Abstract
We have developed an integrative model of the ovine cardiovascular system that simulates the effects of posture and ventricular function to help design the circulatory and pulmonary assist devices often tested in conscious sheep that stand and recline during chronic experiments. Our present focus is the simulation itself and not the evaluation of specific assist devices. Adjusted parameters of the model provide good fits to in vivo experimental data and can describe the hemodynamic changes that follow balloon occlusion of the inferior vena cava and standing. Since circulatory assist devices are often tested in animal preparations of left heart failure, we extended the model to study the effects that standing and inferior vena cava occlusion would have in sheep with primarily systolic left heart dysfunction. We also developed an elastance-based formulation for ventricular muscular work and a sensitivity analysis of the autonomic reflexes affecting blood pressure. The model can analyze the biophysical mechanisms underlying the responses to orthostatic stress and left ventricular dysfunction and should help improve the development and testing of assist devices.
Similar content being viewed by others
References
Bauer F, Jones M, Shiota T, Firstenberg MS, Qin JX, Tsujino H, Kim YJ, Sitges M, Cardon LA, Zetts AD, and Thomas JD: Left ventricular outflow tract mean systolic acceleration as a surrogate for the slope of the left ventricular end-systolic pressure–volume relationship. J Am Coll Cardiol 40: 1320–1327, 2002.
Burkhoff D, and Sagawa K: Ventricular efficiency predicted by an analytical model. Am J Physiol 250: R1021–R1027, 1986.
Chung DC, Niranjan SC, Clark JW, Jr, Bidani A, Johnston WE, Zwischenberger JB, and Traber DL: A dynamic model of ventricular interaction and pericardial influence. Am J Physiol 272: H2942–H2962, 1997.
Clark JW, Jr, Kane GR, and Bourland HM: The feasibility of closed-loop control of intra-aortic balloon pumping. IEEE Trans Biomed Eng 20(6): 404–412, 1973.
Clark JW, Jr, Philippe E, Peterson R, Lande A, and Ellis JR: Automatic control of series-parallel mechanical circulatory assist system for use in severe bi-ventricular failure. Ann Biomed Eng 8: 57–75, 1980.
Cohen SD, and Hindmarsh AC: CVODE, a stiff/nonstiff ODE Solver in C. Comput Phys 10(2): 138–43, 1996.
Fink M, Batzel JJ, and Kappel F: An optimal control approach to modeling the cardiovascular-respiratory system: An application to orthostatic stress. Cardiovasc Eng 4: 27–38, 2004.
Gore RW, and Davis MJ: Mechanics of smooth muscle in isolated single microvessels. Ann Biomed Eng 12: 511–520, 1984.
Heldt T, Shim EB, Kamm RD, and Mark RG: Computational modeling of cardiovascular response to orthostatic stress. J Appl Physiol 92: 1239–1254, 2002.
Jacobsen TN, Morgan BJ, Scherrer U, Vissing SF, Lange RA, Johnson N, Ring WS, Rahko PS, Hanson P, and Victor RG: Relative contributions of cardiopulmonary and sinoaortic baroreflexes in causing sympathetic activation in the human skeletal muscle circulation during orthostatic stress. Circ Res 73: 367–378, 1993.
Katoh N, Sheriff DD, Siu CO, and Sagawa K: Relative importance of low pressoregulator mechanisms after 10% bleeding in rabbits. Am J Physiol Heart Circ Physiol 256: H291–H296, 1989.
Kono S, Nishimura K, Nishina T, Akamatsu T, and Komeda M: Hemodynamics on abrupt stoppage of centrifugal pumps during left ventricular assist. ASAIO J 46: 600–603, 2000.
Kresch E: Design of a non-linear electrical model for veins, PhD thesis, Philadelphia, PA: University of Pennsylvania, 1968.
Kubota T, Alexander JA, Jr, Itaya R, Todaka K, Sugimachi M, Sunagawa K, Nose Y, and Takeshita A: Dynamic effects of carotid sinus baroreflex on ventriculoarterial coupling studied in anesthetized dogs. Circ Res 70: 1044–1053, 1992.
Lande A, Bohrer R, Dudrick P, Clark JW, Jr, and Vered E: Initial design testing of a centrifugal intrathoracic artificial heart and lung. Trans Soc Artif Int Organs. 26: 550–555, 1980.
Leeuwenburg BPJ, Steendijk P, Helbing WA, and Baan J: Indexes of diastolic RV function: Load dependence and changes after chronic RV pressure overload in lambs. Am J Physiol Heart Circ Physiol 282: H1350–H1358, 2002.
Lick SD, Deyo DJ, Wang D, Witt SA, Alpard SK, Harder DD, and Zwischenberger JB: Paracorporeal artificial lung: Perioperative management for survival study in sheep. J Invest Surg. 16(3): 177–184, 2003.
Lu K, Clark JW, Jr, Ghorbel FH, Robertson CS, Ware DL, Zwischenberger JB, and Bidani A: Cerebral autoregulation and gas exchange studied using a human cardiopulmonary model. Am J Physiol Heart Circ Physiol 286: H584–H601, 2004.
