Skip to main content
Log in

Characterizing the radiation response of Cherenkov glass detectors with isotopic sources

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

Cherenkov detectors are widely used for particle identification and threshold detectors in high-energy physics. Glass Cherenkov detectors that are sensitive to beta emissions originating from neutron activation have been demonstrated recently as a potential replacement for activation foils. In this work, we set the groundwork to evaluate large Cherenkov glass detectors for sensitivity to MeV photons through first understanding the measured response of small Cherenkov glass detectors to isotopic gamma-ray sources. Counting and pulse height measurements are acquired with reflected glass Cherenkov detectors read out with a photomultiplier tube. Simulation was used to inform our understanding of the measured results. This simulation included radioactive source decay, radiation interaction, Cherenkov light generation, optical ray tracing, and photoelectron production. Implications for the use of Cherenkov glass detectors to measure low energy gamma-ray response are discussed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. Cherenkov PA (1934) Visible light from clear liquids under the action of gamma radiation. Dokl Akad Nauk SSSR 2:451

    CAS  Google Scholar 

  2. Vavilov SI (1934) On possible causes of dark blue radiation in liquids. Dokl Akad Nauk SSSR 2:457

    CAS  Google Scholar 

  3. Carlson P (ed) (1986) Cherenkov detectors and their applications in science and technology. Nucl. Instrum. Methods A 248

  4. Iijima I et al (2008) Studies of a proximity focusing aerogel RICH for future Belle upgrade. Nucl. Inst. Meth. A 595:92–95

    Article  CAS  Google Scholar 

  5. Krizan P (2009) Recent progress in particle identification methods. Nucl. Inst. Meth. A 598:130–137

    Article  CAS  Google Scholar 

  6. Lecoq P, Auffray E, Brunner S, Hillemans H, Jarron P, Knapitsch A, Meyer T, Polowny F (2010) Factors influencing the time resolution of scintillators and ways to improve them. IEEE Trans Nucl Sci 57:2411–2416

    Article  CAS  Google Scholar 

  7. Korpar S et al (2011) Study of TOF PET using Cherenkov light. Nucl. Instrum. Methods A 654:532–538. doi:10.1016/j.nima.2011.06.035

    Article  CAS  Google Scholar 

  8. Li S, Wang Y, Kang K, Li Y, Li Y (2010) X-Ray inspection system based on Cherenkov detector. IEEE NSS Conference Record, N03-5

  9. Bell ZW, Boatner LA (2010) Neutron detection via the Cherenkov effect. IEEE Trans. Nucl. Sci. 57:3800

    Article  CAS  Google Scholar 

  10. Bell ZW, Boatner LA (2009) US Patent 7,601,965, Infra-red signature neutron detector, issued October 13, 2009

  11. Bell ZW, Boatner LA (2009) US Patent 7,629,588, Activation Detector, issued December 8, 2009

  12. Bell ZW, Boatner LA (2011) US Patent 7,952,075, Neutron Absorption Detector, issued May 31, 2011

  13. http://geant4.cern.ch/G4UsersDocuments/UsersGuides/PhysicsReferenceManual/html/node37.html. Accessed June 2011

  14. Sowerby BD (1971) Cerenkov detectors for low energy gamma rays. Nucl. Instrum. Methods 97:145–149

    Article  CAS  Google Scholar 

  15. http://www.nist.gov/pml/data/xcom/index.cfm. Accessed June 2011

  16. Allison SW, Boatner LA, Sales SC (1998) Very high numerical aperture light transmitting device, US Patent 5,812,729, issued September 22, 1998

  17. Photomultiplier Tubes: basics and applications, 3rd edn, Hamamatsu Photonics, Hamamatsu City, Japan, 1999

  18. Knoll GF (2010) Radiation detection and measurement, 4th edn, Wiley, New York, p 291

  19. Johnson FA (1970) Investigation of source-dependent contributions to photomultiplier noise. Nucl. Instrum Methods 87:200–215

    Google Scholar 

  20. Agostinelli S et al (2003) Geant 4: a simulation toolkit. Nucl. Instrum Methods A 506:250–303

    Article  CAS  Google Scholar 

  21. Hamamatsu R2049 data sheet, p. 2, Available: http://sales.hamamatsu.com/en/products/electron-tube-division/detectors/photomultiplier-tubes/part-r2059.php. Accessed June 2011

  22. Hamamatsu PMT handbook, 3rd edn, Fig. 4–5, p. 37, Available: http://sales.hamamatsu.com/assets/applications/ETD/pmt_handbook_complete.pdf. Accessed June 2011

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to J. P. Hayward.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hayward, J.P., Hobbs, C.L., Bell, Z.W. et al. Characterizing the radiation response of Cherenkov glass detectors with isotopic sources. J Radioanal Nucl Chem 295, 1143–1151 (2013). https://doi.org/10.1007/s10967-012-1898-4

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10967-012-1898-4

Keywords

Navigation