Skip to main content
Log in

Potential Application of Entangled Porous Titanium Alloy Metal Rubber in Artificial Lumbar Disc Prostheses

  • Published:
Journal of Bionic Engineering Aims and scope Submit manuscript

Abstract

Entangled Porous Titanium Alloy Metal Rubber (EPTA-MR) was used as a nucleus pulposus material in the design of non-fusion intervertebral disc prosthesis for the first time. A novel artificial lumbar intervertebral disc prosthesis was designed by reconstructing the lumbar model with reverse engineering technology, and the biomechanical behavior of the prosthesis was simulated under varied working conditions. The nucleus pulposus size was determined by the actual size of human prosthesis. EPTA-MR samples with different densities were prepared by medical titanium alloy wire experimental studies were conducted on static stiffness, damping energy consumption, and fatigue life. The results indicated that the static stiffness of EPTA-MR could reach approximately 1500 N·mm−1, and its loss factor remained higher than 0.2, and the variation range was relatively small, with excellent vibration damping capacity and bearing capacity. Among them, the overall performance of EPTA-MR with a density of 2.5 g·cm−3 was closer to that of the physiologic intervertebral disc. A macro experiment of five million fatigue vibration tests combined with microstructure observation exhibited a wear rate of only 0.9396 g·MC−1, with no noticeable change in the internal micro-morphology. Therefore, the EPTA-MR has a broad application prospect as the nucleus pulposus material of artificial intervertebral disc prosthesis.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Gaffey J L, Ghanayem A J, Voronov M L, Havey R M, Carandang G, Abjornson C, Patwardhan A G. Effect of increasing implant height on lumbar spine kinematics and foraminal size using the ProDisc-L prosthesis. Spine, 2010, 35, 1777–1782.

    Article  Google Scholar 

  2. Formica M, Divano S, Cavagnaro L, Basso M, Zanirato A, Formica C, Felli L. Lumbar total disc arthroplasty: Outdated surgery or here to stay procedure? A systematic review of current literature. Journal of Orthopaedics and Traumatology, 2017, 18, 197–215.

    Article  Google Scholar 

  3. Zigler J E, Delamarter R B. Five-year results of the prospective, randomized, multicenter, Food and Drug Administration investigational device exemption study of the Pro-Disc-L total disc replacement versus circumferential arthrodesis for the treatment of single-level degenerative disc disease. Journal of Neurosurgery: Spine, 2012, 17, 493–501.

    Google Scholar 

  4. Siepe C J, Heider F, Haas E, Hitzl W, Szeimies U, Stabler A, Weiler C, Nerlich A G, Mayer M H. Influence of lumbar intervertebral disc degeneration on the outcome of total lumbar disc replacement: A prospective clinical, histological, X-ray and MRI investigation. European Spine Journal, 2012, 21, 2287–2299.

    Article  Google Scholar 

  5. Meir A R, Freeman B J C, Fraser R D, Fowler S M. Ten-year survival and clinical outcome of the AcroFlex lumbar disc replacement for the treatment of symptomatic disc degeneration. The Spine Journal, 2013, 13, 13–21.

    Article  Google Scholar 

  6. Park J H, Rhim S C, Roh S W. Mid-term follow-up of clinical and radiologic outcomes in cervical total disk replacement (Mobi-C): Incidence of heterotopic ossification and risk factors. Journal of Spinal Disorders & Techniques, 2013, 26, 141–145.

    Article  Google Scholar 

  7. Lemaire J P, Carrier H, Sariali E H, Skalli W, Lavaste F. Clinical and radiological outcomes with the Charité artificial disc: A 10 year minimum follow up. Journal of Spinal Disorders & Techniques, 2005, 18, 353–359.

    Article  Google Scholar 

  8. Nunley P D, Jawahar A, Cavanaugh D A, Gordon C R, Kerr E J, Utter P A. Symptomatic adjacent segment disease after cervical total disc replacement: Re-examining the clinical and radiological evidence with established criteria. The Spine Journal, 2013, 13, 5–12.

