Induced Dual-Nanospray: A Novel Internal Calibration Method for Convenient and Accurate Mass Measurement

  • Application Note
  • Published:
Journal of The American Society for Mass Spectrometry

Abstract

Accurate mass information is of great importance in the determination of unknown compounds. An effective and easy-to-control internal mass calibration method will dramatically benefit accurate mass measurement. Here we reported a simple induced dual-nanospray internal calibration device which has the following three advantages: (1) the two sprayers are in the same alternating current field; thus both reference ions and sample ions can be simultaneously generated and recorded. (2) It is very simple and can be easily assembled. Just two metal tubes, two nanosprayers, and an alternating current power supply are included. (3) With the low-flow-rate character and the versatility of nanoESI, this calibration method is capable of calibrating various samples, even untreated complex samples such as urine and other biological samples with small sample volumes. The calibration errors are around 1 ppm in positive ion mode and 3 ppm in negative ion mode with good repeatability. This new internal calibration method opens up new possibilities in the determination of unknown compounds, and it has great potential for the broad applications in biological and chemical analysis.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Figure 1
Figure 2
Figure 3

References

  1. Liu, T., Belov, M.E., Jaitly, N., Qian, W.J., Smith, R.D.: Accurate mass measurements in proteomics. Chem. Rev. 107, 3621–3653 (2007)

    Article  CAS  Google Scholar 

  2. Clauser, K.R., Baker, P., Burlingame, A.L.: Role of accurate mass measurement (10 ppm) in protein identification strategies employing MS or MS/MS and database searching. Anal. Chem. 71, 2871–2882 (1999)

    Article  CAS  Google Scholar 

  3. Russell, D.H., Edmondson, R.D.: High-resolution mass spectrometry and accurate mass measurements with emphasis on the characterization of peptides and proteins by matrix-assisted laser desorption/ionization time-of-ñight mass spectrometry. J. Mass Spectrom. 32, 263–276 (1997)

    Article  CAS  Google Scholar 

  4. Koomen, J.M., Russell, W.K., Tichy, S.E., Russell, D.H.: Accurate mass measurement of DNA oligonucleotide ions using high-resolution time-of-flight mass spectrometry. J. Mass. Spectrom. 37, 357–371 (2002)

    Article  CAS  Google Scholar 

  5. Wenger, C.D., McAlister, G.C., Xia, Q., Coon, J.J.: Sub-part-per-million precursor and product mass accuracy for high-throughput proteomics on an electron transfer dissociation-enabled orbitrap mass spectrometer. Mol. Cell. Proteom. 9, 754–763 (2010)

    Article  CAS  Google Scholar 

  6. Nepomuceno, A.I., Muddiman, D.C., Bergen III, H.R., Craighead, J.R., Burke, M.J., Caskey, P.E., Allan, J.A.: Dual electrospray ionization source for confident generation of accurate mass tags using liquid chromatography Fourier transform ion cyclotron resonance mass spectrometry. Anal. Chem. 75, 3411–3418 (2003)

    Article  CAS  Google Scholar 

  7. Eckers, C., Wolff, J.-C., Haskins, N.J., Sage, A.B., Giles, K., Bateman, R.: Accurate mass liquid chromatography/mass spectrometry on orthogonal acceleration time-of-flight mass analyzers using switching between separate sample and reference sprays. 1. Proof of concept. Anal. Chem. 72, 3683–3688 (2000)

    Article  CAS  Google Scholar 

  8. Wolff, J.-C., Eckers, C., Sage, A.B., Giles, K., Bateman, R.: Accurate mass liquid chromatography/mass spectrometry on quadrupole orthogonal acceleration time-of-flight mass analyzers using switching between separate sample and reference sprays. 2. Applications using the dual-electrospray ion source. Anal. Chem. 73, 2605–2612 (2001)

    Article  CAS  Google Scholar 

  9. Satomi, Y., Kudo, Y., Sasaki, K., Hase, T., Takao, T.: Accurate mass measurement in nano-electrospray ionization mass spectrometry by alternate switching of high voltage between sample and reference sprayers. Rapid Commun. Mass Spectrom. 19, 540–546 (2005)

    Article  CAS  Google Scholar 

  10. Bowers, J.J., Zimmerman, J.R., Oglesbee, R.A., McLuckey, S.A.: Adjacent pulsed nanoelectrospray ionization emitters for the alternating generation of ions of opposite polarity. Anal. Chem. 82, 1147–1150 (2010)

    Article  CAS  Google Scholar 

  11. Schneider, B.B., Covey, T.R.: Calibrant delivery for mass spectrometry. J. Am. Soc. Mass Spectrom. 18, 991–996 (2007)

