Abstract
Computed tomography coronary angiography (CTCA) has become a cornerstone in the diagnostic process of the heart disease. Although the cardiac imaging with interventional procedures is responsible for approximately 40% of the cumulative effective dose in medical imaging, a relevant radiation dose reduction over the last decade was obtained, with the beginning of the sub-mSv era in CTCA. The main technical basis to obtain a radiation dose reduction in CTCA is the use of a low tube voltage, the adoption of a prospective electrocardiogram-triggering spiral protocol and the application of the tube current modulation with the iterative reconstruction technique. Nevertheless, CTCA examinations are characterized by a wide range of radiation doses between different radiology departments. Moreover, the dose exposure in CTCA is extremely important because the benefit–risk calculus in comparison with other modalities also depends on it. Finally, because anatomical evaluation not adequately predicts the hemodynamic relevance of coronary stenosis, a low radiation dose in routine CTCA would allow the greatest use of the myocardial CT perfusion, fractional flow reserve-CT, dual-energy CT and artificial intelligence, to shift focus from morphological assessment to a comprehensive morphological and functional evaluation of the stenosis. Therefore, the aim of this work is to summarize the correct use of the technical basis in order that CTCA becomes an established examination for assessment of the coronary artery disease with low radiation dose.
Similar content being viewed by others
References
Stocker T, Deseive S, Chen M et al (2017) Rationale and design of the worldwide prospective multicenter registry on radiation dose estimates of cardiac CT angiography in daily practice in 2017 (PROTECTION VI). J Cardiovasc Comput Tomogr 12:81–85
Trattner S, Halliburton S, Thompson C et al (2018) Cardiac-specific conversion factors to estimate radiation effective dose from dose-length product in computed tomography. JACC Cardiovasc Imaging 11:64–74
Williams M, Stewart C, Weir N et al (2019) Using radiation safely in cardiology: what imagers need to know. Heart 105:798–806
Lim K, Ha H, Hwang H et al (2016) Feasibility of high-pitch dual-source low-dose chest CT: reduction of radiation and cardiac artifacts. Diagn Interv Imaging 97:443–449
Stocker T, Deseive S, Leipsic J et al (2018) Reduction in radiation exposure in cardiovascular computed tomography imaging: results from the PROspective multicenter registry on radiation dose estimates of cardiac CT angIOgraphy iN daily practice in 2017 (PROTECTION VI). Eur Heart J 39:3715–3723
Iyama Y, Nakaura T, Kidoh M et al (2016) Submillisievert radiation dose coronary CT angiography: clinical impact of the knowledge-based iterative model reconstruction. Acad Radiol 23:1393–1401
Schicchi N, Fogante M, Esposto Pirani P et al (2019) Third-generation dual-source dual-energy CT in pediatric congenital heart disease patients: state-of-the-art. Radiol Med 124:1238–1252
Nicol ED, Norgaard BL, Blanke P et al (2019) The future of cardiovascular computed tomography: advanced analytics and clinical insights. JACC Cardiovasc Imaging 12:1058–1072
Kim R, Park EA, Lee W et al (2016) Feasibility of 320-row area detector CT coronary angiography using 40 mL of contrast material: assessment of image quality and diagnostic accuracy. Eur Radiol 26:3802–3810
Richards CE, Dorman S, John P et al (2018) Low-radiation and high image quality coronary computed tomography angiography in “real-world” unselected patients. World J Radiol 10:135–142
Do TD, Rheinheimer S, Kauczor HU et al (2020) Image quality evaluation of dual-layer spectral CT in comparison to single-layer CT in a reduced-dose setting. Eur Radiol [Online ahead of print]
Li R, Hou C, Zhou H et al (2020) Comparison on radiation effective dose and image quality of right coronary artery on prospective ECG-gated method between 320 row CT and 2nd generation (128-slice) dual source CT. J Appl Clin Med Phys [Online ahead of print]
Xia C, Vonder M, Pelgrim GJ et al (2020) High-pitch dual-source CT for coronary artery calcium scoring: a head-to-head comparison of non-triggered chest versus triggered cardiac acquisition. J Cardiovasc Comput Tomogr [Online ahead of print]
Schicchi N, Fogante M, Oliva M et al (2019) Radiation dose and image quality with new protocol in lower extremity computed tomography angiography. Radiol Med 124:184–190
Flohr TG, De Cecco CN, Schmidt B et al (2015) Computed tomographic assessment of coronary artery disease: state-of-the-art imaging techniques. Radiol Clin North Am 53:271–285
Mousavi-Gazafroudi S, Sajjadieh-Khajouei A, Moradi M et al (2019) Evaluation of image quality and radiation dose in low tube voltage coronary computed tomography angiography. ARYA Atheroscler 15:205–210
