blood Flow Velocity, Doctoral Thesis, Norwegian University of Science and Technology (2007).

  8. Yoo, Y. M., Managuli, R., and Kim, Y., “Adaptive clutter filtering for ultrasound color flow imaging,” Ultrasound Med. Biol., 29, No. 9, 1311-1320 (2003).

    Article  Google Scholar 

  9. Kulberg, N. S., Gromov, A. I., Leonov, D. V., Osipov, L. V., Usanov, M. S., and Morozov, S. P., “Ultrasound Diagnostic Mode for Kidney Stone and Soft Tissue Calculi Detection,” Radiol. Prakt., 67, No. 1, 37-49 (2018).

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to D. V. Leonov.

Additional information

Translated from Meditsinskaya Tekhnika, Vol. 53, No. 2, Mar._Apr., 2019, pp. 15_18.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Leonov, D.V., Kulberg, N.S., Fin, V.A. et al. Comparison of Filtering Techniques in Ultrasound Color Flow Imaging. Biomed Eng 53, 97–101 (2019). https://doi.org/10.1007/s10527-019-09885-1

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10527-019-09885-1

Navigation