    Article  CAS  Google Scholar 

  12. Young, N.L., Sisto, M.C., Young, M.N., Grant, P.G., Killilea, D.W., LaMotte, L.T., Wu, K.J.J., Lebrilla, C.B.: Steady-state asymmetric nanospray dual ion source for accurate mass determination within a chromatographic separation. Anal. Chem. 79, 5711–5718 (2007)

    Article  CAS  Google Scholar 

  13. Chambers, A.G., Ramsey, J.M.: Microfluidic dual emitter electrospray ionization source for accurate mass measurements. Anal. Chem. 84, 1446–1451 (2012)

    Article  CAS  Google Scholar 

  14. Jiang, L., Moini, M.: Development of multi-ESI-sprayer, multi-atmospheric-pressure-inlet mass spectrometry and its application to accurate mass measurement using time-of-flight mass spectrometry. Anal. Chem. 72, 20–24 (2000)

    Article  CAS  Google Scholar 

  15. Maheshwari, S., Chetwani, N., Chang, H.-C.: Universal cone angle of ac electrosprays due to net charge entrainment. Phys. Rev. Lett. 101, 204501 (2008)

    Article  Google Scholar 

  16. Stark, A.K., Schilling, M., Janasek, D., Franzke, J.: Characterization of dielectric barrier electrospray ionization for mass spectrometric detection. Anal. Bioanal. Chem. 397, 1767–1772 (2010)

    Article  CAS  Google Scholar 

  17. Stark, A.K., Meyer, C., Kraehling, T., Jestel, G., Marggraf, U., Schilling, M., Janasek, D., Franzke, J.: Electronic coupling and scaling effects during dielectric barrier electrospray ionization. Anal. Bioanal. Chem. 400, 561–569 (2011)

    Article  CAS  Google Scholar 

  18. Qiao, L., Sartor, R., Gasilova, N., Lu, Y., Tobolkina, E., Liu, B., Girault, H.H.: Electrostatic-spray ionization mass spectrometry. Anal. Chem. 84, 7422–7430 (2012)

    Article  CAS  Google Scholar 

  19. Huang, G., Li, G., Ducan, J., Ouyang, Z., Cooks, R.G.: Synchronized inductive desorption electrospray ionization mass spectrometry. Angew. Chem. Int. Ed. 50, 2503–2506 (2011)

    Article  CAS  Google Scholar 

  20. Huang, G., Li, G., Cooks, R.G.: Induced nanoelectrospray ionization for matrix-tolerant and high-throughput mass spectrometry. Angew. Chem. Int. Ed. 50, 9907–9910 (2011)

    Article  CAS  Google Scholar 

  21. Schmidt, A., Karas, M., Dülcks, T.: Effect of different solution flow rates on analyte ion signals in nano-ESI MS, or: when does ESI turn into nano-ESI? J. Am. Soc. Mass Spectrom. 14, 492–500 (2003)

    Article  CAS  Google Scholar 

  22. Wong, S., Meng, C., Fenn, J.: Multiple charging in electrospray ionization of poly (ethylene glycols). J. Phys. Chem. 92, 546–550 (1988)

    Article  CAS  Google Scholar 

  23. Cody, R.B., Tamura, J., Musselman, B.D.: Electrospray ionization/magnetic sector mass spectrometry: calibration, resolution, and accurate mass measurements. Anal. Chem. 64, 1561–1570 (1992)

    Article  CAS  Google Scholar 

  24. Mark, L.P., Gill, M.C., Mahut, M., Derrick, P.J.: Dual nano-electrospray for probing solution interactions and fast reactions of complex biomolecules. Eur. J. Mass Spectrom. (Chichester, Eng) 18, 439–446 (2012)

    Article  CAS  Google Scholar 

  25. Lu, Y., Liu, F., Lion, N., Girault, H.H.: Dual-channel electrospray microchip. J. Am. Soc. Mass Spectrom. 24, 454–457 (2013)

    Article  CAS  Google Scholar 

Download references

Acknowledgment

Financial support from the National Natural Science Foundation of China (no. 21127901, 21175139, and 21205123), and the Chinese Academy of Sciences is gratefully acknowledged.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Zongxiu Nie.

Electronic supplementary material

Below is the link to the electronic supplementary material.

ESM 1

(DOCX 1422 kb)

Rights and permissions

Reprints and permissions

About this article

Cite this article

Li, Y., Zhang, N., Zhou, Y. et al. Induced Dual-Nanospray: A Novel Internal Calibration Method for Convenient and Accurate Mass Measurement. J. Am. Soc. Mass Spectrom. 24, 1446–1449 (2013). https://doi.org/10.1007/s13361-013-0670-5

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s13361-013-0670-5

Key words

Navigation