Abstract
Background
There are few reports on the detailed biomechanics of the deltoid ligament, and no studies have measured the biomechanics of each ligamentous band because of the difficulty in inserting sensors into the narrow ligaments. This study aimed to measure the strain pattern of the deltoid ligament bands directly using a Miniaturization Ligament Performance Probe (MLPP) system.
Methods
The MLPP was sutured into the ligamentous bands of the deltoid ligament in 6 fresh-frozen lower extremity cadaveric specimens. The strain was measured using a round metal disk (clock) fixed on the plantar aspect of the foot. The ankle was manually moved from 15° dorsiflexion to 30° plantar flexion, and a 1.2-N-m force was applied to the ankle and subtalar joint complex. Then the clock was rotated every 30° to measure the strain of each ligamentous band at each endpoint.
Results
The tibionavicular ligament (TNL) began to tense at 10° plantar flexion, and the tension becomes stronger as the angle increased; the TNL worked most effectively in plantar flex-abduction. The tibiospring ligament (TSL) began to tense gradually at 15° plantar flexion, and the tension became stronger as the angle increased. The TSL worked most effectively in abduction. The tibiocalcaneal ligament (TCL) began to tense gradually at 0° dorsiflexion, and the tension became stronger as the angle increased. The TCL worked most effectively in pronation (dorsiflexion-abduction). The superficial posterior tibiotalar ligament (SPTTL) began to tense gradually at 0° dorsiflexion, and the tension became stronger as the angle increased, with the SPTTL working most effectively in dorsiflexion.
Conclusion
Our results show the biomechanical function of the superficial deltoid ligament and may contribute to determining which ligament is damaged during assessment in the clinical setting.
Similar content being viewed by others
Background
The deltoid ligament has both superficial and deep layers consisting of up to six ligamentous bands [1]. The superficial layer of the deltoid ligament is composed of four ligamentous bands, including the tibionavicular (TNL), tibiospring (TSL), tibiocalcaneal (TCL), and superficial posterior tibiotalar (SPTTL) ligaments. Two ligamentous bands comprise the deep layer of the deltoid ligament: the deep anterior and posterior tibiotalar ligaments. Generally, the deltoid ligament is known to work cooperatively and is primarily responsible for 1) stabilizing the medial side of the ankle to limit anterior, posterior, and lateral translation of the talus and 2) restraining talar abduction at the talocrural joint [2, 3]. Specifically, the superficial deltoid resists eversion of the hindfoot, and the deep deltoid is the primary restraint to external rotation of the talus [4,5,6,7].
There are few reports in terms of detailed biomechanics of the deltoid ligament [8,9,10,11,12], and no studies have directly measured the biomechanics of each ligamentous band because of the difficulty in inserting sensors into the narrow ligaments.
Biomechanical data regarding each ligamentous band would contribute to precisely assessing which ligament is damaged in the clinical setting, leading to the design and performance of repair and reconstruction procedures before surgery. Thus, we used a Miniaturization Ligament Performance Probe (MLPP) system that can be inserted into small ligaments and allows for the precise measurement of the strain patterns of the deltoid ligament during ankle motion.
Methods
MLPP system
The MLPP system is composed of a strain gauge (force probe), an amplifier unit, a display unit, and a logger (Fig. 1). This system is capable of detecting small changes in resistance on the force probe. These changes in resistance are then enlarged by the bridge of an amplifier unit and transferred to the input of the display unit. After analogue-to-digital conversion by the display unit, the amount of strain is displayed. This strain measurement is converted to analogue, and its voltage is finally recorded in the logger.
The force probe (Showa unilateral strain gauge; Showa Measuring Instruments Inc., Tokyo, Japan) is rectangular (width, 1.4 mm; height, 1.4 mm; length, 8 mm) and has a tubular structure with slits entering vertically on one side of its surface (Fig. 2a). When strain is applied to the force probe, the internal strain gauge is distorted, allowing the magnitude of strain to be measured. When the force probe is inserted into the tissue, it may rotate as forces are applied, causing the output to be reduced or inverted. To suppress this rotational influence, a tube was attached to the force probe, and both ends were sutured to the tissue to be measured (Fig. 2b).
