Abstract
Cherenkov detectors are widely used for particle identification and threshold detectors in high-energy physics. Glass Cherenkov detectors that are sensitive to beta emissions originating from neutron activation have been demonstrated recently as a potential replacement for activation foils. In this work, we set the groundwork to evaluate large Cherenkov glass detectors for sensitivity to MeV photons through first understanding the measured response of small Cherenkov glass detectors to isotopic gamma-ray sources. Counting and pulse height measurements are acquired with reflected glass Cherenkov detectors read out with a photomultiplier tube. Simulation was used to inform our understanding of the measured results. This simulation included radioactive source decay, radiation interaction, Cherenkov light generation, optical ray tracing, and photoelectron production. Implications for the use of Cherenkov glass detectors to measure low energy gamma-ray response are discussed.
Similar content being viewed by others
References
Cherenkov PA (1934) Visible light from clear liquids under the action of gamma radiation. Dokl Akad Nauk SSSR 2:451
Vavilov SI (1934) On possible causes of dark blue radiation in liquids. Dokl Akad Nauk SSSR 2:457
Carlson P (ed) (1986) Cherenkov detectors and their applications in science and technology. Nucl. Instrum. Methods A 248
Iijima I et al (2008) Studies of a proximity focusing aerogel RICH for future Belle upgrade. Nucl. Inst. Meth. A 595:92–95
Krizan P (2009) Recent progress in particle identification methods. Nucl. Inst. Meth. A 598:130–137
Lecoq P, Auffray E, Brunner S, Hillemans H, Jarron P, Knapitsch A, Meyer T, Polowny F (2010) Factors influencing the time resolution of scintillators and ways to improve them. IEEE Trans Nucl Sci 57:2411–2416
Korpar S et al (2011) Study of TOF PET using Cherenkov light. Nucl. Instrum. Methods A 654:532–538. doi:10.1016/j.nima.2011.06.035
Li S, Wang Y, Kang K, Li Y, Li Y (2010) X-Ray inspection system based on Cherenkov detector. IEEE NSS Conference Record, N03-5
Bell ZW, Boatner LA (2010) Neutron detection via the Cherenkov effect. IEEE Trans. Nucl. Sci. 57:3800
Bell ZW, Boatner LA (2009) US Patent 7,601,965, Infra-red signature neutron detector, issued October 13, 2009
Bell ZW, Boatner LA (2009) US Patent 7,629,588, Activation Detector, issued December 8, 2009
Bell ZW, Boatner LA (2011) US Patent 7,952,075, Neutron Absorption Detector, issued May 31, 2011
http://geant4.cern.ch/G4UsersDocuments/UsersGuides/PhysicsReferenceManual/html/node37.html. Accessed June 2011
Sowerby BD (1971) Cerenkov detectors for low energy gamma rays. Nucl. Instrum. Methods 97:145–149
http://www.nist.gov/pml/data/xcom/index.cfm. Accessed June 2011
Allison SW, Boatner LA, Sales SC (1998) Very high numerical aperture light transmitting device, US Patent 5,812,729, issued September 22, 1998
Photomultiplier Tubes: basics and applications, 3rd edn, Hamamatsu Photonics, Hamamatsu City, Japan, 1999
Knoll GF (2010) Radiation detection and measurement, 4th edn, Wiley, New York, p 291
Johnson FA (1970) Investigation of source-dependent contributions to photomultiplier noise. Nucl. Instrum Methods 87:200–215
Agostinelli S et al (2003) Geant 4: a simulation toolkit. Nucl. Instrum Methods A 506:250–303
Hamamatsu R2049 data sheet, p. 2, Available: http://sales.hamamatsu.com/en/products/electron-tube-division/detectors/photomultiplier-tubes/part-r2059.php. Accessed June 2011
Hamamatsu PMT handbook, 3rd edn, Fig. 4–5, p. 37, Available: http://sales.hamamatsu.com/assets/applications/ETD/pmt_handbook_complete.pdf. Accessed June 2011
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Hayward, J.P., Hobbs, C.L., Bell, Z.W. et al. Characterizing the radiation response of Cherenkov glass detectors with isotopic sources. J Radioanal Nucl Chem 295, 1143–1151 (2013). https://doi.org/10.1007/s10967-012-1898-4
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10967-012-1898-4