Extensive research has been carried out for improved sensitivity of electroactive biofilm-based sensor (EAB-sensor), which is recognized as a useful tool in water quality early-warning. Antibiotic that is employed widely to treat infection has been proved feasible in this study to regulate the EAB and to increase the EAB-biosensor’s sensitivity. A novel composite electrode was prepared using azithromycin (AZM) and graphite powder (GP), namely AZM@GP electrode, and was employed as the anode in EAB-biosensor. Different dosages of AZM, i.e., 2 mg, 4 mg, and 8 mg, referred to as 0.25%, 0.5% and 1% AZM@GP were under examination. Results showed that EAB-biosensor was greatly benefited from appropriate dosage of AZM (0.5% AZM@GP) with reduced start-up time period, comparatively higher voltage output, more readable electrical signal and increased inhibition rate (30%–65% higher than control sensor with GP electrode) when exposing to toxic formaldehyde. This may be attributed to the fact that AZM inhibited the growth of non-EAM without much influence on the physiologic or metabolism activities of EAM under proper dosage. Further investigation of the biofilm morphology and microbial community analysis suggested that the biofilm formation was optimized with reduced thickness and enriched Geobacter with 0.5% AZM@GP dosage. This novel electrode is easily fabricated and equipped, and therefore would be a promising way to facilitate the practical application of EAB-sensors.
Similar content being viewed by others
References
Adekunle A, Raghavan V, Tartakovsky B (2019). On-line monitoring of heavy metals-related toxicity with a microbial fuel cell biosensor. Biosensors & Bioelectronics, 132: 382–390
Antonacci A, Scognamiglio V (2020). Biotechnological advances in the design of algae-based biosensors. Trends in Biotechnology, 38(3): 334–347
Attili A R, Preziuso S, Ngu Ngwa V, Cantalamessa A, Moriconi M, Cuteri V (2016). Clinical evaluation of the use of enrofloxacin against Staphylococcus aureus clinical mastitis in sheep. Small Ruminant Research, 136: 72–77
Catania C, Karbelkar A A, Furst A L (2021). Engineering the interface between electroactive bacteria and electrodes. Joule, 5(4): 743–747
Cheng S, Xing D, Call D F, Logan B E (2009). Direct biological conversion of electrical current into methane by electromethanogenesis. Environmental Science & Technology, 43(10): 3953–3958
Dong S, Yin C, Chen X (2020). Toxicity-oriented water quality engineering. Frontiers of Environmental Science & Engineering, 14(5): 80
Ejeian F, Etedali P, Mansouri-Tehrani H A, Soozanipour A, Low Z X, Asadnia M, Taheri-Kafrani A, Razmjou A (2018). Biosensors for wastewater monitoring: A review. Biosensors & Bioelectronics, 118: 66–79
Hackbarth M, Jung T, Reiner J E, Gescher J, Horn H, Hille-Reichel A, Wagner M (2020). Monitoring and quantification of bioelectrochemical Kyrpidia spormannii biofilm development in a novel flow cell setup. Chemical Engineering Journal, 390: 124604
Jiang Y, Chu N, Zeng R J (2019). Submersible probe type microbial electrochemical sensor for volatile fatty acids monitoring in the anaerobic digestion process. Journal of Cleaner Production, 232: 1371–1378
Jiang Y, Liang P, Liu P, Miao B, Bian Y, Zhang H, Huang X (2017). Enhancement of the sensitivity of a microbial fuel cell sensor by transient-state operation. Environmental Science. Water Research & Technology, 3(3): 472–479
Li T, Chen F, Zhou Q, Wang X, Liao C, Zhou L, Wan L, An J, Wan Y, Li N (2020a). Unignorable toxicity of formaldehyde on electroactive bacteria in bioelectrochemical systems. Environmental Research, 183: 109143
Li T, Liao C, An J, Zhou L, Tian L, Zhou Q, Li N, Wang X (2021). A highly sensitive bioelectrochemical toxicity sensor and its evaluation using immediate current attenuation. Science of the Total Environment, 766: 142646
Li T, Zhou Q, Zhou L, Yan Y, Liao C, Wan L, An J, Li N, Wang X (2020b). Acetate limitation selects Geobacter from mixed inoculum and reduces polysaccharide in electroactive biofilm. Water Research, 177: 115776
Lu H, Yu Y, Zhou Y, Xing F (2019). A quantitative evaluation method for wastewater toxicity based on a microbial fuel cell. Ecotoxicology and Environmental Safety, 183(2019): 109589
Logan B E, Rossi R, Ragab A, Saikaly P E (2019). Electroactive microorganisms in bioelectrochemical systems. Nature Reviews. Microbiology, 17(5): 307–319
Lovley D R (2008). The microbe electric: Conversion of organic matter to electricity. Current Opinion in Biotechnology, 19(6): 564–571
