Abstract
The purpose of this study is to evaluate the prognostic value of myocardial perfusion SPECT obtained in CZT cameras (CZT–SPECT) with multipinhole collimation in obese patients. CZT–SPECT may be technically challenging in the obese, and its prognostic value remains largely unknown. Patients underwent single-day, rest/stress (supine and prone) imaging. Images were visually inspected and graded as poor, fair or good/excellent. Summed stress and difference scores (SSS and SDS, respectively) were converted into percentages of total perfusion defect and of ischemic defect by division by the maximum possible score. Obesity was defined as a body mass index (BMI) ≥ 30 kg/m2 and classified as class I (BMI 30–34.9 kg/m2), II (BMI 35–39.9 kg/m2), or III (BMI ≥ 40 kg/m2). Patients were followed-up by telephone interview for the occurrence of all-cause death, myocardial infarction or revascularization. A Cox proportional hazards analysis was used to assess the independent predictors of death. Among 1396 patients, 365 (26.1 %) were obese (mean BMI 33.9 ± 3.6; 17.5 % class I, 3.4 % class II, and 3.4 % class III). Image quality was good/excellent in 94.5 % of the obese patients. The annualized mortality rates were not significantly different among obese and non-obese patients, being <1 % with normal CZT–SPECT, and increased with the degree of scan abnormality in both obese and non-obese patients. Age, the use of pharmacologic stress and an abnormal CZT–SPECT, but not obesity, were independent predictors of death. In obese patients, single-day rest/stress CZT–SPECT with a multipinhole camera provides prognostic discrimination with high image quality.
Similar content being viewed by others
References
www.who.int/topics/obesity. Accessed on 05 Jan 2015
Berman DS, Hachamovitch R, Kiat H, Cohen I, Cabico JA, Wang FP, Friedman JD, Germano G, Van Train K, Diamond GA (1995) Incremental value of prognostic testing in patients with known or suspected ischemic heart disease: a basis for optimal utilization of exercise technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography. J Am Coll Cardiol 26:639–647
Botvinick EH, Taradash MR, Shames DM et al (1978) Thallium-201 myocardial perfusion scintigraphy for the clinical clarification of normal, abnormal and equivocal electrocardiographic stress tests. Am J Cardiol 41:43–51
Brown KA (1991) Prognostic value of thallium-201 myocardial perfusion imaging. A diagnostic tool comes of age. Circulation 83:363–381
DePuey EG (1994) How to detect and avoid myocardial perfusion SPECT artifacts. J Nucl Med 35:699–702
Sharir T, Ben-Haim S, Merzon K, Prochorov V, Dickman D, Berman DS (2008) High-speed myocardial perfusion imaging initial clinical comparison with conventional dual detector anger camera imaging. JACC Cardiovasc Imaging 1:156–163
Buechel RR, Herzog BA, Husmann L et al (2010) Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: first clinical validation. Eur J Nucl Med Mol Imaging 37:773–778
Sharir T, Slomka PJ, Hayes SW et al (2010) Multicenter trial of high-speed versus conventional single-photon emission computed tomography imaging quantitative results of myocardial perfusion and left ventricular function. J Am Coll Cardiol 55:1965–1974
Herzog BA, Buechel RR, Katz R et al (2010) Nuclear myocardial perfusion imaging with a cadmium-zinc-telluride detector technique: optimized protocol for scan time reduction. J Nucl Med 51:46–51
Gimelli A, Bottai M, Giorgetti A, Genovesi D, Filidei E, Marzullo P (2012) Evaluation of ischaemia in obese patients: feasibility and accuracy of a low-dose protocol with a cadmium-zinc telluride camera. Eur J Nucl Med Mol Imaging 39:1254–1261
Fiechter M, Gebhard C, Fuchs TA et al (2012) Cadmium-zinc-telluride myocardial perfusion imaging in obese patients. J Nucl Med 53:1401–1406
Schwartz RG, Wexler O, Peterson B, Schwartz AM, Mis FJ, Mackin M (2013) Cadmium-zinc-telluride SPECT in very morbidly obese patients routinely provides high-diagnostic-quality myocardial perfusion imaging. J Nucl Med 54:661–662
