Abstract
Although there are many studies on catheter-related infection, there are scarce data about the influence of tracheostomy in the incidence of central venous catheter-related bacteremia (CRB). In this cohort study, we found a higher incidence of CRB in patients with tracheostomy than without (11.25 vs. 1.43 per 1,000 catheter-days; odds ratio [OR] = 7.99; 95% confidence interval [CI] = 4.38–infinite; P < 0.001). Besides, we found a higher incidence of CRB in patients with tracheostomy using the jugular access compared to subclavian access (21.64 vs. 5.11 per 1,000 catheter-days; OR = 4.23; 95% CI = 1.44–infinite; P = 0.0097).
References
Collignon P, Soni N, Pearson I, Sorrell T, Woods P (1988) Sepsis associated with central vein catheters in critically ill patients. Intensive Care Med 14:227–231. doi:10.1007/BF00717995
Goetz AM, Wagener MM, Miller JM, Muder RR (1998) Risk of infection due to central venous catheters: effect of site of placement and catheter type. Infect Control Hosp Epidemiol 19:842–845
Deshpande KS, Hatem C, Ulrich HL, Currie BP, Aldrich TK, Bryan-Brown CW, Kvetan V (2005) The incidence of infectious complications of central venous catheters at the subclavian, internal jugular, and femoral sites in an intensive care unit population. Crit Care Med 33:13–20. doi:10.1097/01.CCM.0000149838.47048.60
Lorente L, Villegas J, Martín MM, Jiménez A, Mora ML (2004) Catheter-related infection in critically ill patients. Intensive Care Med 30(8):1681–1684. doi:10.1007/s00134-004-2332-3
Lorente L, Henry C, Martín MM, Jiménez A, Mora ML (2005) Central venous catheter-related infection in a prospective and observational study of 2,595 catheters. Crit Care 9:R631–R635. doi:10.1186/cc3824
Lorente L, Jiménez A, Castedo J, Galván R, García C, Martín MM, Mora ML (2007) Internal jugular venous catheter-related bacteremia according to central and posterior accesses. Intensive Care Med 33(6):1071–1075. doi:10.1007/s00134-007-0647-6
Lorente L, Jiménez A, Galván R, García C, Castedo J, Martín MM, Mora ML (2007) Equivalence of posterior internal jugular and subclavian accesses in the incidence of central venous catheter related bacteremia. Intensive Care Med 33:2230–2231. doi:10.1007/s00134-007-0853-2
Lorente L, Jiménez A, García C, Galván R, Castedo J, Martín MM, Mora ML (2008) Catheter-related bacteremia from femoral and central internal jugular venous access. Eur J Clin Microbiol Infect Dis 27(9):867–781. doi:10.1007/s10096-008-0507-5
Lorente L, Lecuona M, Ramos MJ, Jiménez A, Mora ML, Sierra A (2008) The use of rifampicin-miconazole-impregnated catheters reduces the incidence of femoral and jugular catheter-related bacteremia. Clin Infect Dis 47(9):1171–1175. doi:10.1086/592253
Michel L, McMichan JC, Bachy JL (1979) Tracheostomy and indwelling central venous line: a hazardous combination? Intensive Care Med 5(2):83–86. doi:10.1007/BF01686052
Dusan C, Bouchard P, Goudot B, Grozel JM, Perdrix JP, Banssillon V (1981) Bacteriologic study of indwelling central venous catheters. Factors influencing the risk of microbial colonization and sepsis. Anesth Analg (Paris) 38(7–8):347–350
Garnacho-Montero J, Aldabó-Pallás T, Palomar-Martínez M, Vallés J, Almirante B, Garcés R, Grill F, Pujol M, Arenas-Giménez C, Mesalles E, Escoresca-Ortega A, de Cueto M, Ortiz-Leyba C (2008) Risk factors and prognosis of catheter-related bloodstream infection in critically ill patients: a multicenter study. Intensive Care Med 34(12):2185–2193. doi:10.1007/s00134-008-1204-7
Pearson ML (1996) Guideline for prevention of intravascular device-related infections. Part I. Intravascular device-related infections: an overview. The Hospital Infection Control Practices Advisory Committee. Am J Infect Control 24:262–277
