Simulation and Control of the H−Q Curves of the Sputnik Portable Ventricular Assist Device

  • Published:
Biomedical Engineering Aims and scope

A previously suggested approach to identification of pumping states of a rotary blood pump was verified using the head−flow curves of the Sputnik ventricular assist device. The curves were obtained using a mock circulatory loop under static conditions. The obtained results can be used for implementing a rotary blood pump control strategy intended to maintain the required flow rate and to identify the associated pumping states.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Petukhov D. S. and Telyshev D. V., “Simulation of blood flow dynamics changes through implantable axial flow pump,” Med. Tekh., No. 6, 44-47 (2014).

  2. Karantonis D. M., Lovell N. H., Ayre P. J. et al., “Identification and classification of physiologically significant pumping states in an implantable rotary blood pump,” Artif. Organs, 30, No. 9, 671-679 (2006).

    Article  Google Scholar 

  3. Selishchev S. and Telyshev D., “Ventricular assist device Sputnik: Description, technical features and characteristics,” Trends Biomat. Artif. Organs, 29, No. 3, 207-210 (2015).

    Google Scholar 

  4. Misgeld B. J., Ruschen D., Schwandtner S. et al., “Robust decentralised control of a hydrodynamic human circulatory system simulator,” Biomed. Sign. Process. Control, 20, 35-44 (2015).

    Article  Google Scholar 

  5. Pennings K. A., Martina J. R., Rodermans B. F. et al., “Pump flow estimation from pressure head and power uptake for the HeartAssist5, HeartMate II, and HeartWare VADs,” ASAIO J., 59, No. 4, 420-426 (2013).

    Article  Google Scholar 

  6. Yokoyama Y., Kawaguchi O., Kitao T. et al., “Prediction of the external work of the native heart from the dynamic H−Q curves of the rotary blood pumps during left heart bypass,” Artif. Organs, 34, 766-777 (2010).

    Article  Google Scholar 

  7. Noor M. R., Ho C. H., Parker K. H. et al., “Investigation of the characteristics of HeartWare HVAD and Thoratec HeartMate II under steady and pulsatile flow conditions,” Artif. Organs, 40, No. 6, 549-560 (2015).

    Article  Google Scholar 

  8. Stanfield J. R. and Selzman C. H., “In vitro pulsatility analysis of axial-flow and centrifugal-flow left ventricular assist devices,” J. Biomech. Eng., 135, No. 3, 1-6 (2013).

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to D. S. Petukhov.

Additional information

Translated from Meditsinskaya Tekhnika, Vol. 50, No. 6, Nov.-Dec., 2016, pp. 52-55.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Petukhov, D.S. Simulation and Control of the H−Q Curves of the Sputnik Portable Ventricular Assist Device. Biomed Eng 50, 429–432 (2017). https://doi.org/10.1007/s10527-017-9671-1

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10527-017-9671-1

Navigation