Skip to main content

Advertisement

Log in

Clinical use of multifocal visual-evoked potentials in a glaucoma practice: a prospective study

  • Original Research Article
  • Published:
Documenta Ophthalmologica Aims and scope Submit manuscript

Abstract

Purpose To test a framework that describes how the multifocal visual-evoked potential (mfVEP) technique is used in a particular glaucoma practice. Methods In this prospective, descriptive study, glaucoma suspects, ocular hypertensives and glaucoma patients were referred for mfVEP testing by a single glaucoma specialist over a 2-year period. All patients underwent standard automated perimetry (SAP) and mfVEP testing within 3 months. Two hundred and ten patients (420 eyes) were referred for mfVEP testing for the following reasons: (1) normal SAP tests suspected of early functional loss (ocular hypertensives, n = 43; and glaucoma suspects on the basis of suspicious optic disks, n = 52); (2) normal-tension glaucoma patients with suspected central SAP defects (n = 33); and (3) SAP abnormalities needing confirmation (n = 82). Results All the glaucoma suspects with normal SAP and mfVEP results remained untreated. Of those with abnormal mfVEP results, 68 % (15/22) were treated because the abnormal regions on the mfVEP were consistent with the abnormal regions seen during clinical examination of the optic disk. The mfVEP was abnormal in 86 % (69/80) of eyes with glaucomatous optic neuropathy and SAP damage, even though it did not result in an altered treatment regimen. In NTG patients, the mfVEP showed central defects in 44 % (12 of 27) of the eyes with apparently normal central fields and confirmed central scotomata in 92 % (36 of 39), leading to more rigorous surveillance of these patients. Conclusions In a clinical practice, the mfVEP was used when clinical examination and subjective visual fields provided insufficient or conflicting information. This information influenced clinical management.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. Shah NN, Bowd C, Medeiros FA, Weinreb RN, Sample PA, Hoffmann EM, Zangwill LM (2006) Combining structural and functional testing for detection of glaucoma. Ophthalmology 113:1593–1602

    Article  PubMed  Google Scholar 

  2. Nouri-Mahdavi K, Hoffman D, Tannenbaum DP, Law SK, Caprioli J (2004) Identifying early glaucoma with optical coherence tomography. Am J Ophthalmol 137:228–235

    Article  PubMed  Google Scholar 

  3. Reus NJ, Lemij HJ (2004) The relationship between standard automated perimetry and GDx VCC measurements. Invest Ophthalmol Vis Sci 45:840–845

    Article  PubMed  Google Scholar 

  4. Reus NJ, Lemij HJ (2005) Relationships between standard automated perimetry, HRT confocal scanning laser ophthalmoscopy, and GDx VCC scanning laser polarimetry. Invest Ophthalmol Vis Sci 46:4182–4188

    Article  PubMed  Google Scholar 

  5. Bowd C, Zangwill LM, Medeiros FA, Tavares IM, Hoffmann EM, Bourne RR, Sample PA, Weinreb RN (2006) Structure-function relationships using confocal scanning laser ophthalmoscopy, optical coherence tomography, and scanning laser polarimetry. Invest Ophthalmol Vis Sci 47:2889–2895

    Article  PubMed  Google Scholar 

  6. Sit AJ, Medeiros FA, Weinreb RN (2004) Short-wavelength automated perimetry can predict glaucomatous standard visual field loss by ten years. Semin Ophthalmol 19:122–124

    Article  PubMed  Google Scholar 

  7. Boden C, Pascual J, Medeiros FA, Aihara M, Weinreb RN, Sample PA (2005) Relationship of SITA and full-threshold standard perimetry to frequency-doubling technology perimetry in glaucoma. Invest Ophthalmol Vis Sci 46:2433–2439

    Article  PubMed  Google Scholar 

  8. Baseler HA, Sutter EE, Klein SA, Carney T (1994) The topography of visual evoked response properties across the visual field. Electroenceph Clin Neurophysiol 90:65–81

    Article  PubMed  CAS  Google Scholar 

  9. Klistorner AI, Graham SL, Grigg JR, Billson FA (1998) Multifocal topographic visual evoked potential: improving objective detection of local visual field defects. Invest Ophthalmol Vis Sci 39:937–950

    PubMed  CAS  Google Scholar 

  10. Klistorner A, Graham SL (2000) Objective perimetry in glaucoma. Ophthalmology 107:2283–2299

    Article  PubMed  CAS  Google Scholar 

  11. Graham SL, Klistorner A, Grigg JR, Billson FA (1999) Objective perimetry in glaucoma: recent advances with multifocal stimuli. Surv Ophthalmol 43:199–209

