Skip to main content

Upper Limb Orthopaedic Trauma Implantology in a Nutshell

  • Reference work entry
  • First Online:
Handbook of Orthopaedic Trauma Implantology
  • 22 Accesses

Abstract

The past few decades have witnessed growing urbanisation leading to an increase in high energy injuries resulting in complex fracture patterns, especially of the upper limb.

Improvements in our understanding of the biomechanics of these injuries, coupled with technological advancements in imaging, metallurgy, computer-aided design and 3D printing, have led to development of a variety of specific implants to enable fixation of difficult fractures.

It is up to the operating surgeon to understand the fracture personality as well as biomechanical principles of the available implants and make a judicious choice based on these considerations.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 1,599.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 1,599.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Clinical practice guidelines (CPG) for the treatment of clavicle fractures, American Academy of Orthopaedic Surgeons (AAOS), January 2023.

    Google Scholar 

  2. Chalmers PN, Slikker W, Mall NA, Gupta AK, Rahman Z, Enriquez D, Nicholson GP. Reverse total shoulder arthroplasty for acute proximal humeral fracture: comparison to open reduction-internal fixation and hemiarthroplasty. J Shoulder Elb Surg. 2014;23:197–204.

    Article  Google Scholar 

  3. Voigt C, Geisler A, Hepp P, Schulz AP, Lill H. Are polyaxially locked screws advantageous in the plate osteosynthesis of proximal humeral fractures in the elderly? A prospective randomized clinical observational study. J Orthop Trauma. 2011;25:596–602.

    Article  PubMed  Google Scholar 

  4. Gardner MJ, Weil Y, Barker JU, Kelly BT, Helfet DL, Lorich DG. The importance of medial support in locked plating of proximal humerus fractures. J Orthop Trauma. 2007;21:185–91.

    Article  PubMed  Google Scholar 

  5. Chow RM, Begum F, Beaupre LA, Carey JP, Adeeb S, Bouliane MJ. Proximal humeral fracture fixation: locking plate construct ± intramedullary fibular allograft. J Shoulder Elb Surg. 2012;21:894–901.

    Article  Google Scholar 

  6. Hessmann MH, Korner J, Hofmann A, Sternstein W, Rommens PM. Angle-fixed plate fixation or double-plate osteosynthesis in fractures of the proximal humerus: a biomechanical study. Biomed Tech (Berl). 2008;53:130–7.

    Article  PubMed  Google Scholar 

  7. Dilisio MF, Nowinski RJ, Hatzidakis AM, Fehringer EV. Intramedullary nailing of the proximal humerus: evolution, technique, and results. J Shoulder Elb Surg. 2016;25:e130–8.

    Article  Google Scholar 

  8. Zhao JG, Wang J, Meng XH, Zeng XT, Kan SL. Surgical interventions to treat humerus shaft fractures: a network meta-analysis of randomized controlled trials. PLoS One. 2017 Mar;12(3):e0173634.

    Article  PubMed  PubMed Central  Google Scholar 

  9. Haglin JM, Kugelman DN, Egol KA, et al. Intra-articular distal humerus fractures: parallel versus orthogonal plating. HSS J. 2021 Apr;18(2) https://doi.org/10.1177/15563316211009810.

  10. Watson JJ, Bellringer S, Phadnis J. Coronal shear fractures of the distal humerus: current concepts and surgical techniques. Shoulder Elbow. 2020 Apr;12(2):124–35.

    Article  PubMed  Google Scholar 

  11. Swensen SJ, Tyagi V, Uquillas C, Shakked RJ, Yoon RS, Liporace FA. Maximizing outcomes in the treatment of radial head fractures. J Orthop Traumatol. 2019 Mar 23;20(1):15.

    Article  PubMed  PubMed Central  Google Scholar 

  12. Lor KKH, Toon DH, Wee ATH. Buttress plate fixation of coronoid process fractures via a medial approach. Chin J Traumatol. 2019 Oct;22(5):255–60.

    Article  PubMed  PubMed Central  Google Scholar 

  13. Leung F, Chow SP. Locking compression plate in the treatment of forearm fractures: a prospective study. J Orthop Surg. 2006;14(3):291–4.

    Article  CAS  Google Scholar 

  14. Slutsky DJ, Osterman AL. Fractures and injuries of the distal radius and carpus-the cutting edge. Philadelphia: Saunders/Elsevier; 2009.

    Google Scholar 

  15. Dyrna FGE, Avery DM, et al. Metacarpal shaft fixation: a biomechanical comparison of dorsal plating, lag screws, and headless compression screws. BMC Musculoskeletal Disord. 2021;22:335.

    Article  Google Scholar 

  16. Lögters TT, Lee HH, Gehrmann S, Windolf J, Kaufmann RA. Proximal phalanx fracture management. Hand (N Y). 2018 July;13(4):376–83.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Section Editor information

Rights and permissions

Reprints and permissions

Copyright information

© 2023 Springer Nature Singapore Pte Ltd.

About this entry

Check for updates. Verify currency and authenticity via CrossMark

Cite this entry

Bharadwaj, R.G. (2023). Upper Limb Orthopaedic Trauma Implantology in a Nutshell. In: Banerjee, A., Biberthaler, P., Shanmugasundaram, S. (eds) Handbook of Orthopaedic Trauma Implantology. Springer, Singapore. https://doi.org/10.1007/978-981-19-7540-0_77

Download citation

  • DOI: https://doi.org/10.1007/978-981-19-7540-0_77

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-19-7539-4

  • Online ISBN: 978-981-19-7540-0

  • eBook Packages: MedicineReference Module Medicine

Publish with us

Policies and ethics