Abstract
Sufficiently long reaction time and low flow velocity are crucial for capillary microfluidic immunoassay chips, especially for truly “one-step” detection with continuous on-chip labelling and capturing. In this study, a multistory stairs-based new delay valve is used to meet the time and flow requirements for protein testing. The delay strategy is capable of slowing down the flow of liquid into the functional region and delaying the time out of the regions as well, thus extending the labelling and capture time to about 100 and 60 s respectively, and further reducing the flow velocity to below 8 μL/min. Based on the principle of sandwich-like immunocomplex, the designed chip is capable of automatically accomplishing on-chip mixing, labelling and capturing procedures via once sample loading and sensitively detecting human Alpha-Fetoprotein (AFP) in 40 μL serum with a wide dynamic ranging from 10 ng/mL to 10 000 ng/mL within 5 min. It could be foreseeable that this microchip has great potential in biomarkers clinical testing.
Similar content being viewed by others
References
Herzog, C., Poehler, E., Peretzki, A.J., Borisov, S.M., Aigner, D., Mayr, T., Nagl, S.: Continuous on-chip fluorescence labelling, free-flow isoelectric focusing and marker-free isoelectric point determination of proteins and peptides. Lab Chip 16, 1565–1572 (2016)
Liang, C., Liu, Y., Niu, A., Liu, C., Li, J., Ning, D.: Smartphone-app based point-of-care testing for myocardial infarction biomarker cTnI using an autonomous capillary microfluidic chip with self-aligned on-chip focusing (SOF) lenses. Lab Chip 19, 1797–1807 (2019)
Dziomba, S., Araya-Farias, M., Smadja, C., Taverna, M., Carbonnier, B., Tran, N.T.: Solid supports for extraction and preconcentration of proteins and peptides in microfluidic devices: a review. Anal Chim Acta 955, 1–26 (2017)
Manz, A., Harrison, D.J., Verpoorte, E.M.J., Fettinger, J.C., Paulus, A., Lüdi, H., Widmer, H.M.: Planar chips technology for miniaturization and integration of separation techniques into monitoring systems: Capillary electrophoresis on a chip. J. Chromatogr. A 593, 253–258 (1992)
Schonhorn, J.E., Fernandes, S.C., Rajaratnam, A., Deraney, R.N., Rolland, J.P., Mace, C.R.: A device architecture for three-dimensional, patterned paper immunoassays. Lab Chip 14, 4653–4658 (2014)
Li, J., Macdonald, J.: Multiplexed lateral flow biosensors: Technological advances for radically improving point-of-care diagnoses. Biosens. Bioelectron. 83, 177–192 (2016)
Han, K.N., Li, C.A., Seong, G.H.: Microfluidic chips for immunoassays. Annu. Rev. Anal. Chem. (Palo Alto Calif.) 6, 119–141 (2013)
Li, X., Pan, X. M., Lu, J. M., Zhou, Y. P., Gong, J. M.: Dual-modal visual/photoelectrochemical all-in-one bioassay for rapid detection of AFP using 3D printed microreactor device. Biosens. Bioelectron. 158, 112158 (2020).
He, X. Y., Ge, C., Zheng, X. Q., Tang, B., Chen, L., Li, S. B., Wang, L., Zhang, L. Q., Xu, Y.: Rapid identification of alpha-fetoprotein in serum by a microfluidic SERS chip integrated with Ag/Au nanocomposites. Sens. Actuator B-Chem. 317, 128196 (2020).
Huang, C.H., Wang, B.X., Chen, Y.Y., Jin, G.: Label-free immunoassay of carcinoembryonic antigen by microfluidic channel biosensor based on imaging ellipsometry and its clinic application. Integr. Ferroelectr. 209, 19–29 (2020)
Jiao, Y. C., Du, C., Zong, L. J., Guo, X. Y., Han, Y. F., Zhang, X. P., Li, L., Zhang, C. W., Ju, Q., Liu, J. H., Yu, H. D., Huang, W.: 3D vertical-flow paper-based device for simultaneous detection of multiple cancer biomarkers by fluorescent immunoassay. Sens. Actuator B-Chem. 306, 127239 (2020).
Chen, J.-S., Chen, P.-F., Lin, H.T.-H., Huang, N.-T.: A Localized surface plasmon resonance (LSPR) sensor integrated automated microfluidic system for multiplex inflammatory biomarker detection. Analyst 145, 7654–7661 (2020)
Sohrabi, H., Kordasht, H. K., Pashazadeh-Panahi, P., Nezhad-Mokhtari, P., Hashemzaei, M., Majidi, M. R., Mosafer, J., Oroojalian, F., Mokhtarzadeh, A., de la Guardia, M.: Recent advances of electrochemical and optical biosensors for detection of C-reactive protein as a major inflammatory biomarker. Microchem. J. 158, 105287 (2020).
Sanjay, S.T., Fu, G., Dou, M., Xu, F., Liu, R., Qi, H., Li, X.: Biomarker detection for disease diagnosis using cost-effective microfluidic platforms. Analyst 140, 7062–7081 (2015)
Wang, W., Cai, X., Li, Q., Zheng, L., Yu, X., Zhang, H., Wang, J.: Application of a microfluidic paper-based bioimmunosensor with laser-induced fluorescence detection in the determination of alpha-fetoprotein from serum of hepatopaths. Talanta 221, 121660 (2021).
