Corrosion testing of sintered samples made of the Co-Cr-Mo alloy for surgical applications

  • Published:
Journal of Materials Science: Materials in Medicine Aims and scope Submit manuscript

Abstract

Corrosion resistance of high quality sintered compacts made of the Co-Cr-Mo alloy powder in manufacturing bone implants has been investigated. The samples met the characteristic mechanical requirements for this kind of implants, but the increased density of the porous material turned out to be crucial in the improvement of their corrosion resistance. It seems that the rotary cold repressing (RCR) of sintered compacts could be a very advantageous alternative to the single or multiple matrix pressing. The influence of cold repressing and the subsequent heat treatment of sintered compacts made of the Co-Cr-Mo powder on the changes of their density, microstructure, and corrosion resistance was investigated in this work. © 2005 Springer Science + Business Media, Inc.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. S. STEINEMANN, “Corrosion of Implant Alloys. Technical Principles, Design and Safety of Joint Implants” (Hogrefe & Huber Publ., Seattle-Toronto-Bern-Göttingen, 1990).

    Google Scholar 

  2. E. CLARKE and J. HICKMAN, J. Bone Jt. Surg. 35A (1983).

  3. B. S. BECKER and J. D. BOLTON, Powder Met. 4 (1995) 305.

    Google Scholar 

  4. B. S. BECKER and J. D. BOLTON, The Fifth World Biomaterials Congress, Toronto, Canada (1996) p. 475.

  5. K. H. W. SEAH, R. THAMPURAN and S. H. TEOH, Corr. Sci. 40(4/5) (1998) 547.

    Google Scholar 

  6. J. R. DABROWSKI, J. FRYDRYCH, H. FRYDRYCH and W. RATUSZEK, Arch. Metall. 46(1) (2001) 81.

    Google Scholar 

  7. ASTM G3–87, Standard Reference Test Method for Making Potentiostatic and Potentiodynamic Anodic Polarization Measurements.

  8. ASTM G 59–91, Standard Practice for Conducting Potentiodynamic Polarization Resistance Measurements.

  9. ASTM G 61–86, Standard Test Method for Conducting Cyclic and Potentiodynamic Polarization Measurements for Localized Corrosion Susceptibility of Iron-, Nickel-, or Cobalt-Based Alloys.

  10. Z. OKSIUTA and J. R. DABROWSKI, Powder Metall. 45(1) (2002) 63.

    Google Scholar 

  11. L. WOJNAR, J. R. DABROWSKI and Z. OKSIUTA, Mater. Character. 46 (2001) 221.

    Google Scholar 

  12. K. J. BUNDY, Biomed. Engng. 22 (1994) 139.

    Google Scholar 

  13. A. W. E. HODGSON, S. KURZ, S. VIRTANEN, V. FERVEL, C.-O. A. OLSSON and S. MISCHLER, Electrochimica Acta 49 (2004) 2167.

    Google Scholar 

  14. V. CIHAL, Intergranular Corrosion of Steels and Alloys, Elsevier, 1984.

  15. N. A. HAMPSON and A. J. McNEIL, The Electrochemistry of Porous Electrodes, in Electrochemistry, edited by D. Pletcher, (A Specialist Periodical Report, Royal Soc. Chem., London, 1983) Vol. 8.

  16. D. C. SILVERMAN and J. C. CARRICO, Corrosion - NACE 5 (1988) 280.

    Google Scholar 

  17. E. KRASICKA-CYDZIK and J MSTOWSKI, Bull. Acad. Mining and Metall. Cracow, Metall. Foundry Engng. 23 (1997) 245.

    Google Scholar 

  18. E. KRASICKA-CYDZIK, Biomater. Engng. (Inżynieria Biomateriałow) 7 (1999) 42.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Krasicka-Cydzik, E., Oksiuta, Z. & Dabrowski, J.R. Corrosion testing of sintered samples made of the Co-Cr-Mo alloy for surgical applications. J Mater Sci: Mater Med 16, 197–202 (2005). https://doi.org/10.1007/s10856-005-6680-5

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10856-005-6680-5

Keywords

Navigation