Abstract
To evaluate the repeatability of central corneal thickness (CCT) measurements in donor corneas using optical coherence tomography (OCT, RTVue—Optovue, Inc., Fremont, CA). Consecutive corneas were measured by a single observer using the RTVue. All corneas were preserved in the Transend chamber and Life4 °C media (Numedis, Inc., Isanti, MN/USA) and stored at 4 °C. The repeatability was evaluated using a pooled within-subject standard deviation (SD), coefficient of variation (CoV), and intraclass correlation coefficient (ICC). To investigate inter-observer repeatability, a second observer independently measured the CCT for each image scan. CCT was measured in 32 eyes from 18 donors. Measurements were independently repeated by a second observer. The corneas had a mean CCT of 490.99 μm ± 65.95 (381–642) as measured by Observer 1. For observer 1, the SD value for the CCT was 2.94 μm, the CoV value was 0.597%, and the ICC value was 0.998 (95% CI 0.996, 0.999). For observer 2, the SD value was 5.91 μm, the CoV value was 1.21%, and the ICC value was 0.992 (95% CI 0.985, 0.996). The Kappa statistic 21.88% with a p value < 0.001. The Bland–Altman plot shows that the average CCT measurements between the two observers were within 20 μm of each other. The CCT measurements of donor corneas in the preservation chamber using Fourier domain OCT is highly repeatable.
Similar content being viewed by others
References
Amato D, Lombardo M, Oddone F et al (2011) Evaluation of a new method for the measurement of corneal thickness in eye bank posterior corneal lenticules using anterior segment optical coherence tomography. Br J Ophthalmol 95:580–584
Janunts E, Langenbucher A, Seitz B (2016) In vitro corneal tomography of donor cornea using anterior segment OCT. Cornea 35:647–653
Li Y, Tang M, Zhang X et al (2010) Pachymetric mapping with Fourier-domain optical coherence tomography. J Cataract Refract Surg 36:826–831
Neubauer AS, Priglinger SG, Thiel MJ et al (2002) Sterile structural imaging of donor cornea by optical coherence tomography. Cornea 21(5):490–494
Funding
There was no direct funding for this study. Supported in part by an unrestricted institutional grant from Research to Prevent Blindness, New York, NY, USA.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
All the authors declare that they have no conflict of interest.
Ethical approval
This article does not contain any studies with human participants or animals performed by any of the authors.
Rights and permissions
About this article
Cite this article
Golla, A., Wang, L., Morris, C. et al. Repeatability of central corneal thickness measurements of donor corneas in preservation chamber using Fourier-domain anterior segment optical coherence tomography. Cell Tissue Bank 19, 717–720 (2018). https://doi.org/10.1007/s10561-018-9724-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10561-018-9724-z