Abstract
A warning on the danger of unretrieved device fragments and recommendations to mitigate the danger were issued by the Food and Drug Administration in January 2008. The causes of intravascular foreign bodies are classified into three main categories: improper manipulation and usage, device defects, and others, such as patient and anatomical factors. Device failure after long-term use is rarely predicted at the time of approval, since device abnormality is rarely experienced in animal studies and clinical trials conducted during development of the device. Stent fracture due to metal fatigue is one example. Complex complications could occur from simultaneous use of two or more devices with diverse characteristics. The success rate of percutaneous retrieval of intravascular foreign bodies has improved with the advances in commercially available devices. However, the procedure is not always successful and sometimes surgical removal becomes necessary. Appropriate device selection and acquisition of experience in using the device are important. When an intravascular foreign body cannot be retrieved, the risk of complication could be high. Magnetic resonance imaging examination sometimes causes adverse events, including burns due to the heat generated by metal movement. Such information should be correctly recorded. Furthermore, it is necessary to provide patients with adequate information about the characteristics of implanted devices and unretrieved fragments. We reviewed the literature on unretrieved medical device fragments and include articles that describe the Japanese experience.
Similar content being viewed by others
References
Fischer RA. Danger: beware of unretrieved device fragments. Nursing 2007;37(11):17
FDA Public Health Notification. Unretrieved device fragments. http://www.fda.gov/cdrh/safety/011508-udf.html. Accessed: August 29, 2008
What to do about unretrieved device fragments. FDA Patient Safety News: Show #71. http://www.accessdata.fda.gov/scripts/cdrh/cfdocs/psn/printer.cfm?id=725. Accessed August 29, 2008
Margulis AR. Recent advances in clinical diagnostic radiology. 4. Interventional diagnostic roentgenology. Adv Surg 1971;5:88–102
Turner DD, Sommers SC. Accidental passage of a polyethylene catheter from cubital vein to right atrium: report of a fatal case. N Engl J Med 1954;251(18):744–745
Bernhardt LC, Wegner GP, Mendenhall JT. Intravenous catheter embolization to the pulmonary artery. Chest 1970;57(4):329–332
Dotter CT, Rosch J, Bilbao MK. Transluminal extraction of catheter and guide fragments from the heart and great vessels: 29 collected cases. Am J Roentgenol Radium Ther Nucl Med 1971;111(3):467–472
Richardson JD, Grover FL, Trinkle JK. Intravenous catheter emboli. Experience with twenty cases and collective review. Am J Surg 1974;128(6):722–727
Seldinger SI. Catheter replacement of the needle in percutaneous arteriography: a new technique. Acta Radiol 1953;39(5):368–376
Cope C. Intravascular breakage of Seldinger spring guide wires. JAMA 1962;180:1061–1063
Thomas J, Sinclair-Smith B, Bloomfield D, Davachi A. Nonsurgical retrieval of a broken segment of steel spring guide from the right atrium and inferior vena cava. Circulation 1964;30:106–108
Egglin TKP, Dickey KW, Rosenblatt M, Pollak JS. Retrieval of intravascular foreign bodies: experience in 32 cases. AJR Am J Roentgenol 1995;164(5):1259–1264
Gabelmann A, Kramer S, Gorich J. Percutaneous retrieval of lost or misplaced intravascular objects. AJR Am J Roentgenol 2001;176(6):1509–1513