    Article  Google Scholar 

  9. Putzier M, Funk J F, Schneider S V, Gross C, Tohtz S W, Khodadadyan-Klostermann C, Perka C, Kandziora F. Charité total disc replacement clinical and radiographical results after an average follow up of 17 years. European Spine Journal, 2006, 15, 183–195.

    Article  Google Scholar 

  10. Bernard L, Vaudaux P, Huggler E, Stern R, Fréhel C, Francois P, Lew D, Hoffmeyer P. Inactivation of a subpopulation of human neutrophils by exposure to ultra-high-molecular-weight polyethylene wear debris. FEMS Immunology and Medical Microbiology, 2007, 49, 425–432.

    Article  Google Scholar 

  11. Galvin A L, Tipper J L, Jennings L M, Stone M H, Jin Z M, Ingham E, Fisher J. Wear and biological activity of highly crosslinked plolyethylene in the hip under low serum protein concentrations. Proceedings of the Institution of Mechanical Engineers, 2007, 221, 1–10.

    Article  Google Scholar 

  12. Hellier W G, Hedman T P, Kostuik J P. Wear studies for development of an intevrertebral disc porsthesis. Spine, 1992, 17, 586–596.

    Article  Google Scholar 

  13. Chen Y J, Feng B, Zhu Y P, Weng J, Wang J X. Fabrication of porous titanium implants with biomechanical compatibility. Materials Letters, 2009, 63, 2659–2661.

    Article  Google Scholar 

  14. Ahn M K, Jo I H, Koha Y H, Kim H E. Production of highly porous titanium (Ti) scaffolds by vacuum-assisted foaming of titanium hydride (TiH2) suspension. Materials Letters, 2014, 120, 228–231.

    Article  Google Scholar 

  15. Jiang G F, He G. Enhancement of the porous titanium with entangled wire structure for load-bearing biomedical applications. Materials & Design, 2014, 56, 241–244.

    Article  Google Scholar 

  16. Kumar A, Nune K C, Misra R D K. Biological functionality and mechanistic contribution of extracellular matrix-ornamented three dimensional Ti-6Al-4V mesh scaffolds. Journal of Biomedical Materials Research Part A, 2016, 104, 2751–2763.

    Article  Google Scholar 

  17. Yan L, Jiang G F, Guo H. Enhancement of entangled porous titanium by BisGMA for load-bearing biomedical applications. Materials Science & Engineering C, 2016, 61, 37–41.

    Article  Google Scholar 

  18. He G, Liu P, Tan Q B. Porous titanium materials with entangled wire structure for load-bearing biomedical applications. Journal of the Mechanical Behavior of Biomedical Materials, 2012, 5, 16–31.

    Article  Google Scholar 

  19. Bai C Y, Wei W B, Hou D M, Dang X Q, Wang K Z. Biomechanical analysis of a new titanium rubber cervical disc prosthesis. Chinese Journal of Spine and Spinal Cord, 2014, 24, 752–756. (in Chinese)

    Google Scholar 

  20. Bai H B, Lu C H, Cao F L. Metal Rubber Materials and Engineering Applications. Science Press, Beijing, China, 2014. (in Chinese)

    Google Scholar 

  21. Yan W T, Zhao G P, Fang X G. Construction and analy sis of a finite element model of human L4-5 lumbar segment. Journal of Biomedical Engineering, 2014, 31, 612–618.

    Google Scholar 

  22. Wang H W, Liu X Y, Wan Y. Construction of a finite element model of human L4∼L5 lumber segment and verification of mechanical. Medicine & Philosophy(B), 2017, 38, 50–53.

    Google Scholar 

  23. Zhang D Y, Scarpa F, Ma Y H, Boba K, Hong J, Lu H W. Compression mechanics of nickel-based superalloy metal rubber. Materials Science and Engineering A, 2013, 580, 305–312.