Lin CT, Chu L, Zimmerman S et al (2020) High-pitch non-gated scans on the second and third generation dual-source CT scanners: comparison of coronary image quality. Clin Imaging 59:45–49
Chaosuwannakit N, Makarawate P (2018) Reduction of radiation dose for coronary computed tomography angiography using prospective electrocardiography-triggered high-pitch acquisition in clinical routine. Pol J Radiol 8:e260–e267
Schicchi N, Mari A, Fogante M et al (2019) In vivo radiation dosimetry and image quality of turbo-flash and retrospective dual-source CT coronary angiography. Radiol Med 125:117–127
Lim J, Park EA, Lee W et al (2015) Image quality and radiation reduction of 320-row area detector CT coronary angiography with optimal tube voltage selection and an automatic exposure control system: comparison with body mass index-adapted protocol. Int J Cardiovasc Imaging 31:23–30
Richards CE, Obaid DR (2019) Low-dose radiation advances in coronary computed tomography angiography in the diagnosis of coronary artery Disease. Curr Cardiol Rev 15:304–315
Mangold S, Wichmann JL, Schoepf UJ et al (2016) Automated tube voltage selection for radiation dose and contrast medium reduction at coronary CT angiography using 3(rd) generation dual-source CT. Eur Radiol 26:3608–3616
Choi AD, Leifer ES, Yu J et al (2016) Prospective evaluation of the influence of iterative reconstruction on the reproducibility of coronary calcium quantification in reduced radiation dose 320 detector row CT. J Cardiovasc Comput Tomogr 10:359–363
Palumbo P, Cannizzaro E, Bruno F et al (2020) Coronary artery disease (CAD) extension-derived risk stratification for asymptomatic diabetic patients: usefulness of low-dose coronary computed tomography angiography (CCTA) in detecting high-risk profile patients. Radiol Med [Online ahead of print]
Naoum C, Blanke P, Leipsic J (2015) Iterative reconstruction in cardiac CT. J Cardiovasc Comput Tomogr 9:255–263
Choi AD, Leifer ES, Yu JH et al (2019) Reduced radiation dose with model based iterative reconstruction coronary artery calcium scoring. Eur J Radiol 111:1–5
Jin L, Gao Y, Jiang A et al (2020) Can the coronary artery calcium score scan reduce the radiation dose in coronary computed tomography angiography? Acad Radiol [Online ahead of print]
Andreini D, Mushtaq S, Conte E et al (2016) Coronary CT angiography with 80 kV tube voltage and low iodine concentration contrast agent in patients with low body weight. J Cardiovasc Comput Tomogr 10:322–326
Cademartiri F, Garot J, Tendera M et al (2015) Intravenous ivabradine for control of heart rate during coronary CT angiography: a randomized, double-blind, placebo-controlled trial. J Cardiovasc Comput Tomogr 9:286–294
Hoffmann U, Ferencik M, Udelson JE et al (2017) PROMISE investigators. prognostic value of noninvasive cardiovascular testing in patients with stable chest pain: insights from the PROMISE trial (Prospective multicenter imaging study for evaluation of chest pain). Circulation 135:2320–2332
Williams MC, Newby DE (2016) CT myocardial perfusion imaging: current status and future directions. Clin Radiol 71:739–749
Caruso D, Eid M, Schoepf U et al (2016) Dynamic CT myocardial perfusion imaging. Eur Radiol 85:1893–1899
Bischoff B, Deseive S, Rampp M et al (2017) Myocardial ischemia detection with single-phase CT perfusion in symptomatic patients using high-pitch helical image acquisition technique. Int J Cardiovasc Imaging 33:569–576
Keulards DCJ, Fournier S, van ‘t Veer M et al (2020) Computed tomographic myocardial mass compared with invasive myocardial perfusion measurement. Heart [Online ahead of print]
Tabari A, Lo Gullo R, Murugan V et al (2017) Recent advances in computed tomographic technology: cardiopulmonary imaging applications. J Thorac Imaging 32:89–100
Nazir MS, Mittal TK, Weir-McCall J et al (2020) Opportunities and challenges of implementing computed tomography fractional flow reserve into clinical practice. Heart [Online ahead of print]
De Santis D, Eid M, De Cecco C et al (2018) Dual-energy computed tomography in cardiothoracic vascular imaging. Radiol Clin North Am 56:521–534
van Assen M, Vonder M, Pelgrim GJ (2020) Computed tomography for myocardial characterization in ischemic heart disease: a state-of-the-art review. Eur Radiol Exp 4:36
Cicero G, Ascenti G, Albrecht MH et al (2020) Extra-abdominal dual-energy CT applications: a comprehensive overview. Radiol Med 125:384–397
van den Oever LB, Vonder M, van Assen M et al (2020) Application of artificial intelligence in cardiac CT: from basics to clinical practice. Eur J Radiol 128:108969
