Repeatability of central corneal thickness measurements of donor corneas in preservation chamber using Fourier-domain anterior segment optical coherence tomography

  • Published:
Cell and Tissue Banking Aims and scope Submit manuscript

Abstract

To evaluate the repeatability of central corneal thickness (CCT) measurements in donor corneas using optical coherence tomography (OCT, RTVue—Optovue, Inc., Fremont, CA). Consecutive corneas were measured by a single observer using the RTVue. All corneas were preserved in the Transend chamber and Life4 °C media (Numedis, Inc., Isanti, MN/USA) and stored at 4 °C. The repeatability was evaluated using a pooled within-subject standard deviation (SD), coefficient of variation (CoV), and intraclass correlation coefficient (ICC). To investigate inter-observer repeatability, a second observer independently measured the CCT for each image scan. CCT was measured in 32 eyes from 18 donors. Measurements were independently repeated by a second observer. The corneas had a mean CCT of 490.99 μm ± 65.95 (381–642) as measured by Observer 1. For observer 1, the SD value for the CCT was 2.94 μm, the CoV value was 0.597%, and the ICC value was 0.998 (95% CI 0.996, 0.999). For observer 2, the SD value was 5.91 μm, the CoV value was 1.21%, and the ICC value was 0.992 (95% CI 0.985, 0.996). The Kappa statistic 21.88% with a p value < 0.001. The Bland–Altman plot shows that the average CCT measurements between the two observers were within 20 μm of each other. The CCT measurements of donor corneas in the preservation chamber using Fourier domain OCT is highly repeatable.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  • Amato D, Lombardo M, Oddone F et al (2011) Evaluation of a new method for the measurement of corneal thickness in eye bank posterior corneal lenticules using anterior segment optical coherence tomography. Br J Ophthalmol 95:580–584

    Article  PubMed  Google Scholar 

  • Janunts E, Langenbucher A, Seitz B (2016) In vitro corneal tomography of donor cornea using anterior segment OCT. Cornea 35:647–653

    Article  PubMed  Google Scholar 

  • Li Y, Tang M, Zhang X et al (2010) Pachymetric mapping with Fourier-domain optical coherence tomography. J Cataract Refract Surg 36:826–831

    Article  PubMed  PubMed Central  Google Scholar 

  • Neubauer AS, Priglinger SG, Thiel MJ et al (2002) Sterile structural imaging of donor cornea by optical coherence tomography. Cornea 21(5):490–494

    Article  PubMed  Google Scholar 

Download references

Funding

There was no direct funding for this study. Supported in part by an unrestricted institutional grant from Research to Prevent Blindness, New York, NY, USA.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sumitra S. Khandelwal.

Ethics declarations

Conflict of interest

All the authors declare that they have no conflict of interest.

Ethical approval

This article does not contain any studies with human participants or animals performed by any of the authors.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Golla, A., Wang, L., Morris, C. et al. Repeatability of central corneal thickness measurements of donor corneas in preservation chamber using Fourier-domain anterior segment optical coherence tomography. Cell Tissue Bank 19, 717–720 (2018). https://doi.org/10.1007/s10561-018-9724-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10561-018-9724-z

Keywords

Navigation