Abstract
Background
In 1995, we developed a simple and safe arthroscopic technique of anterograde stable fixation of the displaced tibial eminence fractures using a cannulated screw and washer, allowing immediate mobilisation and weight bearing. Some authors described similar end results by arthroscopic fixation of this abruption with trans-osseous sutures. We proved with the biomechanical study that the fixation with strong trans-osseous sutures provides a comparable stable fixation the same as the cannulated screw and washer. We developed a test machine for cyclic loading and a machine for measuring of the pull-out strength for this study.
Methods
A standard osteotomy of the tibial spine was performed during the cadaveric biomechanical study. We performed an arthroscopic fixation with the cannulated screw and washer in ten knees, and in another group of ten knees, arthroscopic fixation was made using two trans-osseous Orthocord™ sutures. The operating time for each procedure was measured, and any possible technical complications were recorded. One thousand cycles of flexion from 0° to 90° were performed on a special loading device on all knees. The macroscopic dislocation of the fragment was measured. After the cyclic loading, all soft tissue was resected except the anterior cruciate ligament with the fixed fragment. The pull-out strength defined as translation of the tibia in anterior direction by breakage was measured with a custom-made measuring device.
Results
The average time for the screw and washer fixation was 20 min, and average time for the sutures fixation was 48 min. After cyclic loading, we did not see any dislocation of the fragment. Average pull-out strength at which fixation with a cannulated screw and washer fell was 253.42 N and mean pull-out strength at which fixation with trans-osseous sutures fell was 330.32 N. Fixation of the fragment with trans-osseous sutures was statistically significantly stronger—Wilcoxon–Mann–Whitney’s test, p = <0.00.
Conclusion
Fixation with strong trans-osseous sutures is stronger than fixation with a cannulated screw and washer on cadaveric knees. It appears that fixation with strong trans-osseous sutures allows immediate mobilisation and weight bearing like fixation with a cannulated screw and washer. Meanwhile, the time for fixation with trans-osseous sutures is significantly longer.
Similar content being viewed by others
References
Meyers MH, McKeever FM (1959) Fractures of the intercondylar eminence of the tibia. J Bone Joint Surg Am 41:209–222
Meyers MH, McKeever FM (1970) Fractures of the intercondylar eminence of the tibia. J Bone Joint Surg Am 52:1677–1683
Zariczny B (1977) Avulsion fractures of the tibial eminence treated by open reduction and pinning. J Bone Joint Surg Am 59:1111–1114
McLennan JG (1982) The role of arthroscopic surgery in the treatment of fractures of the intercondylar eminence of the tibia. J Bone Joint Surg Br 64:477–480
Lysholm J, Gillquist J (1982) Evaluation of knee ligament surgery results with special emphasis on use of a scoring scale. Am J Sports Med 10:150–154
Highgenboten CL, Jackson A, Meske NBG (1989) Genucom, KT-1000, and Stryker knee laxity measuring device comparisons. Device reproducibility and interdevice comparison in asymptomatic subjects. Am J Sports Med 17:743–746
Wroble RR, Van Ginkel LA, Grood ES, Noyes FR, Shaffer BL (1990) Repeatability of the KT-1000 arthrometer in a normal population. Am J Sports Med 18:6–9
Van Loon T, Mart RKA (1991) Fracture of the intercondylar eminence of the tibia treated by arthroscopic fixation. Arthroscopy 7:385–388
Berg EE (1993) Comminuted tibial eminence anterior cruciate ligament avulsion fractures: failure of arthroscopic treatment. Arthroscopy 9:446–450
