Abstract
In this study, we aimed to continuously measure cardiac output (CO) with the electrical velocimetry (EV) method and characterize the hemodynamic profile of patients undergoing spinal anesthesia for elective cesarean delivery (CD), and to discuss the potential benefit of using real time CO monitoring to guide patient management. Forty-two patients scheduled for elective CD under spinal anesthesia were enrolled in this observational study. A non-invasive CO monitor incorporating the electrical velocimetry algorithm, ICON® (Cardiotronic®, La Jolla, California, USA), was used to measure CO and stroke volume (SV) continuously. Peripheral venous pressure was measured intermittently at pre-defined time points. Systemic vascular resistance was calculated retrospectively after completion of the study. Hemodynamic changes at pre-defined time points and caused by phenylephrine administration were analyzed. Hypotension (MAP reduction more than 20 % from baseline values) occurred in 71.1 % of patients after spinal anesthesia, while the coinstantaneous CO was increased ≥20 % from baseline in the majority of patients (76.3 %) at the same time. Significant increase in CO took place at 3–2 min before the administration of phenylephrine bolus. Treatment of hypotension with phenylephrine was associated with significant decrease in CO. Continuous CO monitoring with EV enables clinicians to determine CO and SV changes prior to onset of hypotension and to better understand patients’ hemodynamics. It is an important addition to the current monitoring. The benefit of routinely using this technique remains to be determined in term of the patient outcomes.
Similar content being viewed by others
References
Menacker F, Hamilton BE. Recent trends in cesarean delivery in the United States. NCHS Data Brief. 2010;35:1–8.
Habib AS. A review of the impact of phenylephrine administration on maternal hemodynamics and maternal and neonatal outcomes in women undergoing cesarean delivery under spinal anesthesia. Anesth Analg. 2012;114:377–90.
Borgeat A, Ekatodramis G, Schenker CA. Postoperative nausea and vomiting in regional anesthesia: a review. Anesthesiology. 2003;98:530–47.
Dyer RA, Reed AR, van Dyk D, Arcache MJ, Hodges O, Lombard CJ, Greenwood J, James MF. Hemodynamic effects of ephedrine, phenylephrine, and the coadministration of phenylephrine with oxytocin during spinal anesthesia for elective cesarean delivery. Anesthesiology. 2009;111:753–65.
Langesaeter E, Dyer RA. Maternal haemodynamic changes during spinal anaesthesia for caesarean section. Curr Opin Anaesthesiol. 2011;24:242–8.
Peyton PJ, Chong SW. Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision. Anesthesiology. 2010;113:1220–35.
Schmidt C, Theilmeier G, Van Aken H, Korsmeier P, Wirtz SP, Berendes E, Hoffmeier A, Meissner A. Comparison of electrical velocimetry and transoesophageal Doppler echocardiography for measuring stroke volume and cardiac output. Br J Anaesth. 2005;95:603–10.
Mekis D, Kamenik M, Starc V, Jeretin S. Cardiac output measurements with electrical velocimetry in patients undergoing CABG surgery: a comparison with intermittent thermodilution. Eur J Anaesthesiol. 2008;25:237–42.
Norozi K, Beck C, Osthaus WA, Wille I, Wessel A, Bertram H. Electrical velocimetry for measuring cardiac output in children with congenital heart disease. Br J Anaesth. 2008;100:88–94.
Raue W, Swierzy M, Koplin G, Schwenk W. Comparison of electrical velocimetry and transthoracic thermodilution technique for cardiac output assessment in critically ill patients. Eur J Anaesthesiol. 2009;26:1067–71.
Zoremba N, Bickenbach J, Krauss B, Rossaint R, Kuhlen R, Schalte G. Comparison of electrical velocimetry and thermodilution techniques for the measurement of cardiac output. Acta Anaesthesiol Scand. 2007;51:1314–9.
Osthaus WA, Huber D, Beck C, Winterhalter M, Boethig D, Wessel A, Sumpelmann R. Comparison of electrical velocimetry and transpulmonary thermodilution for measuring cardiac output in piglets. Paediatr Anaesth. 2007;17:749–55.
Bernstein DP, Lemmens HJ. Stroke volume equation for impedance cardiography. Med Biol Eng Comput. 2005;43:443–50.
