Abstract
Background
The role of the lacrimal sac (LS) and the medial canthal tendon in the lacrimal pump mechanism is controversial. This study used ultrasonic visualization to analyze this phenomenon.
Methods
Movements of the LS and the medial canthal tendon during blinking were visualized with sonography. In addition, the maximal profile area of the LS was measured before and after blinking using 15-MHz sonography in 14 individuals with a normal lacrimal drainage system and in six patients with lacrimal duct obstruction.
Results
The upper part of the LS could be located as an echolucent structure between the lacrimal bone and the medial canthal tendon. The medial canthal tendon appeared to compress the LS during lid closure and release the LS during lid opening. The measured profile area of the visible normal LS at the compression time decreased by 50%. The dilated LS of patients with obstruction could also be compressed by the orbital muscle on blinking, but the maximum area decrease was only 15.5%.
Conclusion
The findings imply that the lacrimal part of the orbicularis muscle contracts during blinking, with the medial canthal tendon compressing the LS in a cranial direction. Completion of lid closure then compresses both canaliculi and LS, forcing the intrasacral fluid through the drainage system. The expansion of the LS during the opening phase of the blink causes suction, and after opening of the punctal areas the canaliculi and LS vacuum breaks to reload with tear fluid. These findings demonstrate the importance of the orbicularis muscle and the medial canthal tendon for the lacrimal pump mechanism during blinking.
Similar content being viewed by others
References
Ayub M, Thale AB, Hedderich J, Tillmann BN, Paulsen FP (2003) The cavernous body of the human efferent tear ducts contributes to regulation of tear outflow. Invest Ophthalmol Vis Sci 44(11):4900–4907
Becker B (1992) Tricompartment model of the lacrimal pump mechanism. Ophthalmology 99(7):1139–1145
Doane MG (1981) Blinking and the mechanics of the lacrimal drainage system. Ophthalmology 88(8):844–851
Dutton JJ (1989) Standardized echography in the diagnosis of lacrimal drainage dysfunction. Arch Ophthalmol 107(7):1010–1012
Glatt HJ, Chan AC, Barrett L (1991) Evaluation of dacryocystorhinostomy failure with computed tomography and computed tomographic dacryocystography. Am J Ophthalmol 112(4):431–436
Tränenapparet HJ (1866) Handbuch der Eingeweidelehre des Menschen. Viehweg, Braunschweig, pp 707–715
Jones LT (1957) Epiphora. II. Its relation to the anatomic structures and surgery of the medial canthal region. Am J Ophthalmol 43(2):203–212
Jones LT (1973) Anatomy of the tear system. Int Ophthalmol Clin 13(1):3–22
Linberg JV, McCormick SA (2002) Primary acquired nasolacrimal duct obstruction. A clinicopathologic report and biopsy technique. Ophthalmology 93(8):1055–1063
Lloyd GA, Jones BR, Welham RA (1972) Intubation macrodacryocystography. Br J Ophthalmol 56(8):600–603
Maurice DM (1973) The dynamics and drainage of tears. Int Ophthalmol Clin 13(1):103–116
Mauriello JA Jr, Palydowycz S, DeLuca J (1992) Clinicopathologic study of lacrimal sac and nasal mucosa in 44 patients with complete acquired nasolacrimal duct obstruction. Ophthalmic Plast Reconstr Surg 8(1):13–21
Montanara A, Mannino G, Contestabile MT (1983) Macrodacryocystography and echography in diagnosis of disorders of the lacrimal system. Surv Ophthalmol 28(1):33–41
Nagashima K, Araki K (1963) On the lacrimal part of the orbicularis muscles with special reference to the sac dilators. Jpn J Ophthalmol 7:220–225
Oksala A (1959) Diagnosis by ultrasound in acute dacryocystitis. Acta Ophthalmol (Copenh) 37(2):176–179
Paulsen F, Hallmann U, Paulsen J, Thale A (2000) Innervation of the cavernous body of the human efferent tear ducts in tear outflow mechanism. J Anat 197 (Pt 2):177–187
Paulsen FP, Hinz M, Schaudig U, Thale AB, Hoffmann W (2002) TFF peptides in the human efferent tear ducts. Invest Ophthalmol Vis Sci 43(11):3359–3364
Paulsen F, Corfield A, Hinz M, Hoffmann W, Schaudig U, Thale A, Berry M (2004) Tear outflow. Impact of mucins and TFF-peptides. Ophthalmologe 101(1):19–24
Rochels R, Lieb W, Nover A (1984) Echographic diagnosis in diseases of the efferent tear ducts. Klin Monatsbl Augenheilkd 185(4):243–249
Rosengren B (1972) On lacrimal drainage. Ophthalmologica 164(6):409–421
Rossomondo RM, Carlton WH, Trueblood JH, Thomas RP (1972) A new method of evaluating lacrimal drainage. Arch Ophthalmol 88(5):523–525
Rubin PA, Bilyk JR, Shore JW, Sutula FC, Cheng HM (1994) Magnetic resonance imaging of the lacrimal drainage system. Ophthalmology 101(2):235–243
Sahlin S, Chen E (1996) Evaluation of the lacrimal drainage function with the drop test. Am J Ophthalmol 122(5):701–708
Schirmer O (1903) Studien zur Physiologie und Pathologie der Tränenabsonderung und Tränenabfuhr. Albrecht Von Graefes Arch Klin Exp Ophthalmol 56:197–212
Thale A, Paulsen F, Rochels R, Tillmann B (1998) Functional anatomy of the human efferent tear ducts: a new theory of tear outflow mechanism. Graefes Arch Clin Exp Ophthalmol 236(9):674–678
Tost F, Bruder R, Clemens S (2002) 20-MHz ultrasound of pre-saccular lacrimal ducts. Ophthalmologe 99(1):25–28
White WL, Glover AT, Buckner AB (1991) Effect of blinking on tear elimination as evaluated by dacryoscintigraphy. Ophthalmology 98(3):367–369
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Pavlidis, M., Stupp, T., Grenzebach, U. et al. Ultrasonic visualization of the effect of blinking on the lacrimal pump mechanism. Graefe's Arch Clin Exp Ophthalmol 243, 228–234 (2005). https://doi.org/10.1007/s00417-004-1033-5
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00417-004-1033-5