Pan J, Hu J, Liu B, Li J, Wang D, Bu C, Wang X, Xiao K, Liang S, Yang J, Hou H (2020). Enhanced quorum sensing of anode biofilm for better sensing linearity and recovery capability of microbial fuel cell toxicity sensor. Environmental Research, 181: 108906
Peng X, Yu H, Wang X, Zhou Q, Zhang S, Geng L, Sun J, Cai Z (2012). Enhanced performance and capacitance behavior of anode by rolling Fe3O4 into activated carbon in microbial fuel cells. Bioresource Technology, 121: 450–453
Pentassuglia S, Agostino V, Tommasi T (2018). Encyclopedia of Interfacial Chemistry. Wandelt, K. (ed). Oxford: Elsevier, 110–123
Qi X, Liu P, Liang P, Hao W, Li M, Huang X (2019). Dual-signal-biosensor based on luminescent bacteria biofilm for real-time online alert of Cu(II) shock. Biosensors & Bioelectronics, 142: 111500
Qi X, Liu P, Liang P, Hao W, Li M, Li Q, Zhou Y, Huang X (2020a). Biofilm’s morphology design for high sensitivity of bioelectrochemical sensor: An experimental and modeling study. Science of the Total Environment, 729: 138908
Qi X, Wang S, Li T, Wang X, Jiang Y, Zhou Y, Zhou X, Huang X, Liang P (2021). An electroactive biofilm-based biosensor for water safety: Pollutants detection and early-warning. Biosensors & Bioelectronics, 173: 112822
Reguera G, McCarthy K D, Mehta T, Nicoll J S, Tuominen M T, Lovley D R (2005). Extracellular electron transfer via microbial nanowires. Nature, 435(7045): 1098–1101
Ren L, McCuskey S R, Moreland A, Bazan G C, Nguyen T Q (2019). Tuning Geobacter sulfurreducens biofilm with conjugated polyelectrolyte for increased performance in bioelectrochemical system. Biosensors & Bioelectronics, 144: 111630
Schröder U, Harnisch F, Angenent L T (2015). Microbial electrochemistry and technology: Terminology and classification. Energy & Environmental Science, 8(2): 513–519
Shi L, Dong H, Reguera G, Beyenal H, Lu A, Liu J, Yu H Q, Fredrickson J K (2016). Extracellular electron transfer mechanisms between microorganisms and minerals. Nature Reviews. Microbiology, 14(10): 651–662
Souza M J E, Bittencourt C F, Filho P D S E S (2004). Microbiological assay for enrofloxacin injection. International Journal of Pharmaceutics, 271(1): 287–291
Sui M, Li Y, Jiang Y, Zhang Y, Wang L, Zhang W, Wang X (2021). Light exposure interferes with electroactive biofilm enrichment and reduces extracellular electron transfer efficiency. Water Research, 188: 116512
Summers Z M, Fogarty H E, Leang C, Franks A E, Malvankar N S, Lovley D R (2010). Direct exchange of electrons within aggregates of an evolved syntrophic coculture of anaerobic bacteria. Science, 330(6009): 1413–1415
Tarushi A, Raptopoulou C P, Psycharis V, Terzis A, Psomas G, Kessissoglou D P (2010). Zinc(II) complexes of the second-generation quinolone antibacterial drug enrofloxacin: Structure and DNA or albumin interaction. Bioorganic & Medicinal Chemistry, 18(7): 2678–2685
Wasito H, Fatoni A, Hermawan D, Susilowati S S (2019). Immobilized bacterial biosensor for rapid and effective monitoring of acute toxicity in water. Ecotoxicology and Environmental Safety, 170: 205–209
Wen Q, Kong F, Zheng H, Cao D, Ren Y, Yin J (2011). Electricity generation from synthetic penicillin wastewater in an air-cathode single chamber microbial fuel cell. Chemical Engineering Journal, 168(2): 572–576
Wu D, Sun F, Chua F J D, Zhou Y (2020). Enhanced power generation in microbial fuel cell by an agonist of electroactive biofilm-Sulfamethoxazole. Chemical Engineering Journal, 384: 123238
Yi X, Gao Z, Liu L, Zhu Q, Hu G, Zhou X (2020). Acute toxicity assessment of drinking water source with luminescent bacteria: Impact of environmental conditions and a case study in Luoma Lake, East China. Frontiers of Environmental Science & Engineering, 14(6): 109
Yu D, Zhai J, Liu C, Zhang X, Bai L, Wang Y, Dong S (2017). Small microbial three-electrode cell based biosensor for online detection of acute water toxicity. ACS Sensors, 2(11): 1637–1643
Zhou L, Li T, An J, Liao C, Li N, Wang X (2017). Subminimal inhibitory concentration (sub-MIC) of antibiotic induces electroactive biofilm formation in bioelectrochemical systems. Water Research, 125: 280–287
Acknowledgements
This work was supported by the National Natural Science Foundation of China (Grant No. 52125001).
Author information
Authors and Affiliations
Corresponding authors
Additional information
Highlights
• Antibiotic azithromycin employed in graphite electrode for EAB biosensor.
• Azithromycin at 0.5% dosage increased the sensitivity for toxic formaldehyde.
• Azithromycin increased the relative abundance of Geobacter.
• Azithromycin regulated thickness of electroactive biofilm.