Narrowing the phase window width in prospectively ECG-gated single heart beat 320-detector row coronary CT angiography

  • Original Paper
  • Published:
The International Journal of Cardiovascular Imaging Aims and scope Submit manuscript

Abstract

Purpose To evaluate the relationship between the phase window width and image quality in prospectively ECG-gated 320-detector row coronary CTA, and to evaluate the relationship between heart rate and the number of cardiac phases with diagnostic quality images. Methods Thirty-six phases (60–95% R-R, 1% increments) were reconstructed in 41 consecutive prospectively gated single R-R 320 × 0.5 mm detector row coronary CTA patients. For each phase, two cardiovascular imagers retrospectively documented the phases considered diagnostic for the left anterior descending (LAD), left circumflex (LCx), and right coronary artery (RCA). The smallest phase window width including at least one diagnostic phase for 95% of coronary arteries was determined, and after accounting for sampling variation, the same smallest window width was estimated for the general population. Inter-rater agreement was determined. A linear regression model evaluated the relationship between heart rate and width of diagnostic phase windows. Results Widening the phase window width increases the proportion of coronary arteries with at least one diagnostic phase. Among the 41 patients, 95% of vessels had a diagnostic phase in the 72–77% phase window. Accounting for sampling variation, the 72–81% phase window has a 0.95 probability of including a diagnostic phase for 95% of coronary arteries in the general population. Interobserver agreement was 0.959 with 0.95 confidence interval [0.908, 0.987]. Patients with a lower heart rate had significantly more diagnostic phases. Conclusions For prospectively ECG-gated single heart beat coronary CTA, a phase window width of 10% will reduce patient radiation and yield diagnostic images in >90% of patients. Heart rate control is an important component of 320-detector row prospectively gated CT dose reduction.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Husmann L, Valenta I, Gaemperli O et al (2008) Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating. Eur Heart J 29:191–197. doi:10.1093/eurheartj/ehm613

    Article  PubMed  Google Scholar 

  2. Earls JP, Berman EL, Urban BA et al (2008) Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose. Radiology 246:742–753. doi:10.1148/radiol.2463070989

    Article  PubMed  Google Scholar 

  3. Shuman WP, Branch KR, May JM et al (2008) Prospective versus retrospective ECG gating for 64-detector CT of the coronary arteries: comparison of image quality and patient radiation dose. Radiology (in press)

  4. Rybicki FJ, Otero HJ, Steigner ML et al (2008) Initial evaluation of coronary images from 320-detector row computed tomography. Int J Cardiovasc Imaging 24:535–546. doi:10.1007/s10554-008-9308-2

    Article  PubMed  Google Scholar 

  5. Wang Y, Vidan E, Bergman GW (1999) Cardiac motion of coronary arteries: variability in the rest period and implications for coronary MR angiography. Radiology 213:751–758

    PubMed  CAS  Google Scholar 

  6. Weinreb JC, Larson PA, Woodard PK et al (2005) American college of radiology clinical statement on noninvasive cardiac imaging. Radiology 235:723–727. doi:10.1148/radiol.2353050358

    Article  PubMed  Google Scholar 

  7. Einstein AJ, Henzlova MJ, Rajagopalan S (2007) Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography. JAMA 298:317–323. doi:10.1001/jama.298.3.317

    Article  PubMed  CAS  Google Scholar 

  8. Shu KM, MacKenzie JD, Smith JB et al (2006) Lowering the thyroid dose in screening examinations of the cervical spine. Emerg Radiol 12:133–136. doi:10.1007/s10140-005-0462-8

    Article  PubMed  Google Scholar 

Download references

Acknowledgment

We acknowledge Richard T. Mather for providing the CT dose estimates.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Frank J. Rybicki.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Steigner, M.L., Otero, H.J., Cai, T. et al. Narrowing the phase window width in prospectively ECG-gated single heart beat 320-detector row coronary CT angiography. Int J Cardiovasc Imaging 25, 85–90 (2009). https://doi.org/10.1007/s10554-008-9347-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10554-008-9347-8

Keywords

Navigation