Cekirge S, Weiss JP, Foster RG, Neiman HL, McLean GK. Percutaneous retrieval of foreign bodies: experience with the nitinol goose neck snare. J Vasc Interv Radiol 1993;4(6):805–810
Uno Y, Horita Y, Kanaya H. Successful retrieve of a shaft transection of the balloon catheter using basket clamp during 6Fr TRI: a case report. Coron Interv 2003;2:300–302 (in Japanese)
Horio K, Hosoda K, Ikuta K, Takahashi N, Nababuchi E, Kurihara H. Retrieval of intravascular ultrasound catheter entrapped at the edge of the stent in native forearm hemodialysis shunt: a case report. Jpn J Interv Radiol 2004;19:236 (in Japanese)
Kato T, Kataoka K, Hoshino K, Matsuoka T, Nagao K, Horie T, Miyamoto T, Sato Y, Takatsu Y. A case of intravascular ultrasound catheter entrapment after radius stent implantation. Jpn J Interv Cardiol 2005;20:422–426 (in Japanese)
Kawai H, Tanaka M, Murata Y, Koyasu M, Horibe H, Yanase M, Takemoto K, Nonokawa M, Shimizu S, Watarai M. A case of IVUS catheter detachment after becoming entrapped with stent struts implanted two years before. Jpn Interv Cardiol 2006;21:333–337 (in Japanese)
Rao PS, Sideris EB, Hausdorf G, Rey C, Lloyd TR, Beekman RH, Worms AM, Bourlon F, Onorato E, Khalilullah M, Haddad J. International experience with secundum atrial septal defect occlusion by the buttoned device. Am Heart J 1994;128(5):1022–1035
Chan KC, Godman MJ, Walsh K, Wilson N, Redington A, Gibbs JL. Transcatheter closure of atrial septal defect and interatrial communications with a new self-expanding nitinol double-disc device (Amplatzer septal occluder): multicentre UK experience. Heart 1999;82(3):300–306
Schummer W, Schummer C, Gaser E, Bartunek R. Loss of the guide wire: mishap or blunder? Br J Anaesth 2002;88(1):144–146
Kusminsky RE. Complications of central venous catheterization. J Am Coll Surg 2007;204(4):681–696
Saitoh T, Iwata Y. Displacement of a fragment of guide wire used for the insertion of the SVC catheter. IVR Interv Radiol 2004;19:220 (in Japanese)
Furutani S. Experience of a case with accidental retention of an IVH catheter in a blood vessel. Okayama Red Cross Hosp J Med 2005;16:25–30 (in Japanese)
Yoshii S, Hosaka S, Nakagomi H, Hashimoto R, Matsukawa T, Ueno A. Foreign bodies in the heart and great vessels. Yamanashi Med J 1989;4:89–94 (in Japanese)
Shinya H, Syouji Y, Matsubara M, Takada T, Takeyama N, Tanaka T. Eleven cases of foreign bodies in the heart and/or the large vessels. ICU CCU 1997;21:821–824 (in Japanese)
Sadaoka S, Narita K, Fukuda K. Central venous catheter fragment with embolization into a distal branch of the pulmonary artery in a baby. Jpn J Interv Radiol 2004;19:237 (in Japanese)
Filan PM, Woodward M, Ekert PG. Stuck long line syndrome. Arch Dis Child 2005;90(6):558
Schwartz AJ, Horrow JC, Jobes DR, Ellison N. Guide wires — a caution. Crit Care Med 1981;9(4):347–348
Steele PM, Holmes DR Jr, Mankin HT, Schaff HV. Intravascular retrieval of broken guide wire from the ascending aorta after percutaneous transluminal coronary angioplasty. Cathet Cardiovasc Diagn 1985;11(6):623–628
Krone RJ. Successful percutaneous removal of retained broken coronary angioplasty guidewire. Cathet Cardiovasc Diagn 1986;12(6):409–410
Khonsari S, Livermore J, Mahrer P, Magnusson P. Fracture and dislodgment of floppy guidewire during percutaneous transluminal coronary angioplasty. Am J Cardiol 1986;58(9):855–856
Stellin G, Ramondo A, Bortolotti U. Guidewire fracture: an unusual complication of percutaneous transluminal coronary angioplasty. Int J Cardiol 1987;17(3):339–342