Lu K, Clark JW, Jr, Ghorbel FH, Ware DL, and Bidani A: A human cardiopulmonary system model applied to the analysis of the Valsalva maneuver. Am J Physiol Heart Circ Physiol 281: H2661–H2679, 2001.
Lynch WR, Montoya JP, Brant DO, Schreiner RJ, Iannettoni MD, and Barlett RH: Hemodynamic effect of a low-resistance artificial lung in series with the native lungs of sheep. Ann Thorac Surg 69: 351–356, 2000.
Nishida T, Meyns B, Zietkiewicz M, Perek B, Xia Z, Goebel C, Reul H, and Flameng W: The effect of sudden failure of a rotary blood pump on left ventricular performance in normal and failing hearts. Artif Organs 24(11): 893–898, 2000.
Olansen JB, Clark JW, Jr, Khoury D, Ghorbel F, and Bidani A: A closed-loop model of the canine cardiovascular system that includes ventricular interaction. Comput Biomed Res 33: 260–295, 2000.
Olufsen M, Tran H, and Ottesen J: Modeling cerebral blood flow control during posture change from sitting to standing. Cardiovasc Eng 4: 47–58, 2004.
Pagani M, Mirsky I, Baig H, Manders WT, Kerkhof P, and Vatner SF: Effects of age on aortic pressure-diameter and elastic stiffness-stress relationships in unanesthetized sheep. Circ Res 44: 420–429, 1979.
Peterson K, Ozawa ET, Pantalos GM, and Sharp MK: Numerical simulation of the influence of gravity and posture on cardiac performance. Ann Biom Eng 30: 247–259, 2002.
Philippe E, Clark JW, Jr, Lande A, and Ellis JR: Microprocessor control of intra-aortic balloon pumping. Ann Biomed Eng 8: 209–224, 1980.
Rich PB, Reickert CA, Sawada S, Awad SS, Lynch WR, Johnson KJ, and Hirschl RB: Effects of rate and inspiratory flow on ventilator-induced lung injury. J Trauma 49: 903–911, 2000.
Segers P, Steendijk P, Stergiopulos N, and Westerhof N: Predicting systolic and diastolic aortic blood pressure and stroke volume in the intact sheep. J Biomechanics 34: 41–50, 2001.
Slama K, Gesch M, Bock JC, Pietschmann SM, Schaffartzik W, and Pison U: Unilateral lung edema: Effects on pulmonary gas exchange, hemodynamics, and pulmonary perfusion distribution. J Appl Physiol 89: 1513–1521, 2000.
Snyder MF, and Rideout VV: Computer simulation studies of the venous circulation. IEEE Trans Biomed Eng 16: 325–334, 1969.
Sugi K, Newald J, Traber LD, Maguire JP, Herndon DN, Schlag G, and Traber DL: Cardiac dysfunction after acute endotoxin administration in conscious sheep. Am J Physiol Heart Circ Physiol 260: H1474–H1481, 1991.
Sunagawa K, Kawada T, and Nakahara T: Dynamic nonlinear vago-sympathetic interaction regulating heart rate. Heart Vessels 13: 157–174, 1998.
Takagaki M, Rottenberg D, McCarthy PM, Smedira NG, Dessoffy R, Ahmadi MA, Shoshani D, and Fukamachi K: A novel miniature ventricular assist device for hemodynamic support. ASAIO J 47: 412–416, 2001.
Wells SM, Langille BL, and Adamson SL: In vivo and in vitro mechanical properties of the sheep thoracic aorta in the perinatal period and adulthood. Am J Physiol Heart Circ Physiol 274: H1749–H1760, 1998.
Wesseling KH, and Settels JJ: Circulatory model of baro- and cardiopulmonary reflexes. In Di Rienzo M, Mancia G, Parati G, Pedotti A, and Zanchetti A, Eds, Blood Pressure and Heart Rate Variability. Amsterdam, the Netherlands: IOS, 1993, pp. 56–66.
Westerhof N: Cardiac work and efficiency. Cardiovasc Res 48: 4–7, 2000.
Zietkiewicz M, Perek B, Meyns B, Mesotten L, Dispersyn G, Nishimura Y, and Flameng W: Chronic heart failure model induced by coronary embolization in sheep. Int J Artif Organs 22: 499–504, 1999.
Zwischenberger JB, Wang D, Lick SD, Deyo DJ, Alpard SK, and Chambers SD: The paracorporeal artifical lung improves 5-day outcomes from lethal smoke/burn-induced acute respiratory distress syndrome in sheep. Ann Thorac Surg. 74(4): 1011–1016, 2002.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Ha, R.R., Qian, J., Ware, D.L. et al. An Integrative Cardiovascular Model of the Standing and Reclining Sheep. Cardiovasc Eng 5, 53–76 (2005). https://doi.org/10.1007/s10558-005-5341-0
Issue Date:
DOI: https://doi.org/10.1007/s10558-005-5341-0