Guo, X., Zong, L., Jiao, Y., Han, Y., Zhang, X., Xu, J., Li, L., Zhang, C.W., Liu, Z., Ju, Q., Liu, J., Xu, Z., Yu, H.D., Huang, W.: Signal-enhanced detection of multiplexed cardiac biomarkers by a paper-based fluorogenic immunodevice integrated with zinc oxide nanowires. Anal. Chem. 91, 9300–9307 (2019)
Devi, R.V., Doble, M., Verma, R.S.: Nanomaterials for early detection of cancer biomarker with special emphasis on gold nanoparticles in immunoassays/sensors. Biosens. Bioelectron. 68, 688–698 (2015)
Olanrewaju, A., Beaugrand, M., Yafia, M., Juncker, D.: Capillary microfluidics in microchannels: from microfluidic networks to capillaric circuits. Lab Chip 18, 2323–2347 (2018)
Lin, Y.H., Wu, C.C., Peng, Y.S., Wu, C.W., Chang, Y.T., Chang, K.P.: Detection of anti-p53 autoantibodies in saliva using microfluidic chips for the rapid screening of oral cancer. RSC Adv. 8, 15513–15521 (2018)
Hess, J.F., Zehnle, S., Juelg, P., Hutzenlaub, T., Zengerle, R., Paust, N.: Review on pneumatic operations in centrifugal microfluidics. Lab Chip 19, 3745–3770 (2019)
Clime, L., Daoud, J., Brassard, D., Malic, L., Geissler, M., Veres, T.: Active pumping and control of flows in centrifugal microfluidics. Microfluid. Nanofluid. 23, 3 (2019)
Weigl, B., Domingo, G., LaBarre, P., Gerlach, J.: Towards non- and minimally instrumented, microfluidics-based diagnostic devices. Lab Chip 8, 1999–2014 (2008)
Eijkel, J.C.T., van den Berg, A.: Active transport: a new chemical separation method? Lab Chip 6, 597–600 (2006)
Zimmermann, M., Hunziker, P., Delamarche, E.: Valves for autonomous capillary systems. Microfluid. Nanofluid. 5, 395–402 (2008)
Safavieh, R., Juncker, D.: Capillarics: pre-programmed, self-powered microfluidic circuits built from capillary elements. Lab Chip 13, 4180–4189 (2013)
Juncker, D., Schmid, H., Drechsler, U., Wolf, H., Wolf, M., Michel, B., de Rooij, N., Delamarche, E.: Autonomous microfluidic capillary system. Anal. Chem. 74, 6139–6144 (2002)
Lutz, B., Liang, T., Fu, E., Ramachandran, S., Kauffman, P., Yager, P.: Dissolvable fluidic time delays for programming multi-step assays in instrument-free paper diagnostics. Lab Chip 13, 2840–2847 (2013)
Glière, A., Delattre, C.: Modeling and fabrication of capillary stop valves for planar microfluidic systems. Sens. Actuators A 130–131, 601–608 (2006)
Zhang, L., Jones, B., Majeed, B., Nishiyama, Y., Okumura, Y. & Stakenborg, T.: Study on stair-step liquid triggered capillary valve for microfluidic systems. J. Micromech. Microeng. 28, 065005 (2018).
Chang, N., Zhai, J., Liu, B., Zhou, J., Zeng, Z., Zhao, X.: Low cost 3D microfluidic chips for multiplex protein detection based on photonic crystal beads. Lab Chip 18, 3638–3644 (2018)
Wang, T., Zhang, K.H.: New blood biomarkers for the diagnosis of AFP-negative hepatocellular carcinoma. Front. Oncol. 10, 1316 (2020)
Lin, Q., Wu, J., Fang, X., Kong, J.: Washing-free centrifugal microchip fluorescence immunoassay for rapid and point-of-care detection of protein. Anal. Chim. Acta 1118, 18–25 (2020)
Zhou, B., Xu, W., Syed, A.A., Chau, Y., Chen, L., Chew, B., Yassine, O., Wu, X., Gao, Y., Zhang, J., Xiao, X., Kosel, J., Zhang, X.-X., Yao, Z., Wen, W.: Design and fabrication of magnetically functionalized flexible micropillar arrays for rapid and controllable microfluidic mixing. Lab Chip 15, 2125–2132 (2015)
Pawinanto, R. E., Yunas, J., Hashim, A. M.: Micropillar based active microfluidic mixer for the detection of glucose concentration. Microelectron. Eng. 234, 111452 (2020).
Rashid, F., Glover, P.W.J., Lorinczi, P., Hussein, D., Lawrence, J.A.: Microstructural controls on reservoir quality in tight oil carbonate reservoir rocks. J. Petrol. Sci. Eng. 156, 814–826 (2017)
Acknowledgements
This work was funded by the Key Research and Development Plan Project of Anhui Province (No. 1704a0802157) and the Key-Area Research and Development Program of Guangdong Province (No. 2019B020219003).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Gao, N., Chang, J., Zhu, Z. et al. Multistory Stairs-based, Fast and Point-of-care Testing for Disease Biomarker Using One-step Capillary Microfluidic Fluoroimmunoassay Chip via Continuous On-chip Labelling. BioChip J 15, 268–275 (2021). https://doi.org/10.1007/s13206-021-00025-0
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s13206-021-00025-0