World Health Organization. BMI classification. http://apps.who.int/bmi
Henzlova MJ, Cerqueira MD, Hansen CL, Mahmarian JJ, Yao SS (2009) ASNC imaging guidelines for nuclear cardiology procedures: stress protocols and tracers. J Nucl Cardiol 16:331–361
Berman DS, Hachamovitch R, Kiat H, Cohen I, Cabico JA, Wang FP, Friedman JD, Germano G, Van Train K, Diamond GA (1995) Incremental value of prognostic testing in patients with known or suspected ischemic heart disease: a basis for optimal utilization of exercise technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography. J Am Coll Cardiol 26:639–647
Hachamovitch R, Rozanski A, Shaw L, Stone G, Thomson L, Friedman J et al (2011) Impact of ischaemia and scar on the therapeutic benefit derived from myocardial revascularization vs. medical therapy among patients undergoing stress-rest myocardial perfusion scintigraphy. Eur Heart J 32:1012–1024
Sturm R (2007) Increases in morbid obesity in the USA: 2000–2005. Public Health 121:492–496
McGee DL, Diverse Populations Collaboration (2005) Body mass index and mortality: a meta-analysis based on person-level data from twenty-six observational studies. Ann Epidemiol 15:87–97
Berrington de Gonzalez A, Hartge P, Cerhan JR et al (2010) Body-mass index and mortality among 1.46 million white adults. N Engl J Med 363:2211–2219
Ghanem MA, Kazim NA, Elgazzar AH (2011) Impact of obesity on nuclear medicine imaging. J Nucl Med Technol 39:40–50
Duvall WL, Croft LB, Corriel JS et al (2006) SPECT myocardial perfusion imaging in morbidly obese patients: image quality, hemodynamic response to pharmacologic stress, and diagnostic and prognostic value. J Nucl Cardiol 13:202–209
Wosnitzer B, Gadiraju R, Depuey G (2011) The truncation artifact. J Nucl Cardiol 18:187–191
Nakazato R, Slomka PJ, Fish M et al (2015) Quantitative high-efficiency cadmium-zinc telluride SPECT with dedicated parallel-hole collimation system in obese patients: results of a multi-center study. J Nucl Cardiol 22:266–275
DeCicco AE, Sokil AB, Marhefka GD, Reist K, Hansen CL (2015) Feasibility of SPECT myocardial perfusion imaging in the super-obese using a multi-head semiconductor camera with attenuation correction. J Nucl Cardiol 22:344–350
Mokdad AH, Ford ES, Bowman BA, Dietz WD, Vinicor F, Bales VS, Marks JS (2003) Prevalence of obesity, diabetes, and obesity-related health risk factors, 2001. JAMA 289:76–79
Hachamovitch R, Berman DS, Kiat H, Cohen I, Cabico A, Friedman JD, Diamond GA (1996) Exercise myocardial perfusion SPECT in patients with known or suspected coronary artery disease. Incremental prognostic value and use in risk stratification. Circulation 93:905–914
Bourque JM, Beller GA (2011) Stress myocardial perfusion imaging for assessing prognosis: an update. JACC Cardiovasc Imaging 4:1305–1319
Romero-Corral A, Montori VM, Somers VK, Korinek J, Thomas RJ, Allison TG, Mookadam F, Lopez-Jimenez F (2006) Association of bodyweight with total mortality and with cardiovascular events in coronary artery disease: a systematic review of cohort studies. Lancet 368:666–678
Acknowledgments
The authors had no financial support for this research.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Ethical standards
All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments of comparable ethical standards.
Informed consent
Informed consent was obtained from all individual participants included in the study.
Electronic supplementary material
Below is the link to the electronic supplementary material.
Rights and permissions
About this article
Cite this article
De Lorenzo, A., Peclat, T., Amaral, A.C. et al. Prognostic evaluation in obese patients using a dedicated multipinhole cadmium-zinc telluride SPECT camera. Int J Cardiovasc Imaging 32, 355–361 (2016). https://doi.org/10.1007/s10554-015-0770-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10554-015-0770-3