Watson LE. Snare loop technique for removal of broken steerable PTCA wire. Cathet Cardiovasc Diagn 1987;13(1):44–49
Mikolich JR, Hanson MW. Transcatheter retrieval of intracoronary detached angioplasty guidewire segment. Cathet Cardiovasc Diagn 1988;15(1):44–46
Bachenheimer LC, Green CE, Rosing DR, Wallace RB. Surgical removal of the intracoronary portion of a fractured angioplasty guidewire. Am J Cardiol 1988;61(11):946–947
Vrolix M, Vanhaecke J, Piessens J, De Geest H. An unusual case of guide wire fracture during percutaneous transluminal coronary angioplasty. Cathet Cardiovasc Diagn 1988;15(2):99–102
Ichikawa K, Tazima H, Murata T, Kumasaki T. Retrieval of a cut guide wire for percutaneous cardiopulmonary support. Jpn J Interv Radiol 2004;19:233 (in Japanese)
Foster-Smith K, Garratt KN, Holmes DR Jr. Guidewire transection during rotational coronary atherectomy due to guide catheter dislodgement and wire kinking. Cathet Cardiovasc Diagn 1995;35(3):224–227
Takiya H, Sasaki H, Sawamura T, Kawai H, Sugishita F, Watanabe S. Surgical removal of guidewire fragment following percutaneous transluminal coronary angioplasty. Jpn Ann Thorac Surg 1991;11:158–161 (in Japanese)
Yamamoto K, Yamaguhi T, Kiuura K. Successful removal of guidewire fragment trapped in stent strut during PCI: entrapment of an ICE-coated polymer-sleeve wire without a coil. Jpn Interv Cardiol 2003;18:584–589 (in Japanese)
Karthik S, Silverton P, Blaxill JA, O’Regan DJ. Successful outcome of emergency coronary artery bypass grafting and retrieval of entrapped stent, angioplasty balloon, and guidewire. Ann Thorac Surg 2005;79(3):1032–1034
Sasseen BM, Burke JA, Shah R, Costa MA, Zenni M, Gilmore P, Bass TA. Intravascular ultrasound catheter entrapment after coronary artery stenting. Cathet Cardiovasc Interv 2002;57(2):229–233
Okamoto K, Inoue Y, Usui K, Ohya T, Arii S, Iwai T. Guide wire ablation during central venous catheter insertion: a case report. J Jpn Soc Pediat Surg 2002;38:1096–1099 (in Japanese)
Chu FSK, Tso WK, Lie AKW. Percutaneous retrieval of a chronic foreign body with both intravascular and extravascular components. Australas Radiol 2007;51(2):179–181
Sakaguchi S, Kubota Y, Higashiura W, Nagata T, Ooishi H, Yoshikawa K. A guide wire fracture during intervention of complete occlusion of iliac artery: a case report. J Jpn Radiol Soc 2002;62:451 (in Japanese)
Matsuura T, Inoue K. Case report: transvenous removal of migrated metallic stent in the coronary artery by goose-neck snare. IVR Interv Radiol 2004;19(3):221 (in Japanese)
Misumi T, Nishikawa K, Gotoh T, Chino M, Yamane M. A case of successful surgical retrieval of the intracoronary interlocked Palmaz-Schatz stent. J Jpn Assn Thorac Surg 1995;43(6):875–878 (in Japanese)
Chowdhury PS, Ramos RG. Coronary-stent fracture. N Engl J Med 2002;347(8):581
Sianos G, Hofma S, Ligthart JMR, Saia F, Hoye A, Lemos PA, Serruys PW. Stent fracture and restenosis in the drug-eluting stent era. Cathet Cardiovasc Interv 2004;61(1):111–116
Morice MC, Serruys PW, Eduardo Sousa J, Fajadet J, Hayashi EB, Perin M, Colombo A, Schuler G, Barragan P, Guagliumi G, Molnàr F, Falotico R. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 2002;346(23):1773–1780
Grube E, Silber S, Hauptmann KE, Mueller R, Buellesfeld L, Gerckens U, Russell ME. Six- and twelve-month results from a randomized, double-blind trial on a slow-release paclitaxel-eluting stent for de novo coronary lesions. Circulation 2003;107(1):38–42
Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O’shaughnessy C, Caputo RP, Kereiakes DJ, Williams DO, Teirstein PS, Jaeger JL, Kuntz RE. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 2003;349(14):1315–1323
Lee MS, Jurewitz D, Aragon J, Forrester J, Makkar RR, Kar S. Stent fracture associated with drug-eluting stents: clinical characteristics and implications. Cathet Cardiovasc Interv 2007;69(3):387–394
Takiuchi S, Fukumono A, Yabuki M, Terasoma K, Higashino Y. First clinical experience of Cyperstent fracture and dislodgement from coronary artery 10 days after implantation. Jpn Interv Cardiol 2007;22:457–462 (in Japanese)
Makita Y, Okamoto M, Hashimoto M, Sueda T, Yamasaki S, Fujii Y, Kajihara K, Iwamoto A. IVUS findings of restenosis caused by a Sirolimus-eluting stent fracture. Jpn Interv Cardiol 2006;21:67–71 (in Japanese)
Kadota S, Izuhara M, Baba O, Moriwaki S, Shioji K, Takeuchi Y, Uegaito T, Matsuda M. A Driver stent fracture causing early-restenosis: a case report. Jpn J Cathet Ther 2007;7:160–164 (in Japanese)
Koh TW, Mathur A. Coronary stent fracture in a saphenous vein graft to right coronary artery — successful treatment by the novel use of the Jomed coronary stent graft: case report and review of the literature. Int J Cardiol 2007;119(2):e43–e45
Min PK, Yoon YW, Moon Kwon H. Delayed strut fracture of sirolimus-eluting stent: a significant problem or an occasional observation? Int J Cardiol 2006;106(3):404–406
Surmely JF, Kinoshita Y, Dash D, Matsubara T, Terashima M, Ehara M, Ito T, Nasu K, Takeda Y, Tanaka N, Suzuki T, Katoh O. Stent strut fracture-induced restenosis in a bifurcation lesion treated with the crush stenting technique. Circ J 2006;70(7):936–938
Halkin A, Carlier S, Leon MB. Late incomplete lesion coverage following Cypher stent deployment for diffuse right coronary artery stenosis. Heart 2004;90(8):e45
Aoki A, Tanabe J, Inami T, Ogano M, Kobayashi N, Hosokawa Y, Yokoyama H, Takano H, Mizuno K. Late multiple stent fractures following deployment of sirolimus-eluting stents for diffuse right coronary artery stenosis. Int Heart J 2007;48(6):767–772
Okumura M, Ozaki Y, Ishii J, Kan S, Naruse H, Matsui S, Ishikawa M, Hattori K, Gochi T, Nakano T, Yamada A, Kato S, Motoyama S, Sarai M, Takagi Y, Ismail TF, Nomura M, Hishida H. Restenosis and stent fracture following sirolimus-eluting stent (SES) implantation — a serial quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS) study. Circ J 2007;71(11):1669–1677
Aoki J, Nakazawa G, Tanabe K, Hoye A, Yamamoto H, Nakayama T, Onuma Y, Higashikuni Y, Otsuki S, Yagishita A, Yachi S, Nakajima H, Hara K. Incidence and clinical impact of coronary stent fracture after sirolimus-eluting stent implantation. Cathet Cardiovasc Interv 2007;69(3):380–386
Yagi S, Kimura T, Hayashi I, Nishiuchi T. Acute coronary syndrome due to hinge movement of a bare-metal stent. Int J Cardiol 2008;123(3)e64–e66
Yamada KP, Koizumi T, Yamaguchi H, Kaneda H, Bonneau HN, Honda Y, Fitzgerald PJ. Serial angiographic and intravascular ultrasound analysis of late stent strut fracture of sirolimus-eluting stents in native coronary arteries. Int J Cardol 2008;130(2):255–259
Obata JE, Takano H, Kitta Y, Nakamura T, Mende A, Umetani K, Kugiyama K. Dislodgement of a fractured sirolimus-eluting stent. Jpn J Interv Cardiol 2007;22(6):542–546 (in Japanese)
Immer FF, Heller G, Dick F, Carrel TP. Fractured and embolized coronary stent mimicking significant internal carotid stenosis. Ann Thorac Surg 2006;82(2):739–740
