1 Introduction

Hydroxyapatite [Ca10(PO4)6(OH)2, HAP] is a stable apatite compound and has been used widely due to its similarity to human bone composition, biocompatibility and bioactivity [1]. Synthetic HAP is employed as a biomaterial for orthopaedic and dental replacements [2]. Beside medical applications it has been also applied in the field of heterogeneous catalysis as a support because of its bifunctionality, hydrophilic properties and high structural stability, as reviewed by Gruselle et al. [3]. HAP can also be applied in other fields, such as purification of wastewater, detection of heavy metals in water [4, 5], environmental pollution control [6] and electrochemical applications [7]. The most common form of HAP is the hexagonal crystal structure, P63/m space group, with Ca/P ratio 1.67 [8]. The most widely employed method to synthesise HAP is by wet chemical precipitation [9,10,11]. Alternative techniques are sol–gel [12], hydrothermal [13] or other protocols that involve microwave irradiations [14], spray pyrolysis [15] or emulsion processing [16]. A number of factors influence the precipitation of HAP, such as stoichiometry, pH, temperature and rate of reagent addition; it is therefore crucial to control these aspects to produce HAP with an optimum morphology and crystallinity [17].

The stability of HAP affects its solubility, biocompatibility and resorption rate influencing the performance as a bio-implant in living systems [18]. Dehydroxylation of HAP at high temperatures, leading to loss of the OH group, can negatively influence the activity of HAP as a catalyst support [19]. In consequence, several compounds can be formed such as oxyapatite (OAP), oxyhydroxyapatite (OHAP), β-tricalcium phosphate (β-TCP), calcium oxide and tetracalcium phosphate (TTCP) [20, 21]. Dehydroxylation is accelerated by increased deficiency of calcium ions in HAP and occurs at 500 °C, as described by Raynaud et al. [22]. Other studies focused on the mechanical stability of HAP scaffolds for bio-medical applications. For example Gervaso et al. [23]. described the mechanical stability of the previously synthesised scaffolds using compression in simulated body fluid (SBF) and tris–HCl buffer finding that after 28 days the stress at failure was 0.57 MPa, which was only slightly different to samples before soaking, 0.51 MPa [23]. An understanding of the chemical stability of HAP is required for many applications. For example, Sun et. al [21]. reported the influence of pH (during synthesis) on the properties of HAP, showing the formation of octacalcium phosphate (OCP) at low pH, while HAP is present at higher pH and temperatures [21].

We recently reported the successful preparation of mesporous HAP and its application as a heterogeneous catalyst support in the decomposition of methane in natural gas-diesel engine exhaust emissions [24, 25]. Here, we investigate the stability of this mesoporous HAP by testing its resistance to ultrasonic treatment, pH and temperature. The results show that the HAP structure is mechanically robust, fully resistant to changes in pH, and stable upon heating in air to approximately 650 °C. These findings support the use of HAP in a range of applications.

2 Experimental

2.1 Materials and Chemicals

All chemicals: calcium nitrate tetrahydrate (>99%), potassium phosphate monobasic (>99%), nitric acid 70% (v/v), polyoxyethylene(20) sorbitan monostearate (10% in H2O), nonaoxyethylene dodecyl ether, sodium hydroxide pellets (>98%), ethanol (98%), phosphoric acid 85% (v/v), boric acid (99.5%), ethanoic acid >99% (v/v) were obtained from Sigma-Aldrich and used as received without any further purification. All solutions were made using deionised water with resistivity not less than 18.2 MΩ cm.

2.2 Synthesis of Hydroxyapatite

Hydroxyapatite (HAP) synthesis was based on a method reported elsewhere [26]. Ca(NO3)2 (7.88 g) was mixed with KH2PO4 (2.72 g), dissolved in deionised water (26.60 mL) and acidified by concentrated HNO3 (13.60 mL) to avoid precipitation of Ca3(PO4)2. This acidic solution was then added to a mixture of polyoxyethylene(20) sorbitan monostearate (Tween 60, 26 g) and nonaoxyethylene dodecyl ether (C12EO9, 10.66 g), and heated to 60 °C with stirring until a clear solution was formed. The solution was cooled to room temperature and treated with NaOH (0.2 M) added dropwise to maintain a stable pH of 9.8 to precipitate HAP. The suspension was stirred overnight, filtered, washed with ethanol and water, dried at 60 °C in air and calcined in air for 5 h at 550 °C with a heating rate 10 °C min−1.

