Medical and Biological Engineering and Computing

, Volume 32, Issue 5, pp 588–592 | Cite as

Computerised emiconductor probe-based system forin vivo dosimetry of patients undergoing high-energy radiotherapy

  • F. Sánchez-Doblado
  • R. Arráns
  • J. A. Terrón
  • B. Sánchez-Nieto
  • L. Errazquin
Technical Note

Keywords

Computerised system Data acquisition In vivo dosimetry Total body irradiation 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Analog Devices: INTEGRATED CIRCUITS. (1984) Databook, vol. 1Google Scholar
  2. Arráns, R., Bodineau, C., Sánchez-Doblado, F., andErrazquin, L. (1990): ‘Optimization in TBI dosimetry.’ Proc. European Mevatron Users Conference, Berlin, pp. 165–174Google Scholar
  3. Bodineau, C., Mateos, J. C., Arráns, R., Ureña, J., andSánchez-Doblado, F. (1989): ‘Dispositivo de emulación para adquisición de señales dosimtricas,’Libro de Trabajos del VII Congreso Nacional de Física Médica,1, Oviedo, pp. 93–98Google Scholar
  4. Bodineau, C., Ureña, J., Arráns, R., Errazquin L., andSánchez-Doblado, F. (1989): ‘Diseño e implementación de una interfase electrómetro microordenador para dosimetría de radiaciones ionizantes’.Libro de Trabajos del VII Congreso Nacional de Física Médica,1, Oviedo, pp. 99–106Google Scholar
  5. Broerse, J. J., andVarekamp, A. E. (1987): ‘Total body irradiation for treatment of hematological diseases,’Radiot. Oncol.,9, pp. 87–90Google Scholar
  6. Gómez-Vela, D. (1983) ‘Estudio de la respuesta inicial de un conjunto de diodos semiconductores frente a un haz de Co-60’.IV Reunión Nacional de Fisica Médica,1, pp. 412–428Google Scholar
  7. Gonzalez, V., Herrador, M., Errazquin, L., Sánchez-Doblado, F.,et al. (1990): ‘Clinical results of TBI for bone-marrow transplantation at Sevilla,’Radiot. Oncol., Suppl.1, pp. 110–113CrossRefGoogle Scholar
  8. Grusell, E., andRikner, G. (1988): ‘Evaluation of temperature effects in a p-type silicon detectors,’Phys. Med. Biol.,31, 5, pp. 527–534CrossRefGoogle Scholar
  9. Nilsson, B. (1988): ‘Characteristics of silicon diode patient dosimeters in external radiation therapy,’Radiot. Oncol.,11, pp. 279–288CrossRefGoogle Scholar
  10. Novack, D. H., andRiley, J. P. (1987): ‘Total body irradiation’,Front. Radiat. Ther. Onc.,21, pp. 68–83Google Scholar
  11. Peatman, J. (Ed.) (1977): ‘Microcomputer-based design’ (McGraw-Hill, New York).Google Scholar
  12. Quast, U. (1982): ‘Summary of the discussion on in vivo dosimetry,’J. Eur. Radiother.,3, pp. 259–261Google Scholar
  13. Rikner, G., andGrusell, E. (1983): ‘Effects of radiation damage on p-type silicon detectors,’Phys. Med. Biol.,28, pp. 1261–1270CrossRefGoogle Scholar
  14. Rikner, G. (1985): ‘Characteristics of a selectively shielded p-Si detector in Co-60, 8 and 16 MV Roentgen radiation,’Acta Radiol. Oncol.,24, pp. 205–208Google Scholar
  15. Rizzoti, A. (1985): ‘Dose evaluation to patients irradiated by60Co beams, by means of direct measurement on the incident and on the exit surfaces,’Radiot. Oncol.,3, pp. 279–283Google Scholar
  16. Sánchez-Doblado, F., Arráns, R., Ureña, J., andErrazquin, L. (1990): ‘Data acquisition system for in vivo dosimetry.’ Proc. Tenth Int. Conf. on the use of Computers in Radiation Therapy, Lucknow, India, pp. 159–163Google Scholar
  17. Sánchez-Doblado, F. Quast, U., Arráns, R., Errazquin, L., Sánchez-Nieto, B., andTerrón, J. A. (1993): ‘Recommendations for registration of physical parameters of total body irradiation prior to bone marrow transplantation.’ Report European Bone Marrow TransplantationGoogle Scholar
  18. Sociedad Española De Física Médica (1984): ‘Procedimientos recomendados para la dosimetría de fotones y electrones de energías comprendidas entre 1 MV y 50 MV en radioterapia de haces externos.’ SEFM 1Google Scholar
  19. Sociedad Española De Física Médica (1987): ‘Suplemento al documento SEFM no 1-1984: Procedimentos recomendados para la dosimetría de fotones y electrones de energías comprendidas entre 1 MV y 50 MV en radioterapia de haces externos.’ SEFM 2Google Scholar
  20. Terrón, J. A., Rodríguez, L., Sánchez-Doblado, F., Arráns, R., Sánchez-Nieto, B., andErrazquin, L. (1991): ‘Diseño e Implementación de un Sistema Computarizado para el Cálculo de la Dosis Absoluta de Referencia.’ Libro de Actas del VIII Congreso de Física Médica. Sevilla, pp. 305–309Google Scholar
  21. Therados (1983): User manualGoogle Scholar
  22. Thomas, E. D., Storb, R., andClift, R. A. (1975): ‘Bone marrow transplantation,’N. Engl. J. Med.,292, pp. 832–843CrossRefGoogle Scholar
  23. Van Dyck, J., Galvin, J. M., Glasgow, G. P., andPodgorsak, E. B. (1986): ‘The physical aspects of total and half body irradiation.’ AAPM Report 17Google Scholar
  24. Van Dyck, J. (1987): ‘Dosimetry for total body irradiation,’Radiat. Oncol.,9, pp. 107–118Google Scholar

Copyright information

© IFMBE 1994

Authors and Affiliations

  • F. Sánchez-Doblado
    • 1
    • 2
  • R. Arráns
    • 2
  • J. A. Terrón
    • 1
  • B. Sánchez-Nieto
    • 1
  • L. Errazquin
    • 2
  1. 1.Depto. Fisiologia Med. y BIOFÍSICA, Fac. MedicinaUniversidad de SevillaSpain
  2. 2.Serv. Oncología Radiot. Hosp. V. Macarena. Avda. Dr. Fedriani, s/nSevillaSpain

Personalised recommendations