Kang WY, Kim W, Kim HG. Drug-eluting stent fracture occurred within 2 days after stent implantation. Int J Cardiol 2007;120(2):273–275
Shite J, Matsumoto D, Yokoyama M. Sirolimus-eluting stent fracture with thrombus: visualization by optical coherence tomography. Eur Heart J 2006;27(12):1389
Brilakis ES, Maniu C, Wahl M, Barsness G. Unstable angina due to stent fracture. J Invasive Cardiol 2004;16(9):545
Makaryus AN, Lefkowitz L, Lee ADK. Coronary artery stent fracture. Int J Cardiovasc Imaging 2007;23(3):305–309
Camenzind E, Steg PG, Wijns W. Stent thrombosis late after implantation of first-generation drug-eluting stents: a cause for concern. Circulation 2007;115(11):1440–1455
Mauri L, Hsieh WH, Massaro JM, Ho KKL, D’Agostino R, Cutlip DE. Stent thrombosis in randomized clinical trials of drug-eluting stents. N Engl J Med 2007;356(10):1020–1029
Takebayashi H, Mintz GS, Carlier SG, Kobayashi Y, Fujii K, Yasuda T, Costa RA, Moussa I, Dangas GD, Mehran R, Lansky AJ, Kreps E, Collins MB, Colombo A, Stone GW, Leon MB, Moses JW. Nonuniform strut distribution correlates with more neointimal hyperplasia after sirolimus-eluting stent implantation. Circulation 2004;110(22):3430–3434
Lemos PA, Saia F, Ligthart JMR, Arampatzis CA, Sianos G, Tanabe K, Hoye A, Degertekin M, Daemen J, McFadden E, Hofma S, Smits PC, De Feyter P, Van der Giessen WJ, Van Domburg RT, Serruys PW. Coronary restenosis after sirolimus-eluting stent implantation: morphological description and mechanistic analysis from a consecutive series of cases. Circulation 2003;108(3):257–260
Stone GW, Moses JW, Ellis SG, Schofer J, Dawkins KD, Morice MC, Colombo A, Schampaert E, Grube E, Kirtane AJ, Cutlip DE, Fahy M, Pocock SJ, Mehran R, Leon MB. Safety and efficacy of sirolimus- and paclitaxel-eluting coronary stents. N Engl J Med 2007;356(10):998–1008
Duda SH, Pusich B, Richter G, Landwehr P, Oliva VL, Tielbeek A, Wiesinger B, Hak JB, Tielemans H, Ziemer G, Cristea E, Lansky A, Bérégi JP. Sirolimus-eluting stents for the treatment of obstructive superficial femoral artery disease: six-month results. Circulation 2002;106(12):1505–1509
Duda SH, Bosiers M, Lammer J, Scheinert D, Zeller T, Tielbeek A, Anderson J, Wiesinger B, Tepe G, Lansky A, Mudde C, Tielemans H, Bérégi JP. Sirolimus-eluting versus bare nitinol stent for obstructive superficial femoral artery disease: The SIROCCO II trial. J Vasc Interv Radiol 2005;16(3):331–338
Scheinert D, Scheinert S, Sax J, Piorkowski C, Bräunlich S, Ulrich M, Biamino G, Schmidt A. Prevalence and clinical impact of stent fractures after femoropopliteal stenting. J Am Coll Cardiol 2005;45(2):312–315
Rits J, van Herwaarden JA, Jahrome AK, Krievins D, Moll FL. The incidence of arterial stent fractures with exclusion of coronary, aortic, and non-arterial settings. Eur J Vasc Endovasc Surg 2008;36(3):339–345
Solis J, Allaqaband S, Bajwa T. A case of popliteal stent fracture with pseudoaneurysm formation. Cathet Cardiovasc Interv 2006;67(2):319–322
Valibhoy AR, Mwipatayi BP, Sieunarine K. Fracture of a carotid stent: an unexpected complication. J Vasc Surg 2007;45(3):603–606
Knirsch W, Haas NA, Lewin MAG, Uhlemann F. Longitudinal stent fracture 11 months after implantation in the left pulmonary artery and successful management by a stent-in-stent maneuver. Cathet Cardiovasc Interv 2003;58(1):116–118
