Stereotactic implantation of deep brain stimulation electrodes: a review of technical systems, methods and emerging tools Simone HemmKarin Wårdell Review Article 02 June 2010 Pages: 611 - 624
Parameter estimation of the copernicus decompression model with venous gas emboli in human divers Christian R. GutvikRichard G. DunfordAlf O. Brubakk Original Article 23 April 2010 Pages: 625 - 636
The influence of skeletal muscle anisotropy on electroporation: in vivo study and numerical modeling Selma ČorovićAnže ŽupaničDamijan Miklavčič Original Article Open access 28 April 2010 Pages: 637 - 648
Reverse engineering the kidney: modelling calcium oxalate monohydrate crystallization in the nephron A. BorissovaG. E. GoltzT. A. Wilkins Original Article 28 April 2010 Pages: 649 - 659
A simulation technique for computation of the dosimetric effects of setup, organ motion and delineation uncertainties in radiotherapy Bongile MzendaMir Hosseini-AshrafiDavid J. Brown Original Article 23 April 2010 Pages: 661 - 669
Fractal dimension values of cerebral and cerebellar activity in rats loaded with aluminium Goran KekovicMilka CulicSlobodan Sekulic Original Article 28 April 2010 Pages: 671 - 679
Influence of graft quality and marginal bone loss on implants placed in maxillary grafted sinus: a finite element study Samroeng InglamSiriwan SuebnukarnKriskrai Sitthiseripratip Original Article 29 April 2010 Pages: 681 - 689
Wear patterns of, and wear volume formulae for, cylindrically elongated acetabular cup liners James Shih-Shyn WuShu-Ling HsuJian-Horng Chen Original Article 28 April 2010 Pages: 691 - 701
Analysis of biomechanical changes after removal of instrumentation in lumbar arthrodesis by finite element analysis Ho-Joong KimHeoung-Jae ChunHwan-Mo Lee Original Article 04 May 2010 Pages: 703 - 709
Does femoral strain distribution coincide with the occurrence of cervical versus trochanteric hip fractures? An experimental finite element study Janne E. M. KoivumäkiJérôme ThevenotTimo Jämsä Original Article 21 May 2010 Pages: 711 - 717
Editorial comment on Malkin and Keane (2010) Herbert F. VoigtShankar M. Krishnan Editorial 27 May 2010 Pages: 719 - 720
Evidence-based approach to the maintenance of laboratory and medical equipment in resource-poor settings Robert MalkinAllison Keane Editorial 21 May 2010 Pages: 721 - 726
Scintigraphy vs. mechanical magnetogastrography: gastric emptying analysis J. M. De la Roca-ChiapasT. Córdova-FragaM. Vargas-Luna Letter 21 May 2010 Pages: 727 - 729
An electrooptical muscle contraction sensor Alessio ChianuraMario E. Giardini Letter 21 May 2010 Pages: 731 - 734