Abstract
The accuracy and uncertainty of the coulometric measurement results of reference materials for acidimetric titration were examined in this study. The results for amidosulfuric acid and potassium hydrogen phthalate are presented. The uncertainty was investigated by examining the dependency on the sample size and on the electrolysis current. Changes in the titration parameters did not result in any significant effects on the titration results. Acidimetric standards with the certified value linked to the SI were developed. In addition, the intercomparison of acidimetric standards was carried out by gravimetric titration, and the relationship between our coulometric results was determined. Furthermore, due to recent internationalization, not only the traceability to the SI but also the relationship and consistency of their analytical data have gained increasing importance. Our results were validated using certified reference materials (CRMs) obtained from different National Metrology Institutes (NMIs), and their relationships are presented.
Similar content being viewed by others
References
JIS K 8005 (2006) Reference materials for volumetric analysis, Japanese Industrial Standards Committee, Tokyo
Analytical Methods Committee (1967) Analyst 92:587–592
Breitenbach M, Eckardt E, Jansky H J, Schroder V (1988) Metrologische Abhandlungen 8:137–149
Hioki A, Kokubun A, Kubota M (1994) Analyst 119:1879–1882
Taylor JK, Smith SW (1959) J Res Nat Bur Stand, Sect A 63A:153–159
Pratt KW (1994) Anal Chim Acta 289:135–142
Yoshimori T, Tanaka T (1979) Bull Chem Soc Jpn 52:1366–1367
P. R. China Standard GB 10730-89 (1989) Primary Chemical Potassium Hydrogen Phthalate, Quality Supervision and Inspection and Quarantine, China
Yoshimori T, Hikawa I (1967) Jpn Anal 16:927–930
Mariassy M, Vyskocil L, Mathiasova A (2000) Accred Qual Assur 5:437--440
Asakai T, Minegishi R, Inaba N, Ishimura Y, Murayama M, Tanaka T (2006) Anal Sci 22:461--463
Asakai T, Kakihara Y, Kozuka Y, Hossaka S, Murayama M, Tanaka T (2006) Anal Chim Acta 567:269–276
Author information
Authors and Affiliations
Corresponding author
Additional information
Presented at -- “BERM-10” -- April 2006, Charleston, SC, USA.
Rights and permissions
About this article
Cite this article
Asakai, T., Murayama, M. & Tanaka, T. Determination of the purity of acidimetric standards by constant-current coulometry, and the intercomparison between CRMs. Accred Qual Assur 12, 151–155 (2007). https://doi.org/10.1007/s00769-006-0203-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00769-006-0203-z