Nordmeyer J, Khambadkone S, Coats L, Schievano S, Lurz P, Parenzan G, Taylor AM, Lock JE, Bonhoeffer P. Risk stratification, systematic classification, and anticipatory management strategies for stent fracture after percutaneous pulmonary valve implantation. Circulation 2007;115(11):1392–1397
Magee AG, Brzezinska-Rajszys G, Qureshi SA, Rosenthal E, Zubrzycka M, Ksiazyk J, Tynan M. Stent implantation for aortic coarctation and recoarctation. Heart 1999;82(5):600–606
Jacobs TS, Won J, Gravereaux EC, Faries PL, Morrissey N, Teodorescu VJ, Hollier LH, Marin ML. Mechanical failure of prosthetic human implants: a 10-year experience with aortic stent graft devices. J Vasc Surg 2003;37(1):16–26
Tomizawa Y, Hanawa T, Kuroda D, Nishida H, Endo M. Corrosion of stainless steel sternal wire after long-term implantation. J Artif Organs 2006;9(1):61–66
Heintz C, Riepe G, Birken L, Kaiser E, Chakfe N, Morlock M, Delling G, Imig H. Corroded nitinol wires in explanted aortic endografts: an important mechanism of failure? J Endovasc Ther 2001;8(3):248–253
Köster R, Vieluf D, Kiehn M, Sommerauer M, Kahler J, Baldus S, Meinertz T, Hamm CW. Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis. Lancet 2000;356(9245):1895–1897
Tomizawa Y, Hanawa T. Corrosion of pure titanium sternal wire. Ann Thorac Surg 2007;84(3):1012–1014
Arita M, Omori K, Horikiri Y, Umezu M. Evaluation method for measuring an expansion force of self-expandable stent. IVR Interv Radiol 2003;18(Suppl):50–51 (in Japanese)
Umezu M, Iwasaki K, Horikiri Y, Arita M. In vivo study on the engineering evaluation of coronary stents. IVR Interv Radiol 2003;18(Suppl):48–49 (in Japanese)
Marrey RV, Burgermeister R, Grishaber RB, Ritchie RO. Fatigue and life prediction for cobalt-chromium stents: a fracture mechanics analysis. Biomaterials 2006;27:1988–2000
Robertson SW, Ritchie RO. In vitro fatigue-crack growth and fracture toughness behavior of thin-walled superelastic Nitinol tube for endovascular stents: a basis for defining the effect of crack-like defects. Biomaterials 2007;28(4):700–709
Migliavacca F, Petrini L, Massarotti P, Schievano S, Auricchio F, Dubini G. Stainless and shape memory alloy coronary stents: a computational study on the interaction with the vascular wall. Biomech Model Mechanobiol 2004;2(4):205–217
Cheng CP, Wilson NM, Hallett RL, Herfkens RJ, Taylor CA. In vivo MR angiographic quantification of axial and twisting deformations of the superficial femoral artery resulting from maximum hip and knee flexion. J Vasc Interv Radiol 2006;17(6):979–987
Nikanorov A, Smouse HB, Osman K, Bialas M, Shrivastava S, Schwartz LB. Fracture of self-expanding nitinol stents stressed in vitro under simulated intravascular conditions. J Vasc Surg 2008;48(2):435–440
Hanzawa K, Hayashi J. Failure of temporal venous filter after implantation: two cases. Ther Res 2006;27(6):1131–1135 (in Japanese)
Washio T. Two cases of nonsurgical removal of intravascular iatrogenic foreign bodies. J Kanebo Memorial Hosp 2005;21:97–99 (in Japanese)
Matsuno S. Breakage of an implantation device on loan: a case of detection of device breakage and retention in body by intraoperative radiography. J Jpn Ass Operat Room Tech 2003;24(1):55–57 (in Japanese)
Mizushima T, Ito T, Mizuno H, Udatsu Y, Miyazaki Y, Okazawa M, Kusumoto H, Nakagawa T, Masahata K, Iwase K. A case of catheter pinch-off and fracture during chemotherapy for recurrent cancer. Jpn J Surg Metabol Nutrit 2007;41:103–107 (in Japanese)
Ouaknine-Orlando B, Desruennes E, Cosset MF, De Baere T, Roche A. The pinch-off syndrome: main cause of catheter embolism. Ann Fr Anesth Reanim 1999;18(9):949–955