O’Grady NP, Alexander M, Dellinger EP, Gerberding JL, Heard SO, Maki DG, Masur H, McCormick RD, Mermel LA, Pearson ML, Raad II, Randolph A, Weinstein RA (2002) Guidelines for the prevention of intravascular catheter-related infections. Centers for Disease Control and Prevention. MMWR Recomm Rep 51:1–29
Lorente L, Huidobro MS, Martín MM, Jiménez A, Mora ML (2004) Accidental catheter removal in critically ill patients: a prospective and observational study. Crit Care 8(4):R229–R233. doi:10.1186/cc2874
Maki DG, Weise CE, Sarafin HW (1977) A semiquantitative culture method for identifying intravenous-catheter-related infection. N Engl J Med 296:1305–1309
Moro ML, Viganò EF, Cozzi Lepri A (1994) Risk factors for central venous catheter-related infections in surgical and intensive care units. The Central Venous Catheter-Related Infections Study Group. Infect Control Hosp Epidemiol 15(4 Pt 1):253–264
Mermel LA, McCormick RD, Springman SR, Maki DG (1991) The pathogenesis and epidemiology of catheter-related infection with pulmonary artery Swan-Ganz catheters: a prospective study utilizing molecular subtyping. Am J Med 91(3B):197S–205S. doi:10.1016/0002-9343(91)90369-9
Heard SO, Wagle M, Vijayakumar E, McLean S, Brueggemann A, Napolitano LM, Edwards LP, O’Connell FM, Puyana JC, Doern GV (1998) Influence of triple-lumen central venous catheters coated with chlorhexidine and silver sulfadiazine on the incidence of catheter-related bacteremia. Arch Intern Med 158(1):81–87. doi:10.1001/archinte.158.1.81
Laura R, Degl’Innocenti M, Mocali M, Alberani F, Boschi S, Giraudi A, Arnaud MT, Zucchinali R, Paris MG, Dallara R, Thaler S, Perobelli G, Parfazi S, De Lazzer T, Peron G (2000) Comparison of two different time interval protocols for central venous catheter dressing in bone marrow transplant patients: results of a randomized, multicenter study. The Italian Nurse Bone Marrow Transplant Group (GITMO). Haematologica 85:275–279
Engervall P, Ringertz S, Hagman E, Skogman K, Björkholm M (1995) Change of central venous catheter dressings twice a week is superior to once a week in patients with haematological malignancies. J Hosp Infect 29:275–286. doi:10.1016/0195-6701(95)90274-0
Josephson A, Gombert ME, Sierra MF, Karanfil LV, Tansino GF (1985) The relationship between intravenous fluid contamination and the frequency of tubing replacement. Infect Control 6(9):367–370
Maki DG, Botticelli JT, LeRoy ML, Thielke TS (1987) Prospective study of replacing administration sets for intravenous therapy at 48- vs 72-hour intervals. 72 hours is safe and cost-effective. JAMA 258(13):1777–1781. doi:10.1001/jama.258.13.1777
León C, Alvarez-Lerma F, Ruiz-Santana S, González V, de la Torre MV, Sierra R, León M, Rodrigo JJ (2003) Antiseptic chamber-containing hub reduces central venous catheter-related infection: a prospective, randomized study. Crit Care Med 31(5):1318–1324. doi:10.1097/01.CCM.0000026327.58305.22
Segura M, Alvarez-Lerma F, Tellado JM, Jiménez-Ferreres J, Oms L, Rello J, Baró T, Sánchez R, Morera A, Mariscal D, Marrugat J, Sitges-Serra A (1996) A clinical trial on the prevention of catheter-related sepsis using a new hub model. Ann Surg 223(4):363–369. doi:10.1097/00000658-199604000-00004
Halpin DP, O’Byrne P, McEntee G, Hennessy TP, Stephens RB (1991) Effect of a betadine connection shield on central venous catheter sepsis. Nutrition 7(1):33–34
Niël-Weise BS, Daha TJ, van den Broek PJ (2006) Is there evidence for recommending needleless closed catheter access systems in guidelines? A systematic review of randomized controlled trials. J Hosp Infect 62(4):406–413. doi:10.1016/j.jhin.2005.10.005
Competing interests
None declared.
Funding
Hospital funding.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Lorente, L., Jiménez, A., Martín, M.M. et al. Influence of tracheostomy on the incidence of central venous catheter-related bacteremia. Eur J Clin Microbiol Infect Dis 28, 1141–1145 (2009). https://doi.org/10.1007/s10096-009-0742-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10096-009-0742-4