Abstract
High-resolution protein separation techniques critically depend on the availability of column packings of small average particle size. This gives a minimum of peak broadening on the column owing to the direct relationship between the theoretical plate height parameter, H, and particle size (lowest values of H give the highest resolution). High-performance liquid chromatography (HPLC) procedures exploit column packings with average diameters of as small as 5–40 μm. However, these are used in high-pressure systems (up to 400 bar) often with organic solvents and are generally limited to rather low sample loadings (1). To provide a more biocompatible high-resolution separation of biopolymers, including (although not exclusive to) proteins, Pharmacia (Uppsala, Sweden; now known as, Amersham Biosciences) developed fast protein liquid chromatography (FPLC) in 1982 (2). More recently, Regnier and his colleagues developed “perfusive” packings that contain large through-pores (3). These allow high-resolution chromatography with ion-exchange groups similar to those of Amersham Biosciences columns but at much faster flow rates, giving remarkably short separation times (e.g., 5–7 min). Perfusion chromatography columns are also compatible with the FPLC system.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Boyer, R. F. (1993) Separation and purification of biomolecules by chromatography, in Modern Experimental Biochemistry, Benjamin-Cummings, Redwood City, CA, pp. 90–102.
Richey, J. (1982) FPLC: a comprehensive separation technique for biopolymers. Am. Lab. 14, 104–129.
Regnier, F. E. (1991) Perfusion chromatography. Nature 350, 634–635.
Fagerstam, L. G., Lizana, J., Axio-Fredriksson, U.-B., and Wahlstrom, L. (1983) Fast chromatofocusing of human serum proteins with special reference to α1-antitrypsin and Gc-globulin. J. Chromatogr. 266, 523–532.
Fagerstam, L. G. and Pettersson, G. L. (1979) The cellulytic complex of Trichoderma reesei QM9414. An immunological approach. FEBS Lett. 98, 363–367.
Jeppson, J.-O., Kallman, I., Lindgren, G., and Fagerstam, L. (1984) A new hemoglobin mutant characterised by reverse phase chromatography. J. Chromatogr. 297, 31–36.
Fitzpatrick, P. J. and Sheehan, D. (1993) Separation of multiple forms of glutathione S-transferase from the blue mussel, Mytilus edulis. Xenobiotica 23, 851–862.
Havarstein, L. S., Aasjord, P. M., Ness, S., and Endresen, G. (1988) Purification and partial characterisation of an IgM-like serum immunoglobulin from Atlantic salmon (Salmo salar). Dev. Comp. Immunol. 12, 773–785.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2004 Humana Press Inc., Totowa, NJ
About this protocol
Cite this protocol
Sheehan, D., O’Sullivan, S. (2004). Fast Protein Liquid Chromatography. In: Cutler, P. (eds) Protein Purification Protocols. Methods in Molecular Biology, vol 244. Humana Press. https://doi.org/10.1385/1-59259-655-X:253
Download citation
DOI: https://doi.org/10.1385/1-59259-655-X:253
Publisher Name: Humana Press
Print ISBN: 978-1-58829-067-0
Online ISBN: 978-1-59259-655-3
eBook Packages: Springer Protocols