Skip to main content
Log in

TKA Sagittal Alignment with Navigation Systems and Conventional Techniques Vary Only a Few Degrees

  • Original Article
  • Published:
Clinical Orthopaedics and Related Research

Abstract

Navigation systems have been developed to achieve more reliable prosthetic alignment in TKAs. However, the component alignment in the sagittal plane is reportedly less reliable than in the coronal plane even with navigation systems. We measured and compared sagittal prosthetic alignments for TKAs with the conventional technique and three navigation approaches to establish reference frames, using radiographs of the entire lower extremity while standing. The sagittal alignments simulated on the radiographs with the conventional technique and navigation systems differed by a mean of 2° to 4°. Use of navigation systems resulted in a mean of 1° to 4° hyperextension between the femoral and tibial components and use of the conventional technique resulted in a mean of 1° flexion. Use of different reference points on the distal femoral condyle for the navigation systems resulted in differences of as much as 3° alignment in the sagittal plane. Although optimal prosthetic alignment for TKA in the sagittal plane is unknown, surgeons and technicians using navigation systems should be aware of this difference in the sagittal plane and the risk of hyperextension between the femoral and tibial components, which might be associated with osteolysis and anterior post-cam impingement.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2A–B

Similar content being viewed by others

References

  1. Berger RA, Rubash HE, Seel MJ, Thompson WH, Crossett LS. Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res. 1993;286:40–47.

    PubMed  Google Scholar 

  2. Callaghan JJ, O’Rourke MR, Goetz DD, Schmalzried TP, Campbell PA, Johnston RC. Tibial post impingement in posterior-stabilized total knee arthroplasty. Clin Orthop Relat Res. 2002;404:83–88.

    Article  PubMed  Google Scholar 

  3. Chauhan SK, Clark GW, Lloyd S, Scott RG, Breidahl W, Sikorski JM. Computer-assisted total knee replacement: a controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT Protocol). J Bone Joint Surg Br. 2004;86:818–823.

    Article  PubMed  CAS  Google Scholar 

  4. Collier MB, Engh CA Jr, McAuley JP, Ginn SD, Engh GA. Osteolysis after total knee arthroplasty: influence of tibial baseplate surface finish and sterilization of polyethylene insert. Findings at five to ten years postoperatively. J Bone Joint Surg Am. 2005;87:2702–2708.

    Article  PubMed  Google Scholar 

  5. Egol KA, Chang EY, Cvitkovic J, Kummer FJ, Koval KJ. Mismatch of current intramedullary nails with the anterior bow of the femur. J Orthop Trauma. 2004;18:410–415.

    Article  PubMed  Google Scholar 

  6. Jeffery RS, Morris RW, Denham RA. Coronal alignment after total knee replacement. J Bone Joint Surg Br. 1991;73:709–714.

    PubMed  CAS  Google Scholar 

  7. Kim YH, Kim JS, Yoon SH. Alignment and orientation of the components in total knee replacement with and without navigation support: a prospective, randomised study. J Bone Joint Surg Br. 2007;89:471–476.

    Article  PubMed  Google Scholar 

  8. Li G, Papannagari R, Most E, Park SE, Johnson T, Tanamal L, Rubash HE. Anterior tibial post impingement in a posterior stabilized total knee arthroplasty. J Orthop Res. 2005;23:536–541.

    Article  PubMed  Google Scholar 

  9. Massin P, Gournay A. Optimization of the posterior condylar offset, tibial slope, and condylar roll-back in total knee arthroplasty. J Arthroplasty. 2006;21:889–896.

    Article  PubMed  Google Scholar 

  10. Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C. A prospective, randomized study of computer-assisted and conventional total knee arthroplasty: three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am. 2007;89:236–243.

    Article  PubMed  Google Scholar 

  11. Minoda Y, Kobayashi A, Iwaki H, Sugama R, Iwakiri K, Kadoya Y, Ohashi H, Takaoka K. Sagittal alignment of the lower extremity while standing in Japanese male. Arch Orthop Trauma Surg. 2008;128:435–442.

    Article  PubMed  Google Scholar 

  12. Oswald MH, Jakob RP, Schneider E, Hoogewoud HM. Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplasty. 1993;8:419–426.

    Article  PubMed  CAS  Google Scholar 

  13. Sato T, Koga Y, Omori G. Three-dimensional lower extremity alignment assessment system: application to evaluation of component position after total knee arthroplasty. J Arthroplasty. 2004;19:620–628.

    Article  PubMed  Google Scholar 

  14. Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A. Positioning of total knee arthroplasty with and without navigation support: a prospective, randomised study. J Bone Joint Surg Br. 2003;85:830–835.

    PubMed  CAS  Google Scholar 

  15. Stulberg SD. How accurate is current TKR instrumentation? Clin Orthop Relat Res. 2003;416:177–184.

    Article  PubMed  Google Scholar 

  16. Tew M, Waugh W. Tibiofemoral alignment and the results of knee replacement. J Bone Joint Surg Br. 1985;67:551–556.

    PubMed  CAS  Google Scholar 

  17. Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG. Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res. 1994;299:31–43.

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yukihide Minoda MD, PhD.

Additional information

Each author certifies that he or she has no commercial associations (eg, consultancies, stock ownership, equity interest, patent/licensing arrangements, etc) that might pose a conflict of interest in connection with the submitted article.

Each author certifies that his or her institution has approved the human protocol for this investigation, that all investigations were conducted in conformity with ethical principles of research, and that informed consent for participation in the study was obtained.

About this article

Cite this article

Minoda, Y., Kobayashi, A., Iwaki, H. et al. TKA Sagittal Alignment with Navigation Systems and Conventional Techniques Vary Only a Few Degrees. Clin Orthop Relat Res 467, 1000–1006 (2009). https://doi.org/10.1007/s11999-008-0449-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11999-008-0449-3

Keywords

Navigation