Skip to main content
Log in

Geometrical strengthening and tip-sharpening of a microneedle array fabricated by X-ray lithography

  • Technical paper
  • Published:
Microsystem Technologies Aims and scope Submit manuscript

Abstract

A novel fabrication method for LIGA (from the German “Lithographie”, “Galvanik”, and “Abformung”) microneedles with through holes is presented. Such microneedles are in demand by most bio-medical MEMS applications and in some fluidic MEMS applications. We propose a technique that combines conventional deep X-ray lithography, plane-pattern to cross-section transfer (PCT) process, and alignment X-ray lithography. The technique provides precise hole alignment with ± 3 μm tolerance. Finite-element simulations on various hole locations were performed to determine the optimum position. We previously fabricated a microneedle with a 100-μm base and a 300-μm height by a right-triangular mask. The resultant microneedle had a very sharp tip but was excessively steep, and thus resulted in a very low strength. Improved strength and tip sharpness was consequently achieved by changing the mask-pattern from a triangular pattern to a polygonal mask and changing the dimensions of the microneedle to have a 300-μm base with various heights between 350 and 800 μm. Using the proposed technique, we could produce a total of 100 hollow microneedles on a 5 × 5 mm2 chip. Moreover, we successfully fabricated sharpened microneedles that were stronger than that we have fabricated so far. The molding process or electroplating and the cost list of the LIGA microneedle will also be included.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10

Similar content being viewed by others

References

  • Ann B (2001) Human body. Dorling Kindersley Publishing Inc., New York

    Google Scholar 

  • Khumpuang S, Maeda R, Sugiyama S (2004) Design and fabrication of a coupled microneedle array and insertion guide array for safe penetration through skin proc. MHS’03 (Nagoya, Japan), pp 233–236

  • Griss P, Stemme G (2002) Novel, side opened out-of-plane microneedles for microfluidic transdermal interfacing proc. MEMS’02 (Las Vegas, USA), pp 467–470

  • Sugiyama S, Khumpuang S, Kawaguchi G (2004) J Micromech Microeng 14:1399–1405

    Article  Google Scholar 

  • Zahn DJ, Talbot HN, Liepmann D, Pisano PA (2000) Biomed Microdevices 4:295–302

    Article  Google Scholar 

Download references

Acknowledgment

This work was partly granted by the center of promotion for the twenty first century COE program at Ritsumeikan University, Japan

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Susumu Sugiyama.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Khumpuang, S., Horade, M., Fujioka, K. et al. Geometrical strengthening and tip-sharpening of a microneedle array fabricated by X-ray lithography. Microsyst Technol 13, 209–214 (2007). https://doi.org/10.1007/s00542-006-0173-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00542-006-0173-4

Keywords

Navigation