Skip to main content

Advertisement

Log in

Isometric strength measurement for muscle weakness in cancer patients

Reproducibility of isometric muscle strength measurements with a hand-held pull-gauge dynamometer in cancer patients

  • Original Article
  • Published:
Supportive Care in Cancer Aims and scope Submit manuscript

Abstract

Our aim was to determine several indexes of reproducibility for strength measurements with a hand-held pull-gauge dynamometer (MFB50K) in cancer patients. Two independent testers performed repeated measurements of maximal isometric elbow and knee strength. The measurements were gathered in a convenience sample of 40 patients (27 men, age 20–72 years) with various types and stages of cancer. These patients were recruited from the medical oncology clinic of a university hospital. The Pearson product moment correlation coefficient, the intraclass correlation coefficient (ICC), the standard error of measurement (SEM) and its associated 95% confidence interval, the smallest detectable difference (SDD) and the limits of agreement were determined as outcome measures for reproducibility. The results for the Pearson product moment correlation and the ICC were 0.90 for elbow and 0.96 for knee extension strength. The results in terms of the SDDs were 29.4 newton (N) for elbow and 54.8 N for knee strength. The limits of agreement for elbow strength were –21.7 N and 38.5 N (mean 8.4 N). For knee strength the limits of agreement were –49.8 N and 59.8 N (mean 5 N). The Pearson product moment correlation and the ICC suggested good reproducibility. However, the more informative indices of reproducibility, i.e. the SEM and the SDD, showed relatively large measurement error between the testers. Therefore, the current use of the MFB50K for the measurement of muscle strength is not supported in cancer patients.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Knols, R.H., Stappaerts, K.H., Fransen, J. et al. Isometric strength measurement for muscle weakness in cancer patients. Support Care Cancer 10, 430–438 (2002). https://doi.org/10.1007/s00520-002-0343-6

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00520-002-0343-6

Navigation