A performance cube was used to measure the position of the ankle (Fig. 3). The cube is composed of an MPU-9250 motion-processing sensor with a nine-axis sensor, an ESP32 microcontroller, and a logger. The MPU-9250 and ESP32 are loaded in the performance cube. The MPU-9250 is a sensor that acquires position information and can acquire values of motion in nine axes in total, each with angular acceleration, and geomagnetism. The MPU-9250 is equipped with hardware called a digital motion processor, which automatically performs measurements at the time of initialization of the sensor and calculates posture. The ESP32 is a microcontroller that calculates data obtained from the MPU-9250 and transmits data to the logger via a WiFi module. This performance cube is synchronized with the MLPP system.
Cadaveric tests using the MLPP system
Six fresh-frozen through-the-knee lower extremity cadaveric specimens were used for this study (three right and three left). Three specimens were from men, and three were from women. The median age was 64 years (range 46–82 years). These specimens were free of ankle or hind foot deformities, did not undergo surgery or dissection, and did not have any history of trauma or other pathology that may alter the anatomy.
All cadaveric studies were performed at the University of Barcelona in Catalonia, Spain. All methods in this study were reviewed and approved by the Institutional Review Board of the University of Barcelona. Consent for the storage and use of the bodies for research purposes was given by all body donors before death or by their next of kin.
Experiments on strain patterns of the superficial deltoid ligament
The following procedures were performed in all specimens by a single experienced foot and ankle surgeon. An incision was made in the medial ankle, and the superficial layer of the deltoid ligament was exposed. Lines were drawn on the ligaments to trace each ligament from its origin to insertion on the bone (Fig. 4a). Ligaments were not isolated in order to investigate them as one unit. A force probe was placed in the mid-substance of each ligamentous band of the TNL, TSL, TCL, and SPTTL such that the slit of the force probe was aligned with the long axis of the ligament fibers (Fig. 4b). After introducing the force probe into the ligament, the force probe tube was sutured to the ligament fibers with 3–0 nylon thread to prevent the rotation of the force probe.
An Ilizarov ring-shaped external fixator was placed on the lower leg, and the lower limb was fixed vertically to the measurement desk using a vise to allow for the localization of the distal upper and proximal lower portions of the specimens. A round metal disk (clock, diameter 150 mm) with a 6-mm diameter hole every 30°, was affixed to an acrylic plate (width, 120 mm; length, 280 mm; thickness, 10 mm). The plate was fixed on the plantar aspect of the foot with a screw (diameter 6 mm) inserted into the calcaneus and a rod (diameter 8 mm) inserted between the second and third metatarsals (Fig. 3). This plate had a 25-cm arm where a 0.5-kg weight could be added at the end, applying a 1.2-N m force to the ankle and subtalar joint complex (0.5 kg × 0.25 m × 9.81 = 1.23 N m). This design resulted from a pilot study that used specimens to determine appropriate loading levels in order to achieve maximum range of motion where the plate would return to its original shape and length.
This arm was rotated every 30° on the clock to allow for measurement of the strain on each ligamentous band at various ankle positions. The ankle positions were defined as dorsiflexion with the arm at the 12 o’clock position, plantar flexion at the 6 o’clock position, inversion at the 3 o’clock position, and eversion at 9 o’clock position; in addition, 1 and 2 o’clock were defined as dorsiflexion-adduction, 4 and 5 o’clock were defined as supination (plantar flexion adduction), 7 and 8 o’clock were defined as plantarflexion- abduction, and 10 and 11 o’clock were defined as pronation (dorsiflexion-abduction).
After the investigation of strain in the designated ankle positions, the strain values of each ligament were also measured in axial motion of the ankle from maximal dorsiflexion to plantar flexion.
The angles of axial, sagittal, and horizontal motions were measured by an electronic goniometer (MPU-9250; TDK InvenSense, San Jose, CA, USA) synchronized to the MLPP system.
Data analysis
The relationship between the foot positions and the tensile forces of each ligamentous band was analyzed. The tensile force data from the force probe were obtained by synchronizing the arm of the clock, which rotated every 30°, with the movement of the ankle from 15° dorsiflexion to 30° plantar flexion 10 times manually, and the strain of each ligamentous band during ankle motion was measured. Individual strain data were aligned to the value at neutral position (0) and to the maximum value (100). The average value at each position was connected by a line, and the ligament tension pattern was compared among the specimens.
Results
Tibionavicular ligament
The TNL was under the most strain in plantarflexion-abduction (Fig. 5a). The TNL began to tense gradually at 10° plantarflexion. The strain became stronger as the plantarflexion angle increased to a maximum strain of 100 at 30° plantarflexion (Fig. 5b).
