Abstract
Ablative fractional resurfacing (AFR) represents a new treatment potential for various skin conditions and new laser devices are being introduced. It is important to gain information about the impact of laser settings on the dimensions of the created laser channels for obtaining a safe and efficient treatment outcome. The aim of this study was to establish a standard model to document the histological tissue damage profiles after AFR and to test a new laser device at diverse settings. Ex vivo abdominal pig skin was treated with a MedArt 620, prototype fractional carbon dioxide (CO2) laser (Medart, Hvidovre, Denmark) delivering single microbeams (MB) with a spot size of 165 μm. By using a constant pulse duration of 2 ms, intensities of 1–18 W, single and 2–4 stacked pulses, energies were delivered in a range from 2–144 mJ/MB. Histological evaluations included 3–4 high-quality histological measurements for each laser setting (n = 28). AFR created cone-shaped laser channels. Ablation depths varied from reaching the superficial dermis (2 mJ, median 41 μm) to approaching the subcutaneous fat (144 mJ, median 1,943 μm) and correlated to the applied energy levels in an approximate linear relation (r2 = 0.84, p < 0.001). The dermal ablation width increased slightly within the energy range of 4–144 mJ (median 163 μm). The thickness of the coagulation zone reached a plateau around 65 μm at energies levels above 16 mJ. The calculated volumes of ablated tissue increased with increasing energies. We suggest this ex vivo pig skin model to characterize AFR laser channels histologically.
Similar content being viewed by others
References
Manstein D, Herron GS, Sink RK, Tanner H, Anderson RR (2004) Fractional photothermolysis: a new concept for cutaneous remodeling using microscopic patterns of thermal injury. Lasers Surg Med 34:426–438
Khan MH, Sink RK, Manstein D, Eimerl D, Anderson RR (2005) Intradermally focused infrared laser pulses: thermal effects at defined tissue depths. Lasers Surg Med 36:270–280
Doherty SD, Doherty CB, Markus JS, Markus RF, Markus RF (2009) A paradigm for facial skin rejuvenation. Facial Plast Surg 25:245–251
Tierney EP, Kouba DJ, Hanke CW (2009) Review of fractional photothermolysis: treatment indications an efficacy. Dermatol Surg 35:1445–1461
Hantash BH, Bedi VP, Chan KF, Zachary CB (2007) Ex vivo histological characterization of a novel ablative fractional resurfacing device. Lasers Surg Med 39:87–95
Hantash BH, Bedi VP, Kapadia B, Rahman Z, Jiang K, Tanner H, Chan KF, Zachary CB (2007) In vivo histological evaluation of a novel ablative fractional resurfacing device. Lasers Surg Med 39:96–107
Tannous Z (2007) Fractional resurfacing. Clin Dermatol 25:480–486
Bodendorf MC, Grunewald S, Wetzig T, Simon JC, Paasch U (2009) Fractional laser skin therapy. J Ger Soc Dermatol 7:301–308
Helbig D, Bodendorf MO, Grunewald S, Kendler M, Simon JC, Paasch U (2009) Immunohistochemical investigation of wound healing in response to fractional photothermolysis. J Biomed 14:064044
Geronemus RG (2006) Fractional photothermolysis: current and future applications. Lasers Surg Med 38:169–176
Jih MH, Kimyai-Asadi A (2008) Fractional photothermolysis: a review and update. Semin Cutan Med Surg 27:63–71
Allemann IB, Kaufman J (2010) Fractional photothermolysis-an update. Lasers Med Sci 25:137–144
Laubach HJ, Tannous Z, Anderson RR, Manstein D (2006) Skin responses to fractional photothermolysis. Lasers Surg Med 38:142–149
Dierickx CC, Khatri KA, Tannous ZS, Childs JJ, Cohen RH, Erofeev A, Tabatadze D, Yaroslavsky IV, Altshuler GB (2008) Micro-fractional ablative skin resurfacing with two novel erbium laser systems. Lasers Surg Med 40:113–123
Trelles MA, Vélez M, Mordon S (2008) Correlation of histological findings of single session Er:YAG skin fractional resurfacing with various passes and energies and the possible clinical implications. Lasers Surg Med 40:174–177
Zelickson BD, Walgrave SE, Al-Arashi MYH, Altshuler GB, Yaroslavsky IV, Childs JJ, Cohen RH, Erofeev AV, Depina EF, Smirnov MZ, Kist DA, Tabatadze DR (2009) Semi-automated method of analysis of horizontal histological sections of skin for objective evaluation of fractional devices. Lasers Surg Med 41:634–642
Saluja R, Khoury J, Detwiler SP, Goldman MP (2009) Histologic and clinical response to varying density settings with a fractionally scanned carbon dioxide laser. J Drugs Dermatol 8:17–20
Simon GA, Maibach HI (2000) The pig as an experimental animal model of percutaneous permeation in man: qualitative and quantitative observations—an overview. Skin Pharmacol Appl Skin Physiol 13:229–234
Acknowledgements
The authors thank Olav Balle-Petersen for technical support, Dorthe L. Jensen for assistance to perform the study, MedArt, Hvidovre, Denmark, provided the prototype CO2 laser, MedArt 620, as a loan for study procedures.
Author information
Authors and Affiliations
Corresponding author
Additional information
Conflict of interest
The authors state no conflicts of interest.
Rights and permissions
About this article
Cite this article
Skovbølling Haak, C., Illes, M., Paasch, U. et al. Histological evaluation of vertical laser channels from ablative fractional resurfacing: an ex vivo pig skin model. Lasers Med Sci 26, 465–471 (2011). https://doi.org/10.1007/s10103-010-0829-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10103-010-0829-2