Lell M, Marc Kachelrieß M (2020) Recent and upcoming technological developments in computed tomography: high speed, low dose, deep learning, multienergy. Invest Radiol 55:8–19
Grassi R, Miele V, Giovagnoni A (2019) Artificial intelligence: a challenge for third millennium radiologist. Radiol Med 124:241–242
Kosmala A, Petritsch B, Weng A et al (2019) Radiation dose of coronary CT angiography with a third-generation dual-source CT in a “real-world” patient population. Eur Radiol 29:4341–4348
Schicchi N, Fogante M, Giuseppetti GM et al (2019) Diagnostic detection with cardiac tomography and resonance of extremely rare coronary anomaly: a case report and review of literature. World J Clin Cases 7:628–635
Pan Y, Zhou S, Wang Y et al (2020) Application of low tube voltage, low-concentration contrast agent using a 320-row CT in coronary CT angiography: evaluation of image quality, radiation dose and iodine intake. Curr Med Sci 40:178–183
Agliata G, Schicchi N, Agostini A et al (2019) Radiation exposure related to cardiovascular CT examination: comparison between conventional 64-MDCT and third-generation dual-source MDCT. Radiol Med 124:753–761
Zhang L, Wang Y, Schoepf U et al (2016) Image quality, radiation dose, and diagnostic accuracy of prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp in a clinical setting: comparison with invasive coronary angiography. Eur Radiol 26:797–806
McGraw S, Carlson C, Grant K et al (2018) Feasibility of ultra low-dose coronary computed tomography angiography. Indian Heart J 70:443–445
Ippolito D, Riva L, Talei Franzesi CR et al (2019) Diagnostic efficacy of model-based iterative reconstruction algorithm in an assessment of coronary artery in comparison with standard hybrid-Iterative reconstruction algorithm: dose reduction and image quality. Radiol Med 124:350–359
Smettei O, Sayed S, Al Habib A et al (2018) Ultra-fast, low dose high-pitch (FLASH) versus prospectively-gated coronary computed tomography angiography: comparison of image quality and patient radiation exposure. J Saudi Heart Assoc 30:165–171
Ochs MM, Andre F, Korosoglou G et al (2017) Strengths and limitations of coronary angiography with turbo high-pitch third-generation dual-source CT. Clin Radiol 72:739–744
De Marco E, Vacchiano G, Frati P et al (2018) Evolution of post-mortem coronary imaging: from selective coronary arteriography to post-mortem CT-angiography and beyond. Radiol Med 123:351–358
Koplay M, Erdogan H, Avci A et al (2016) Radiation dose and diagnostic accuracy of high-pitch dual-source coronary angiography in the evaluation of coronary artery stenoses. Diagn Interv Imaging 97:461–469
Wang W, Zhao Y, Qi L et al (2017) Prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp with 30 mL contrast agent: an intraindividual comparison with sequential scanning at 120 kVp With 60 mL contrast agent. Eur J Radiol 90:97–105
Schicchi N, Fogante M, Pirani PE et al (2020) Third generation dual source CT with ultra-high pitch protocol for TAVI planning and coronary tree assessment: feasibility, image quality and diagnostic performance. Eur J Radiol 122:108749
Vonder M, Vliegenthart R, Kaatee M et al (2018) High-pitch versus sequential mode for coronary calcium in individuals with a high heart rate: potential for dose reduction. J Cardiovasc Comput Tomogr 12:298–304
Latif MA, Sanchez FW, Sayegh K et al (2016) Volumetric single-beat coronary computed tomography angiography: relationship of image quality, heart rate, and body mass index. Initial patient experience with a new computed tomography scanner. J Comput Assist Tomogr 40:763–772
Di Cesare E, Patriarca L, Panebianco L et al (2018) Coronary computed tomography angiography in the evaluation of intermediate risk asymptomatic individuals. Radiol Med 123:686–694
Carpeggiani C, Picano E, Brambilla M et al (2017) Variability of radiation doses of cardiac diagnostic imaging tests: the RADIO-EVINCI study (RADIationdOse Subproject of the EVINCI Study). BMC Cardiovasc Disord 17:63
Funding
This research did not receive any specific grant from funding agencies in the public, commercial or not-for-profit sectors.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflicts of interest
The authors declare no potential conflicts of interests associated with this study.
Research involving human participants and/or animals
All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.
Informed consent
Informed consent was obtained from all individual participants included in the study.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Schicchi, N., Fogante, M., Palumbo, P. et al. The sub-millisievert era in CTCA: the technical basis of the new radiation dose approach. Radiol med 125, 1024–1039 (2020). https://doi.org/10.1007/s11547-020-01280-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11547-020-01280-1