Tibiospring ligament
The TSL was under the most strain in eversion (Fig. 6a). The TSL began to tense gradually at 15° plantarflexion. The strain became stronger as the plantarflexion angle increased to a maximum strain of 100 at 30° plantarflexion (Fig. 6b).
Tibiocalcaneal ligament
The TCL was under the most strain in pronation (Fig. 7a). The TCL began to tense gradually at 0° dorsiflexion. The strain became stronger as the dorsiflexion angle increased to a maximum strain of 100 at 15° dorsiflexion (Fig. 7b).
Superficial posterior tibiotalar ligament
The SPTTL was under the most strain in dorsiflexion (Fig. 8a). The SPTTL began to tense gradually at 0° dorsiflexion. The strain became stronger as the dorsiflexion angle increased to a maximum strain of 100 at 15° dorsiflexion (Fig. 8b).
Discussion
In this study, we gained a comprehensive understanding of the contribution of each ligamentous band in the deltoid ligament to overall ankle stability at various ankle positions.
Previous studies have evaluated biomechanics 1) by using a laboratory reference axis system to obtain a three-plane description of movements [13], 2) after sectioning each ligamentous band [5], 3) by using reluctance transducers to measure change in the deltoid ligament length [9], 4) by using computational models [10], and 5) by using a marker-based motion analysis [11]. This is the first study in which each ligamentous band of the deltoid was investigated without transection; thus, we precisely assessed how each ligament works.
We found that the TNL, TSL, TCL, and SPTTL work most effectively in plantar flexion-abduction, abduction, pronation (dorsiflexion-abduction), and dorsiflexion, respectively. In the clinical setting, by examining the range of pain, the physician could evaluate which ligament is damaged, and then the results would make it possible to determine whether surgery is necessary in accordance with the person’s life and exercise.
Repair of the deltoid ligament is now controversial. In addition, clear indications for operative repair have not yet been well established. Some studies have shown that repair of the ruptured ligament is beneficial and can produce satisfactory results [8, 12, 14, 15]. By contrast, other studies showed repair of the deltoid ligament to be unnecessary [6, 16,17,18,19]. There may be some advantages of adding deltoid ligament repair for patients with high fibular fractures or in patients with concomitant syndesmotic injury and fixation [20], but previous studies did not evaluate each ligamentous band by physical examination before surgery. In this study, we clarified the biomechanics of each ligamentous band of the deltoid ligament. This will allow for detailed preoperative assessment of ligament damage and adaptation of operative techniques and procedures, possibly leading to established indicators for operation.
Limitations
The disadvantage of MLPP is that it measures the strain value of the ligament instead of tensile force. In the elastic range where the deltoid ligament can return to its original shape and length, force and strain showed a linear proportional relationship. Therefore, it is theoretically possible to convert the measured strain value to Newton force if Young’s modulus is obtained by calibration. However, it is difficult to accurately determine Young’s modulus because the water content of the tissue decreases with time and the elasticity of the ligaments changes. The acceptable variation in the results of this study might be influenced by temporal changes in the elasticity of the ligaments. In addition, the preservation process of fresh-frozen cadavers influenced elasticity.
Conclusions
We demonstrated biomechanical properties of each ligamentous band of the superficial layer of the deltoid ligament. These findings provide a better understanding of the biomechanical function of the deltoid ligament, which could help in informing repair and reconstruction procedures.
Availability of data and materials
The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.
Abbreviations
- MLPP:
-
Miniaturization Ligament Performance Probe
- SPTTL:
-
Superficial posterior tibiotalar ligament
- TCL:
-
Tibiocalcaneal ligament
- TNL:
-
Tibionavicular ligament
- TSL:
-
Tibiospring ligament
References
Pankovich AM, Shivaram MS. Anatomical basis of variability in injuries of the medial malleolus and the deltoid ligament. I Anatomical Studies Acta Orthop Scand. 1979;50:217–23.
Cromeens BP, Kirchhoff CA, Patterson RM, Motley T, Stewart D, Fisher C, et al. An attachment-based description of the medial collateral and spring ligament complexes. Foot Ankle Int. 2015;36:710.
Brodell JD Jr, MacDonald A, Perkins JA, Deland JT, Oh I. Reconstruction of the deltoid-spring ligament: tibiocalcaneonavicular ligament complex. Tech Foot Ankle Surg. 2016;15:39–46.