Hinke DH, Zandt-Stastny DA, Goodman LR, Quebbeman EJ, Krzywda EA, Andris DA. Pinch-off syndrome: a complication of implantable subclavian venous access devices. Radiology 1990;177(2):353–356
Andris DA, Krzywda EA, Schulte W, Ausman R, Quebbeman EJ. Pinch-off syndrome: a rare etiology for central venous catheter occlusion. JPEN J Parenter Enteral Nutr 1994;18(6):531–533
Mirza B, Vanek VW, Kupensky DT. Pinch-off syndrome: case report and collective review of the literature. Am Surg 2004;70(7):635–644
Fisher RG, Ferreyro R. Evaluation of current techniques for nonsurgical removal of intravascular iatrogenic foreign bodies. AJR Am J Roentgenol 1978;130(3):541–548
Reynen K. 14-year follow-up of central embolization by a guidewire. N Engl J Med 1993;329(13):970–971
Grabenwoeger F, Bardach G, Dock W, Pinterits F. Percutaneous extraction of centrally embolized foreign bodies: a report of 16 cases. Br J Radiol 1988;61(731):1014–1018
Druskin MS, Siegel PD. Bacterial contamination of indwelling intravenous polyethylene catheters. JAMA 1963;185:966–968
Savage C, Ozkan OS, Walser EM, Wang D, Zwischenberger JB. Percutaneous retrieval of chronic intravascular foreign bodies. Cardiovasc Intervent Radiol 2003;26(5):440–442
Thanigaraj S, Panneerselvam A, Yanos J. Retrieval of an IV catheter fragment from the pulmonary artery 11 years after embolization. Chest 2000;117(4):1209–1211
Ayers WB. Fatal intracardiac embolization from indwelling intravenous polyethylene catheter. AMA Arch Surg 1957;75(2):259–262
Baddour LM, Bettmann MA, Bolger AF, Epstein AE, Ferrieri P, Gerber MA, Gewitz MH, Jacobs AK, Levison ME, Newburger JW, Pallasch TJ, Wilson WR, Baltimore RS, Falace DA, Shulman ST, Tani LY, Taubert KA. Nonvalvular cardiovascular device-related infections. Circulation 2003;108(16):2015–2031
Yeo TC, Miller FA Jr, Oh JK, Freeman WK. Retained left atrial catheter: an unusual cardiac source of embolism identified by transesophageal echocardiography. J Am Soc Echocardiogr 1998;11(1):66–70
Van Den Akker-Berman LM, Pinzur S, Aydinalp A, Brezins M, Gellerman M, Elami A, Roguin N. Uneventful 25-year course of an intracardiac intravenous catheter fragment in the right heart. J Interv Cardiol 2002;15(5):421–423
Fratino G, Molinari AC, Parodi S, Longo S, Saracco P, Castagnola E, Haupt R. Central venous catheter-related complications in children with oncological/hematological diseases: an observational study of 418 devices. Ann Oncol 2005;16(4):648–654
Pezzati M, Filippi L, Chiti G, Dani C, Rossi S, Bertini G, Rubaltelli FF. Central venous catheters and cardiac tamponade in preterm infants. Intensive Care Med 2004;30(12):2253–2256
Nazareno J, Elliott JA, Finnie KJC. Cardiac arrhythmia due to subclavian catheter fracture and embolization. Can J Cardiol 2005;21(9):791–792
Uflacker R, Lima S, Melichar AC. Intravascular foreign bodies: percutaneous retrieval. Radiology 1986;160(3):731–735
Gurley JC, Booth DC, Hixson C, Smith MD. Removal of retained intracoronary percutaneous transluminal coronary angioplasty equipment by a percutaneous twin guidewire method. Cathet Cardiovasc Diagn 1990;19(4):251–256
Oda H, Soga S, Miida T, Toeda T, Higuma N. A helix of two guidewires to remove a broken guidewire trapped in the occluded coronary artery. Jpn J Interv Cardiol 1993;8:537–541 (in Japanese)
Curry JL. Recovery of detached intravascular catheter or guide wire fragments. A proposed method. Am J Roentgenol Radium Ther Nucl Med 1969;105(4):894–896
