Thermal method for continuous measurement of cerebral perfusion D. WeiG. M. SaidelS. C. Jones Physiological Measurement Pages: 481 - 488
Bilateral asymmetry of respiratory acoustic transmission G. R. WodickaP. D. DeFrainS. S. Kraman Physiological Measurement Pages: 489 - 494
Non-invasive conductivity technique to detect changes in haematocrit:in vitro validation C. G. OlthofP. M. KouwP. M. J. M. de Vries Physiological Measurement Pages: 495 - 500
Comparison of two methods for correcting ocular artefacts in EEGs M. M. C. van den Berg-LenssenJ. A. M. van GisbergenB. W. Jervis Physiological Measurement Pages: 501 - 511
Intracranial pressure dynamics in clinical practice: online PC-based ICP monitoring system M. A. GonzalezM. A. QuilesC. H. Salvador Physiological Measurement Pages: 512 - 520
Analogue and digital instruments for non-invasive estimation of muscle fibre conduction velocity A. FioritoS. RaoR. Merletti Physiological Measurement Pages: 521 - 529
Finite-element method in electrical impedance tomography E. J. WooP. HuaW. J. Tompkins Medical Physics and Imaging Pages: 530 - 536
Unsupervised clustering of evoked potentials by waveform A. B. GevaH. Pratt Computing Pages: 543 - 550
Radio-immunotherapy dosimetry with special emphasis on SPECT quantification and extracorporeal immuno-adsorption S. -E. StrandM. LjungbergM. Garkavij Review Pages: 551 - 561
New technique for assessment of velopharyngeal function H. R. MirlohiS. W. KellyM. C. G. Manley Communication Pages: 562 - 566
Digital demodulation in bio-impedance measurement N. ChauveauB. RigaudJ. P. Morucci Communication Pages: 566 - 571
Classification of non-averaged EEG data by learning vector quantisation and the influence of signal preprocessing D. FlotzingerG. PfurtschellerW. Mohl Communication Pages: 571 - 576
Microfabricated printed circuit for measuring oxygenin vitro A. E. BrewsterP. WallR. Pickard Communication Pages: 576 - 579
Performance characteristics of a pulsed plasma cathode X-ray source operated without diode closure S. KashiwabaraK. WatanabeR. Fujimoto Technical Note Pages: 580 - 584
Computerised emiconductor probe-based system forin vivo dosimetry of patients undergoing high-energy radiotherapy F. Sánchez-DobladoR. ArránsL. Errazquin Technical Note Pages: 588 - 592
System based on a digital signal processor for real-time cross-correlation of neural signals L. FioreM. PirchioC. Fiorino Technical Note Pages: 593 - 596
Standard algorithm of blood-pressure measurement by the oscillometric method Andrzej SapińskiKen-ichi YamakoshiShinobu Tanaka Letter Pages: 599 - 600