Earll M, Wayne J, Brodrick C, Vokshoor A, Adelaar R. Contribution of the deltoid ligament to ankle joint contact characteristics: a cadaver study. Foot Ankle Int. 1996;17:317–24.
Harper MC. An anatomic study of the short oblique fracture of the distal fibula and ankle stability. Foot Ankle. 1983;4:23–9.
Harper MC. Deltoid ligament: an anatomical evaluation of function. Foot Ankle. 1987;8:19–22.
Harper MC. The deltoid ligament. An evaluation of need for surgical repair. Clin Orthop Relat Res. 1988;226:156–68.
Hsu AR, Lareau CR, Anderson RB. Repair of acute superficial deltoid complex avulsion during ankle fracture fixation in National Football League players. Foot Ankle Int. 2015;36:1272–8.
Tochigi Y, Rudert MJ, Amendola A, Brown TD, Saltzman CL. Tensile engagement of the peri-ankle ligaments in stance phase. Foot Ankle Int. 2005;26:1067–73.
Wei F, Hunley SC, Powell JW, Haut RC. Development and validation of a computational model to study the effect of foot constraint on ankle injury due to external rotation. Ann Biomed Eng. 2011;39:756–65.
Wei F, Braman JE, Weaver BT, Haut RC. Determination of dynamic ankle ligament strains from a computational model driven by motion analysis based kinematic data. J Biomech. 2011;44:2636–41.
Yu GR, Zhang MZ, Aiyer A, Tang X, Xie M, Zeng LR, et al. Repair of the acute deltoid ligament complex rupture associated with ankle fractures: a multicenter clinical study. J Foot Ankle Surg. 2015;54:198–202.
Kjaersgaard-Andersen P, Wethelund JO, Helmig P, Søballe K. Stabilizing effect of the tibiocalcaneal fascicle of the deltoid ligament on hindfoot joint movements: an experimental study. Foot Ankle. 1989;10:30–5.
Johnson D, Hill J. Fracture-dislocation of the ankle with rupture of the deltoid ligament. Injury. 1988;19:59–61.
Little MM, Berkes MB, Schottel PC, Garner MR, Lazaro LE, Birnbaum JF, et al. Anatomic fixation of supination external rotation type IV equivalent ankle fractures. J Orthop Trauma. 2015;29:250–5.
Baird RA, Jackson ST. Fractures of the distal part of the fibula with associated disruption of the deltoid ligament. Treatment without repair of the deltoid ligament. J Bone Joint Surg Am. 1987;69:1346–52.
De Souza L, Gustilo RB, Meyer TJ. Results of operative treatment of displaced external rotation-abduction fractures of the ankle. JBJS. 1985;67:1066.
Tourne Y, Charbel A, Picard F, Montbarbon E, Saragaglia D. Surgical treatment of bi-and trimalleolar ankle fractures: should the medial collateral ligament be sutured or not? J Foot Ankle Surg. 1999;38:24–9.
Zeegers AV, van der Werken C. Rupture of the deltoid ligament in ankle fractures: should it be repaired? Injury. 1989;20:39–41.
Dabash S, Elabd A, Potter E, Fernandez I, Gerzina C, Thabet AM, et al. Adding deltoid ligament repair in ankle fracture treatment: is it necessary? Syst Rev. 2018;18:30223–6.
Acknowledgments
Not applicable.
Funding
All authors have no financial relationships relevant to this article to disclose.
Author information
Authors and Affiliations
Consortia
Contributions
MT, SO, XO, and MG designed the study; MT, SO, XO, TY, YT, MK, DL, KM, MK, and MG performed the research; and RI wrote the first draft. All authors read and approved the final manuscript.
Corresponding author
Ethics declarations
Ethics approval and consent to participate
This cadaveric study was approved by the Institutional Review Board of the University of Barcelona and conducted in accordance with the bylaws of the Bioethics Committee of the “Unitat d’ Anatomia i Embriologia humana” of the Faculty of Medicine, University of Barcelona, Spain (Campus Clinic). Consent for the storage and use of the bodies for research purposes was given by all body donors before death or by their next of kin.
Consent for publication
Not applicable.
Competing interests
The authors declare that they have no competing interests.
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
About this article
Cite this article
Takao, M., Ozeki, S., Oliva, X.M. et al. Strain pattern of each ligamentous band of the superficial deltoid ligament: a cadaver study. BMC Musculoskelet Disord 21, 289 (2020). https://doi.org/10.1186/s12891-020-03296-0
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s12891-020-03296-0