2.3 Mechanical Testing

HAP (0.1 g) was mixed with deionised water (1 mL) in a volumetric flask. Mixtures were placed in an ultrasonic bath (Ultrawave Limited, Cardiff, UK) for durations from 10 min to 1 h. A sample of HAP was left without any ultrasonic treatment as a control. All samples were recovered by filtration and dried at 60 °C in air.

2.4 pH Stability

HAP (0.3 g) was added to Britton–Robinson buffer solutions (20 mL). Different pH (2, 4, 6, 8, 10, 12) buffers were prepared using NaOH (0.2 M). The mixtures were stirred for 3 h under ambient conditions, the solid was recovered by filtration and dried at 60 °C in air.

2.5 Thermal Stability

HAP (0.3 g) samples were placed in crucibles and heated in a furnace (OMEGALUX LMF-3550) to temperatures between 550 and 900 °C for 3 h in air with a heating rate 10 °C min−1. Each sample was cooled to room temperature prior to removal.

2.6 Characterisation

X-ray diffraction (XRD) was conducted in powder spinning mode at ambient conditions using a Panalytical X’Pert Powder diffractometer with Cu Kα radiation (λ = 1.5406 Å). All powder diffraction patterns were recorded with step size 0.052 and step time 200 s, using an X-ray tube operated at 40 kV and 30 mA with fixed 1/2° anti-scatter slit. Nitrogen adsorption/desorption measurements were carried out using a Micromeritics ASAP 2020 Surface Analyser at −196 °C. Samples were degassed under vacuum (p < 10−5 mbar) for 3 h at 300 °C prior to analysis. Surface areas of the samples were calculated in the relative pressure range 0.05–0.30 using the BET isotherm model; this is the accepted method of reporting surface areas. Microscopic images were recorded using a Supra 40VP (Carl Zeiss Ltd, UK) scanning electron microscope (SEM). Fourier transform infrared spectroscopy (FTIR) was conducted using a diamond source Nicolet 380 series, Thermo Electron Corporation.

3 Results and Discussion

3.1 Mechanical Testing

The SEM images in Fig. 1 clearly show that HAP is stable to 1 h continuous exposure to ultrasonic treatment. The surface areas of treated samples varied by less than ±1% over the full range of ultrasound times used (data not shown). These data agree well with those reported in literature. For example, the mechanical stability of HAP scaffolds, prepared by a sponge replica method, was evaluated by a uniaxial compression test, which calculates the strength of HAP by measuring the stress value at failure. Results showed that the mechanical strength of this HAP was practically unchanged following 28 days’ immersion in simulated body fluid [23]. HAP coatings deposited on titanium substrates were sufficiently strong that scratching with a diamond indenter was required to physically remove part of the HAP [27]. The fact that we do not observe any changes in HAP using the soft-templated preparation method proves that this HAP is particularly stable given the severity of 1 h ultrasonic treatment. Our findings support the use of HAP in applications where such materials’ robustness and resistance to physical degradation are required.

Fig. 1
figure 1

SEM images of ultrasound treated HAP: as-synthesised (a); 20 mins (b); 40 min (c); 60 min (d)

3.2 pH Stability

SEM images, Fig. 2, indicate that there are no detectable morphological changes to the HAP morphology in either acidic or alkaline conditions. The XRD powder patterns, Fig. 3, are identical across the full pH range 2–12, confirming that the hexagonally oriented HAP structure is unaffected by exposure to aqueous buffer solution over the full pH range. FTIR spectra, Fig. 4, identify the fundamental vibrational modes of HAP phosphate groups whereby the most intense peak at 1021 cm−1 and another peak at 1089 cm−1 are assigned to the v3 P–O stretching bond. The band at 962 cm−1 is attributed to the v1 P–O stretching bond and the relatively weak signal at 3568 cm−1 corresponds to the OH group [28]. Taken together with the SEM images and XRD patterns, the FTIR spectra provide further evidence of the stability of HAP to acid/alkaline solution by the presence of identical spectra over the entire pH range. It is well known that the properties of HAP are strongly affected by the pH of solutions used during synthesis. Sun et al. showed that the particle size and morphology of HAP prepared by hydrothermal treatment at 180 °C for 10 h varied as follows: pH 3.0, 3-D structured flower-like morphology; pH 5.0, 2-D nanoribbons diameter approximately 500 nm; pH 7.0, nanorods diameter approximately 20 nm; pH 11.0, nanospheres [21]. Reports in the literature showing how pH affects the structural and morphological characteristics of post-synthesis HAP are lacking but, fortunately, it is possible to infer a comparison by examining the solubility product of HAP treated in acidic/alkaline solution. Larsen et al. showed that the solubility product of enamel apatite varied from 10 to 56.9 after exposure to pH 4.6 for 60 days to 10−52.8 at pH 7.6. While the solubility product increases by a factor of approximately 104, the absolute values of solubility product are extremely low across the pH scale i.e., HAP is practically insoluble. This suggests that any changes to the apatite structure due to dissolution into solution would be negligible, which is confirmed by the identical XRD spectra recorded for all samples from pH 4.6 to 7.6 and the absence of any other calcium phosphate phases [29]. In another study, the solubility product of HAP (Ca:P ratio 1.664) was found to be constant over the pH range 4.56–9.67, although no XRD results were included [30].