    Article  Google Scholar 

  24. Huang G S, Hao S L, Liu S L, Li C H. A study on a new artificial lumbar intervertebral disc and its static mechanical tests. Academic Journal of Sun Yat-Sen University of Medical Sciences, 1998, 19, 124–127. (in Chinese)

    Google Scholar 

  25. Zhang J Z, Zhai B, Min Y, Liu B. Functional testing and evaluation tactics of artificial cervical disc prosthesis in vitro. Journal of Tissue Engineering and Reconstructive Surgery, 2018, 14, 61–66. (in Chinese)

    Google Scholar 

  26. Li R, Wang S, Liao Z H, Liu W Q. Research progress on mechanical performance evaluation of artificial intervertebral disc. Journal of Biomedical Engineering, 2018, 35, 493–500. (in Chinese)

    Google Scholar 

  27. Ma Y H, Zhu H X, Zhang D Y, Liu B L, Hong J. Experimental investigation on shape memory alloy metal rubber. Science China-Technological Sciences, 2013, 8, 1949–1955.

    Article  Google Scholar 

  28. Li D W, Bai H B, Pen W, Liu Y J. Damping characteristics of MR cells for spring couplings. Mechanical Science and Technology for Aerospace Engineering, 2006, 3, 265–267. (in Chinese)

    Google Scholar 

  29. Fen P F, Du S Y, Wang D F, Li H T. Fatigue residual stiffness degradation model for composite laminates. Acta Chinese Journal of Solid Mechanics, 2003, 24 46–18. (in Chinese)

    Google Scholar 

  30. Bertagnoli R, Schonmayr R. Surgical and clinical results with the PDN prosthetic disc-nucleus device. European Spine Journal, 2002, 11, S143–S148. (in Chinese)

    Article  Google Scholar 

  31. Korge A, Nydegger T, Polard J, Mayer H, Husson J. A spiral implant as nucleus prosthesis in the lumbar spine. European Spine Journal, 2002, 11, 149–153.

    Article  Google Scholar 

  32. Allen M J, Schoonmaker J E, Bauer T W, Williams P F, P A Higham, Yuan H A. Preclinical evaluation of a poly (vinyl alcohol) hydrogel implant as a replacement for the nucleus pulposus. Spine, 2004, 29, 515–523.

    Article  Google Scholar 

  33. Buttner-Janz K, Schellnack K, Zipple H. Biomechanics of the SB-Charite Lumbar intervertebral disc endoprosthesis. International Orthopaedics, 1989, 13, 173–176.

    Article  Google Scholar 

  34. Prokopovich P, Pemi S, Fisher J, Hall R M. Spatial variation of wear on Charité Lumbar discs. Acta Biomaterialia, 2011, 7, 3914–3926.

    Article  Google Scholar 

  35. Nechtow W, Bushelow M, Hintner M, Ochs A, Kaddick C. Cervical disc prosthesis polyethylene wear following the ISO cervical test. 54th Annual Meeting Orthopaedic Research Society San Francisco, San Francisco, America, 2008, 1926.

  36. Bushelow M, Nechtow W, Hintner M. Wear testing of a cervical total disc replacement: Effect of motion and load parameters on wear rate and particle morphology. 54th Annual Meeting Orthopaedic Research Society, San Francisco, America, 2008, 1925.

Download references

Acknowledgment

The authors thank the National Natural Science Foundation of China (Grant Nos. 51805086 and 51975123), the Fujian Provincial Natural Science Foundation (Grant No. 2019J01210), Fujian Province health education joint project (Grant No. 2019-WJ-01).

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Zhiying Ren or Jie Xu.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ren, Z., Huang, J., Bai, H. et al. Potential Application of Entangled Porous Titanium Alloy Metal Rubber in Artificial Lumbar Disc Prostheses. J Bionic Eng 18, 584–599 (2021). https://doi.org/10.1007/s42235-021-0039-6

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s42235-021-0039-6

Keywords

Navigation