    Article  Google Scholar 

  12. Hood DC, Zhang X, Greenstein VC, Kangovi S, Odel JG, Liebmann JM, Ritch R (2000) An interocular comparison of the multifocal VEP: a possible technique for detecting local damage to the optic nerve. Invest Ophthalmol Vis Sci 41:1580–1587

    PubMed  CAS  Google Scholar 

  13. Hood DC, Zhang X, Winn BJ (2003) Detecting glaucomatous damage with multifocal visual evoked potentials: how can a monocular test work? J Glaucoma 12:3–15

    Article  PubMed  Google Scholar 

  14. Goldberg I, Graham SL, Klistorner AI (2002) Multifocal objective perimetry in the detection of glaucomatous field loss. Am J Ophthalmol 133:29–39

    Article  PubMed  Google Scholar 

  15. Hood DC, Greenstein VC (2003) Multifocal VEP and ganglion cell damage: applications and limitations for the study of glaucoma. Prog Retin Eye Res 22:201–251

    Article  PubMed  Google Scholar 

  16. Hood DC, Thienprasiddhi P, Greenstein VC, Winn BJ, Ohri N, Liebmann JM, Ritch R (2004) Detecting early to mild glaucomatous damage: a comparison of the multifocal VEP and automated perimetry. Invest Ophthalmol Vis Sci 45:492–498

    Article  PubMed  Google Scholar 

  17. Fortune B, Demirel S, Zhang X, Hood DC, Patterson E, Jamil A, Mansberger SL, Cioffi GA, Johnson CA (2007) Comparing multifocal VEP and standard automated perimetry in high-risk ocular hypertension and early glaucoma. Invest Ophthalmol Vis Sci 48:1173–1180

    Article  PubMed  Google Scholar 

  18. Thienprasiddhi P, Greenstein VC, Chu DH, Xu L, Liebmann JM, Ritch R, Hood DC (2006) Detecting early functional damage in glaucoma suspect and ocular hypertensive patients with the multifocal VEP technique. J Glaucoma 15:321–327

    Article  PubMed  Google Scholar 

  19. Hood DC, Ritch R (2009) Use of the multifocal visual evoked potential in glaucoma. In: Giaconi JA, Law SK, Coleman AL, Caprioli J (eds) Pearls of glaucoma management. Springer, Germany, pp 175–180

    Google Scholar 

  20. Hood DC, Harizman N, Kanadani FN, Grippo TM, Baharestani S, Greenstein VC, Liebmann JM, Ritch R (2007) Retinal nerve fibre thickness measured with optical coherence tomography accurately detects confirmed glaucomatous damage. Br J Ophthalmol 91:905–907

    Article  PubMed  CAS  Google Scholar 

  21. Graham SL, Klistorner AI, Goldberg I (2005) Clinical application of objective perimetry using multifocal visual evoked potentials in glaucoma practice. Arch Ophthalmol 123:729–739

    Article  PubMed  Google Scholar 

  22. Thienprasiddhi P, Greenstein VC, Chen CS, Liebmann JM, Ritch R, Hood DC (2003) Multifocal visual evoked potential responses in glaucoma patients with unilateral hemifield defects. Am J Ophthalmol 136:34–40

    Article  PubMed  Google Scholar 

  23. Caprioli J, Sears M, Spaeth GL (1986) Comparison of visual field defects in normal-tension glaucoma and high-tension glaucoma. Am J Ophthalmol 102:402–404

    PubMed  CAS  Google Scholar 

  24. Thonginnetra O, Greenstein VC, Chu D, Liebmann JM, Ritch R, Hood DC (2010) Normal versus high tension glaucoma: a comparison of functional and structural deficits. J Glaucoma 19:151–157

    Article  PubMed  Google Scholar 

Download references

Acknowledgments

This study was supported in part by grants EY09076 and EY02115 from the National Institutes of Health, Bethesda, MD; the Kwie Ding and Mae Sun Wang Research Fund of the New York Glaucoma Research Institute, New York, NY; and the Edith C. Blum Foundation, New York, NY (CGDM).

Conflict of interest

None.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Carlos Gustavo De Moraes.

Rights and permissions

Reprints and permissions

About this article

Cite this article

De Moraes, C.G., Liebmann, J.M., Ritch, R. et al. Clinical use of multifocal visual-evoked potentials in a glaucoma practice: a prospective study. Doc Ophthalmol 125, 1–9 (2012). https://doi.org/10.1007/s10633-012-9324-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10633-012-9324-3

Keywords

Navigation