Sano A. Percutaneous retrieval of endovascular foreign bodies — experiences of Amplatz goose-neck snare. Surg Ther 1995;73:173–179 (in Japanese)
Yedlicka JW Jr, Carlson JE, Hunter DW, Castaneda-Zuniga WR, Amplatz K. Nitinol gooseneck snare for removal of foreign bodies: experimental study and clinical evaluation. Radiology 1991;178(3):691–693
Saitoh T, Ohtaki M, Matusyama M. Percutaneous intravascular removal of foreign body. Medicina 1996;33:1086–1089 (in Japanese)
Iwata Y, Koizumi J, Saitoh T. Percutaneous intravascular removal of foreign body. Jpn J Clin Radiol 2006;51:1447–1452 (in Japanese)
Kuroki K. Intravascular removal of foreign body (from the right heart). In: Kumazaki T, Nakajima Y (eds) IVR of emergency cases. Tokyo: Medical View, 2003;130–131 (in Japanese)
Ando K, Sano A, Kigami Y, Kanaoka N, Matsumoto S, Ishikura S, Okada T, Yamada K, Mayumi K, Nakatsu M, Matsusue S, Kuroda Y. Angiographic retrieval of foreign bodies in pulmonary artery: a report of three cases. Radiat Med 1993;11(2):69–74
Uda M, Sawada S, Oshima T, Kato T, Harima K, Tanaka Y. Five cases of iatrogenic foreign body in the heart and/or great vessels: retrieved percutaneously by interventional radiological technique. Jpn J Clin Radiol 1988;33:761–765 (in Japanese)
Casserly IP, Goldstein JA, Rogers JH, Lasala JM. Paradoxical embolization of a fractured guidewire: successful retrieval from left atrium using a snare device. Cathet Cardiovasc Interv 2002;57(1):34–38
Massin M, Lombet J, Rigo J. Percutaneous retrieval of a broken silastic catheter from the left atrium in a critically ill premature infant. Cathet Cardiovasc Diagn 1997;42(4):409–411
Actis Dato GM, Aidala E, Zattera GF, LeMaire SA, Wall MJ J., Mattox KL. Foreign bodies in the heart: surgical or medical therapy? Ann Thorac Surg 1999;68(1):291–292
Klucznik RP, Carrier DA, Pyka R, Haid RW. Placement of a ferromagnetic intracerebral aneurysm clip in a magnetic field with a fatal outcome. Radiology 1993;187(3):855–856
Kanal E, Shellock FG. MR imaging of patients with intracranial aneurysm clips. Radiology 1993;187(3):612–614
Dempsey MF, Condon B. Thermal injuries associated with MRI. Clin Radiol 2001;56(6):457–465
Shellock FC, Crues JV. MR procedures: biologic effects, safety, and patient care. Radiology 2004;232(3):635–652
Levine GN, Gomes AS, Arai AE, Bluemke DA, Flamm SD, Kanal E, Manning WJ, Martin ET, Smith JM, Wilke N, Shellock FS. Safety of magnetic resonance imaging in patients with cardiovascular devices: an American Heart Association scientific statement from the Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and Intervention. Circulation 2007;116(24):2878–2891
Achenbach S, Moshage W, Diem B, Bieberle T, Schibgilla V, Bachmann K. Effects of magnetic resonance imaging on cardiac pacemakers and electrodes. Am Heart J 1997;134(3):467–473
Shinbane JS, Colletti PM, Shellock FG. MR in patients with pacemakers and ICDs: defining the issues. J Cardiovasc Magn Reson 2007;9(1):5–13
National Institutes of Health (NIH) Consensus Development Program: improving medical implant performance through retrieval. http://consensus.nih.gov/2000/2000MedicalImplantsta019html.htm. Accessed August 29, 2008
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Tateishi, M., Tomizawa, Y. Intravascular foreign bodies: danger of unretrieved fragmented medical devices. J Artif Organs 12, 80–89 (2009). https://doi.org/10.1007/s10047-009-0447-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10047-009-0447-6