Fig. 2
figure 2

SEM images of HAP treated in buffer pH 2 (a) and pH 12 (b)

Fig. 3
figure 3

XRD powder patterns of HAP in pH buffer

Fig. 4
figure 4

FTIR spectra of HAP in pH buffer

It is interesting to note that the surface area of HAP increases in acidic media and decreases in basic media, Table 1. This may be a result of the higher concentrations of OH ions at progressively higher pH. Studies have shown that surface OH ions are required for the crystallisation and growth of Ca5(PO4)3OH [21]. It seems plausible that, in our study, the OH ions remaining from the pH treatment may cause further reaction of the HAP during the heating step that precedes BET surface area analysis, which ultimately causes some agglomeration of particles with an associated reduction in surface area. The extent of this reaction increases with greater pH due to the increasing OH concentration.

Table 1 Nitrogen adsorption porosimetry data of HAP in pH buffer

3.3 Influence of Temperature

Heating in air causes the transformation of rod like crystals, with well-defined edges, of the as synthesised HAP to larger agglomerated spherical particles; this effect is first detected at 700 °C and becomes increasingly more pronounced at higher temperatures, SEM images Fig. 5. This sintering of particles and the associated increase in particle size, and decrease in surface area Table 2, are typical of Ostwald ripening. Sun et al. showed that the particle size and shape of HAP were unchanged after heating to 600 °C but the HAP building units sintered together on heating at 800 °C [21]. In another study, heat treatment of HAP coatings to 700 °C in dry air caused the edges of the crystals to become more rounded, while heating to 900 °C in the same conditions resulted in crystals being fully covered with smaller crystal grains [20] The crystallinity was examined by XRD. As shown in Fig. 6, the diffraction peaks become more intense with temperature, implying an improvement in HAP crystallinity (see XRD pattern of untreated HAP, ESI Fig. 1, as a comparison). While the HAP crystal structure is present over the entire temperature range, there is partial transformation/decomposition of the HAP phase that becomes more pronounced with increased temperature. HAP is known to undergo dehydroxylation to oxyhydroxyapatite (OHAP), and to transform into several calcium phosphates, such as TTCP or β-TCP, as described by Rapacz-Kmita et al. [18]. In the present study, HAP dehydroxylation starts at 650 °C with further decomposition to β-TCP from 750 °C. The dehydroxylation and decomposition reactions of HAP can be distinguished using FTIR. As observed in Fig. 7 (right), the P-O vibration band at 1082 cm−1 becomes broader as the temperature increases, suggesting the transformation of HAP to β-TCP [28]. According to the report by Savino et al., [20] where HAP was electrochemically functionalised with fluoride to increase thermal resistance of the material, unmodified HAP decomposed to β-TCP at 600 °C, which is lower than that reported in this manuscript. The weak O-H band at 3567 cm−1 disappears due to the dehydroxylation process and subsequent formation of OHAP (Fig. 6 left). It is noteworthy that there are two small vibration bands at 1455 and 1412 cm−1 that correspond to v3 CO3 2− adsorbed from the air onto the surface of HAP, diminishing at higher temperatures showing that the carbonate ion is released [31, 32].

Fig. 5
figure 5

SEM images as a function of treatment temperature; as synthesised HAP (a); 700 °C (b); 750 °C (c); 800 °C (d); 850 °C (e); 900 °C (f)

Table 2 Nitrogen adsorption porosimetry data of HAP as a function of treatment temperature
Fig. 6
figure 6

XRD powder patterns of HAP as a function of treatment temperature: filled square HAP; filled inverted triangle OHAP; filled circle β-TCP. (Color figure online)

Fig. 7
figure 7

FTIR spectra of HAP as a function of treatment temperature

4 Conclusions

Mesoporous HAP was successfully synthesised by a mixed surfactant, soft-templated approach. Studies proved that the crystal structure and morphology of mesoporous HAP are unaffected by ultrasonic treatment or exposure to pH in the range 2–12. HAP was stable to heating in air to approximately 650 °C, while higher temperatures caused partial decomposition of the HAP structure, reduced surface area and increased particle size.