Skip to main content
Log in

Up to 151 days of continuous animal perfusion with trivial heparin infusion by the application of a long-term durable antithrombogenic coating to a combination of a seal-less centrifugal pump and a diffusion membrane oxygenator

  • BRIEF COMMUNICATION
  • Published:
Journal of Artificial Organs Aims and scope Submit manuscript

Abstract

We developed a new coating material (Toyobo-National Cardiovascular Center coating) for medical devices that delivers high antithrombogenicity and long-term durability. We applied this coating to an extracorporeal membrane oxygenation (ECMO) system, including the circuit tube, cannulae, a seal-less centrifugal pump, and a diffusion membrane oxygenator, to realize prolonged cardiopulmonary support with trivial anticoagulant infusion. The oxygenator consisted of a hollow-fiber membrane made of polymethylpentene, which allows the transfer of gas by diffusion through the membrane. The centrifugal pump was free of seals and had a pivot bearing. We performed a venoarterial bypass in a goat using this ECMO system, and the system was driven for 151 days with trivial anticoagulant infusion. Plasma leakage from the oxygenator did not occur and sufficient gas-exchange performance was well maintained. In the oxygenator, thrombus formation was present around the top and the distributor of the inlet portion and was very slight in the outlet portion. In the centrifugal blood pump, there was some wear in the female pivot region and quite small amounts of thrombus formation on the edge of the shroud; the pivot wear seemed to be the cause of the hemolysis observed after 20 weeks of perfusion and which resulted in the termination of the perfusion. However, no significant amounts of thrombus were observed in other parts of the system. This ECMO system showed potential for long-term cardiopulmonary support with minimal use of systemic anticoagulants.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. T Nishinaka E Tatsumi Y Taenaka N Katagiri H Ohnishi K Shioya T Fukuda M Oshikawa K Sato T Tsukiya A Homma Y Takewa H Takano M Sato S Kashiwabara H Tanaka K Sakai T Matsuda (2002) ArticleTitleAt least 34 days of animal continuous perfusion by a newly developed extracorporeal membrane oxygenation system without systemic anticoagulants Artif Organs 26 548–551 Occurrence Handle12072113 Occurrence Handle10.1046/j.1525-1594.2002.06886_3.x Occurrence Handle1:CAS:528:DC%2BD38XltlOksLg%3D

    Article  PubMed  CAS  Google Scholar 

  2. N Mendler F Podechtl G Feil P Hiltmann F Sebening (1995) ArticleTitleSeal-less centrifugal blood pump with magnetically suspended rotor: Rot-a-Flot Artif Organs 19 620–624 Occurrence Handle8572962 Occurrence Handle1:STN:280:DyaK287ntV2luw%3D%3D Occurrence Handle10.1111/j.1525-1594.1995.tb02391.x

    Article  PubMed  CAS  Google Scholar 

  3. M Sato S Kashiwabara H Tanaka E Tatsumi Y Taenaka H Takano (1999) ArticleTitleIn vitro antithrombogenic evaluation of newly developed heparinized material Jpn J Artif Organs 28 502–508

    Google Scholar 

  4. T Mizuno E Tatsumi T Nishinaka N Katagiri M Oshikawa H Naito Y Shirakawa T Tsukiya A Homma Y Takewa H Takano S Kitamura Y Taenaka (2003) ArticleTitleObservation of alveolar fibrosis in a goat following venoarterial bypass for up to 5 months using extracorporeal membrane oxygenation J Artif Organs 7 107–109

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Tomohiro Nishinaka MD.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Nishinaka, T., Tatsumi, E., Katagiri, N. et al. Up to 151 days of continuous animal perfusion with trivial heparin infusion by the application of a long-term durable antithrombogenic coating to a combination of a seal-less centrifugal pump and a diffusion membrane oxygenator. J Artif Organs 10, 240–244 (2007). https://doi.org/10.1007/s10047-007-0390-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10047-007-0390-3

Key words

Navigation