Bernstein DP, Osypka MJ (2003) Apparatus and method for determining an approximation of the stroke volume and the cardiac output of the heart. United States Patent 6511438.
Archer TL, Conrad BE, Suresh P, Tarsa M. Electrical velocimetry demonstrates the increase in cardiac output and decrease in systemic vascular resistance accompanying cesarean delivery and oxytocin administration. J Clin Anesth. 2012;24:79–82.
Archer TL. Electrical velocimetry elucidates the hemodynamics of hypertension caused by indigo carmine. J Clin Anesth. 2011;23:166–8.
Archer TL, Suresh P, Shapiro AE. Cardiac output measurement, by means of electrical velocimetry, may be able to determine optimum maternal position during gestation, labour and caesarean delivery, by preventing vena caval compression and maximising cardiac output and placental perfusion pressure. Anaesth Intensive Care. 2011;39:308–11.
Kim SH, Park SY, Cui J, Lee JH, Cho SH, Chae WS, Jin HC, Hwang KH. Peripheral venous pressure as an alternative to central venous pressure in patients undergoing laparoscopic colorectal surgery. Br J Anaesth. 2011;106:305–11.
Tugrul M, Camci E, Pembeci K, Al-Darsani A, Telci L. Relationship between peripheral and central venous pressures in different patient positions, catheter sizes, and insertion sites. J Cardiothorac Vasc Anesth. 2004;18:446–50.
Nielsen PE, Erickson JR, Abouleish EI, Perriatt S, Sheppard C. Fetal heart rate changes after intrathecal sufentanil or epidural bupivacaine for labor analgesia: incidence and clinical significance. Anesth Analg. 1996;83:742–6.
Yu ZY, Lumbers ER. Measurement of baroreceptor-mediated effects on heart rate variability in fetal sheep. Pediatr Res. 2000;47:233–9.
Langesaeter E, Rosseland LA, Stubhaug A. Continuous invasive blood pressure and cardiac output monitoring during cesarean delivery: a randomized, double-blind comparison of low-dose versus high-dose spinal anesthesia with intravenous phenylephrine or placebo infusion. Anesthesiology. 2008;109:856–63.
Tihtonen K, Koobi T, Yli-Hankala A, Uotila J. Maternal hemodynamics during cesarean delivery assessed by whole-body impedance cardiography. Acta Obstet Gynecol Scand. 2005;84:355–61.
Stewart A, Fernando R, McDonald S, Hignett R, Jones T, Columb M. The dose-dependent effects of phenylephrine for elective cesarean delivery under spinal anesthesia. Anesth Analg. 2010;111:1230–7.
Landzberg JS, Parker JD, Gauthier DF, Colucci WS. Effects of myocardial alpha 1-adrenergic receptor stimulation and blockade on contractility in humans. Circulation. 1991;84:1608–14.
Dyer RA, Reed AR. Spinal hypotension during elective cesarean delivery: closer to a solution. Anesth Analg. 2010;111:1093–5.
Magder S. Phenylephrine and tangible bias. Anesth Analg. 2011;113:211–3.
Thiele RH, Nemergut EC, Lynch C 3rd. The physiologic implications of isolated alpha (1) adrenergic stimulation. Anesth Analg. 2011;113:284–96.
Brown BR Jr. Selective venoconstriction by dopamine in comparision with isoproterenol and phenylephrine. Anesthesiology. 1975;43:570–2.
Cannesson M, Jian Z, Chen G, Vu TQ, Hatib F. Effects of phenylephrine on cardiac output and venous return depend on the position of the heart on the Frank-Starling relationship. J Appl Physiol. 1985;113:281–9.
Acknowledgments
Authors sincerely thank Dr. Donald P. Bernstein, Cardiovascular Engineering Sotera Wireless, Inc. San Diego, CA for his editing of this article. This project is funded by the Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital.
Conflict of interest
The ICON® monitor was provided by Cardiotronic-Osypka Medical.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Liu, Y., Pian-Smith, M.C.M., Leffert, L.R. et al. Continuous measurement of cardiac output with the electrical velocimetry method in patients under spinal anesthesia for cesarean delivery. J Clin Monit Comput 29, 627–634 (2015). https://doi.org/10.1007/s10877-014-9645-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10877-014-9645-8