Skip to main content
Log in

Improvement of flexural capacity of hybrid, reinforced concrete spliced girders using steel fiber concrete in splice region and near surface mounted carbon fiber-reinforced polymer bars: experimental investigations

  • Practice-oriented paper
  • Published:
Innovative Infrastructure Solutions Aims and scope Submit manuscript

Abstract

Large span girders (more than 50 m) are difficult to cast as one unit for several conditions, it is better to assemblage them from precast segments in field. This paper aims to investigate the structural behavior of simply supported reinforced concrete spliced girders. Seven beams with 150 × 250 mm rectangular cross section and 2200 mm total length have been cast. The first beam was cast as one unit as a control beam while the other six beams were made from two precast segments spliced at midspan using cast in situ joints. The parameters studied were the existence of splices, joint length, use of steel fiber concrete at joint region, and strengthening the spliced girders using near surface mounted carbon fiber-reinforced polymer NSM-CFRP bars. All beams were tested using four points loading system. The results showed that the existence of splices decreased the flexural capacity of the spliced beam by about 24.1% with larger midspan deflections if compared with the control beam. Also, decrease in joint length by 50% decreased the flexural capacity by 20.1%, 24.1%, and 25.7%. When steel fiber concrete of 1% volume fraction was used at joints, the flexural capacity of the beams increased by 23.4–32.7%. In addition to that, providing the spliced beams with NSM-CFRP bars of amount 50% of the main tension steel reinforcement enhanced the load carrying capacity by 38.5–83.7%. In spite of that, the failure of the beams was rather brittle.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

References

  1. Janssen HH, Spaans L (1994) Record span spliced bulb-tee girders used in highland view bridge. PCI J 39(1):12–19

    Article  Google Scholar 

  2. Ramos G, Casas JR, Alarcón A (2004) Repair and strengthening of segmental bridges using carbon fibers. Eng Struct 26(5):609–618

    Article  Google Scholar 

  3. Turmo J, Ramos G, Aparicio AC (2005) FEM study on the structural behavior of segmental concrete bridges with unbonded prestressing and dry joints: simply supported bridges. Eng Struct 27(11):1652–1661

    Article  Google Scholar 

  4. Huang Z, Liu XL (2006) Modified skew bending model for segmental bridge with unbonded tendons. J Bridge Eng 11(1):59–63

    Article  Google Scholar 

  5. Al-Mamuree A (2008) Analysis of prestressed concrete girders with field splices. PhD thesis, University of Baghdad

  6. Algorafi MA, Ali AAA, Othman I, Jaafar MS, Anwar MP (2010) Experimental study of externally prestressed segmental beam under torsion. Eng Struct 32(11):3528–3538

    Article  Google Scholar 

  7. Mahmoud T, Al-Quraishy Q (2012) Experimental and theoretical investigation for behavior of precast concrete girders with connections. J Eng 18(5):621–638

    Google Scholar 

  8. Saibabu S, Srinivas V, Sasmal S, Lakshmanan N, Iyer N (2013) Performance evaluation of dry and epoxy jointed segmental prestressed box girders under monotonic and cyclic loading. Constr Build Mater 38:931–940

    Article  Google Scholar 

  9. Helal Y, Garcia R, Pilakoutas K, Guadagnini M, Hajirasouliha I (2016) Strengthening of short splices in RC beams using post-tensioned metal straps. Mater Struct 49(1–2):133–147

    Article  Google Scholar 

  10. Yang D, Yi T (2016) Combined shear and bending behavior of joints in precast concrete segmental beams with external tendons. In: The 2016 structures congress

  11. Jiang H, Wei R, Ma Z, Li Y, Jing Y (2016) Shear strength of steel fiber-reinforced concrete dry joints in precast segmental bridges. J Bridge Eng 21(11):04016085

    Article  Google Scholar 

  12. Jiang H, Li Y, Liu A, Ma Z, Chen L, Chen Y (2016) Shear behavior of precast concrete segmental beams with external tendons. J Bridge Eng 23(8):04018049

    Article  Google Scholar 

  13. Al-Tameemi H (2016) Analysis for behavior of spliced R.C. girders strengthened with CFRP laminates. PhD thesis, University of Babylon

  14. Al-Khafaji A, Al-Mamuree A, Abd Aoun A (2018) Improvement of flexural strength of precast concrete spliced girder using reactive powder concrete in splice region. J Eng Struct 14:197–208

    Google Scholar 

  15. ACI Committee 318 (2011) Building code requirements for structural concrete (ACI 318-11) and commentary (ACI 318R-11). American Concrete Institute, Farmington Hills

    Google Scholar 

  16. Yazıcı Ş, ĺnan G, Tabak V (2007) Effect of aspect ratio and volume fraction of steel fiber on the mechanical properties of SFRC. J Constr Build Mater 21:1250–1253

    Article  Google Scholar 

  17. ASTM A615/A615M-05a (2006) Standard specification for deformed and plain billet-steel bars for concrete reinforcement, ASTM committee A01 on steel, stainless steel, and related alloys. West Conshohocken, PA 19428-2959:1–7

  18. ACI Committee 440 (2008) Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures (ACI 440.2R-08), ACI Manual of Concrete Practice, American Concrete Institute, Farming Hills

  19. Jeffrey SR (2003) Prestrectives in civil engineering. Commemorating the 150th anniversary of the American Society of Civil Engineering, ASCE Publications: 375

  20. Muthuswamy KR, Thirugnanam GS (2014) Structural behavior of hybrid fiber reinforced concrete exterior beam-column joint subjected to cyclic loading. Int J Civ Struct Eng 4(3):262–273

    Google Scholar 

  21. Kwan AKH, Ho JCM, Pam HJ (2002) Flexural strength and ductility of reinforced concrete beams. Proc Inst Civ Eng Struct Build 152(4):361–369

    Article  Google Scholar 

  22. Maghsoudi AA, Bengar HA (2011) Acceptable lower bound of the ductility index and serviceability state of RC continuous beams strengthened with CFRP sheets. Sci Iran 18(1):36–44

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Alaa Hassoon.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Hassoon, A., Aljanabi, A. Improvement of flexural capacity of hybrid, reinforced concrete spliced girders using steel fiber concrete in splice region and near surface mounted carbon fiber-reinforced polymer bars: experimental investigations. Innov. Infrastruct. Solut. 5, 71 (2020). https://doi.org/10.1007/s41062-020-00315-w

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s41062-020-00315-w

Keywords

Navigation