Mathews DE, Geissler WB (1994) Arthroscopic suture fixation of displaced tibial eminence fractures. Arthroscopy 10:418–423
Carro LP, Suarez GG, Cimiano FG (1994) The arthroscopic knot technique for fracture of the tibia in children. Arthroscopy 10:698–699
Veselko M, Senekovič V, Tonin M (1996) Simple and safe arthroscopic placement and removal of cannulated screw and washer for fixation of tibial avulsion fracture of the anterior cruciate ligament. Arthroscopy 12:259–262
Kogan MG, Marks P, Amendola A (1997) Technique for arthroscopic suture fixation of displaced tibial intercondylar eminence fractures. Arthroscopy 13:301–306
Mah JY, Adili A, Otsuka NY, Ogilvie R (1998) Follow-up study of arthroscopic reduction and fixation of type III tibial eminence fractures. J Pediatr Orthop 18:475–477
Iborra JP, Mazeau P, Louahem D, Dimeglio A (1999) Fractures of the intercondylar eminence of the tibia in children. Apropos of 25 cases with a 1–20 year follow up. Rev Chir Orthop Reparatrice Appar Mot 85:563–573
Osti L, Merlo F, Liu SH, Bocchi L (2000) A simple modified arthroscopic procedure for fixation of displaced tibial eminence fractures. Arthroscopy 16:379–382
Binnet MS, Gurkan I, Ylmaz C et al (2001) Arthroscopic fixation of intercondylar eminence fractures using 4-portal technique. Arthroscopy 17:450–460
Kocher MS, Foreman ES, Micheli LJ (2003) Laxity and functional outcome after arthroscopic reduction and internal fixation of displaced tibial spine fractures in children. Arthroscopy 19:1085–1090
Senekovič V, Veselko M (2003) Anterograde arthroscopic fixation of avulsion fractures of the tibial eminence with a cannulated screw: five-year results. Arthroscopy 19:54–61
Hunter RE, Willis JA (2004) Arthroscopic fixation of avulsion fractures of the tibial eminence: technique and outcome. Arthroscopy 20:113–121
Ahn JH, Yoo JC (2005) Clinical outcome of arthroscopic reduction and suture for displaced acute and chronic tibial spine fractures. Knee Surg Sports Traumatol Arthrosc 13:116–121
Bong MR, Romero A, Kubiak E, Iesaka K, Heywood CS, Kummer F, Rosen J, Jazrawi L (2005) Suture versus screw fixation of displaced tibial eminence fractures: a biomechanical comparison. Arthroscopy 21:1172–1176
Tsukada H, Ishibashi Y, Tsuda E, Hiraga Y, Toh SA (2005) Biomechanical comparison of repair techniques for anterior cruciate ligament tibial avulsion fracture under cyclic loading. Arthroscopy 10:1197–1201
Zhao J, Huangfu X (2007) Arthroscopic treatment of nonunited anterior cruciate ligament tibial avulsion fracture with figure-of-8 suture fixation technique. Arthroscopy 23:405–410
Mahar AT, Duncan D, Oka R, Lowry A, Gillingham B, Chambers H (2008) Biomechanical comparison of four different fixation techniques for pediatric tibial eminence avulsion fractures. J Pediatr Orthop 28(2):159–162
Wilfinger C, Castellani C, Raith J, Pilhatsch A, Höllwarth ME, Weinberg AM (2009) Nonoperative treatment of tibial spine fractures in children-38 patients with a minimum follow-up of 1 year. J Orthop Trauma 23(7):519–524
Tudisco C, Giovarruscio R, Febo A, Savarese E, Bisicchia S (2010) Intercondylar eminence avulsion fracture in children: long-term follow-up of 14 cases at the end of skeletal growth. J Pediatr Orthop B 19(5):403–408
Su WR, Wang PH, Wang HN, Lin CJ (2011) A simple, modified arthroscopic suture fixation of avulsion fracture of the tibial intercondylar eminence in children. J Pediatr Orthop B 20(1):17–21
Conflict of interest
None.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Senekovic, V., Balazic, M. Bioabsorbable sutures versus screw fixation of displaced tibial eminence fractures: a biomechanical study. Eur J Orthop Surg Traumatol 24, 209–216 (2014). https://doi.org/10.1007/s00590-013-1176-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00590-013-1176-3