Abstract
Background
Large acetabular defects and pelvic discontinuity represent complex problems in revision total hip arthroplasty. This study aimed to investigate whether reconstruction with the Ganz reinforcement ring would provide durable function in large acetabular defects.
Patients and methods
46 hips (45 patients, 19 male, 26 female, mean age 68 years) with AAOS type III and IV defects undergoing acetabular revision with the Ganz reinforcement ring were evaluated at a mean follow-up of 74 months (24–161 months). Fourteen patients died during follow-up. All surviving patients were available for clinical assessment and radiographic studies. Radiographs were evaluated for bone healing and component loosening. A Cox-regression model was performed to identify factors influencing survival of the Ganz-ring.
Results
In the group of AAOS III defects, 3 of 26 acetabular reconstructions failed, all due to aseptic loosening. In pelvic discontinuity (AAOS IV), 9 of 20 hips failed due to aseptic loosening (n = 4), deep infection (n = 3), and non-union of the pelvic ring (n = 2). With acetabular revision for any reason as an endpoint, the estimated Kaplan–Meier 5-year survival was 86% in type III defects and 57% in type IV defects, respectively. The presence of pelvic discontinuity was identified as the only independent predictive factor for failure of the Ganz ring acetabular reconstruction (AAOS III vs. IV, Hazard ratio: 0.217, 95%, Confidence interval: 0.054–0.880, p = 0.032).
Conclusion
The Ganz reinforcement ring remains a favorable implant for combined segmental and cavitary defects. However, defects with pelvic discontinuity demonstrate high failure rates. The indications should therefore be narrowed to acetabular defects not associated with pelvic discontinuity.
Similar content being viewed by others
Change history
19 December 2018
The author would like to correct the errors in the publication of the original article. The corrected details are given below for your reading.
19 December 2018
The author would like to correct the errors in the publication of the original article. The corrected details are given below for your reading.
References
Abolghasemian M, Tangsataporn S, Sternheim A, Backstein D, Safir O, Gross AE (2013) Combined trabecular metal acetabular shell and augment for acetabular revision with substantial bone loss: a mid-term review. Bone Jt J 95-B(2):166–172
Abolghasemian M, Sadeghi Naini M, Tangsataporn S, Lee P, Backstein D, Safir O et al (2014) Reconstruction of massive uncontained acetabular defects using allograft with cage or ring reinforcement: an assessment of the graft’s ability to restore bone stock and its impact on the outcome of re-revision. Bone Jt J 96-B(3):319–324
Abolghasemian M, Tangsaraporn S, Drexler M, Barbuto R, Backstein D, Safir O et al (2014) The challenge of pelvic discontinuity: cup-cage reconstruction does better than conventional cages in mid-term. Bone Jt J 96-B(2):195–200
Amenabar T, Rahman WA, Hetaimish BM, Kuzyk PR, Safir OA, Gross AE (2016) Promising mid-term results with a cup-cage construct for large acetabular defects and pelvic discontinuity. Clin Orthop Relat Res 474(2):408–414
Berasi CC, Berend KR, Adams JB, Ruh EL, Lombardi AV Jr (2015) Are custom triflange acetabular components effective for reconstruction of catastrophic bone loss? Clin Orthop Relat Res 473(2):528–535
Berry DJ, Muller ME (1992) Revision arthroplasty using an anti-protrusio cage for massive acetabular bone deficiency. J Bone Jt Surg Br 74(5):711–715
Berry DJ, Lewallen DG, Hanssen AD, Cabanela ME (1999) Pelvic discontinuity in revision total hip arthroplasty. J Bone Jt Surg Am 81(12):1692–1702
Brown NM, Hellman M, Haughom BH, Shah RP, Sporer SM, Paprosky WG (2014) Acetabular distraction: an alternative approach to pelvic discontinuity in failed total hip replacement. Bone Jt J 96-B(11 Supple A):73–77
Christie MJ, Barrington SA, Brinson MF, Ruhling ME, DeBoer DK (2001) Bridging massive acetabular defects with the triflange cup: 2- to 9-year results. Clin Orthop Relat Res 393:216–227
D’Antonio JA, Capello WN, Borden LS, Bargar WL, Bierbaum BF, Boettcher WG et al (1989) Classification and management of acetabular abnormalities in total hip arthroplasty. Clin Orthop Relat Res 243:126–137
DeBoer DK, Christie MJ, Brinson MF, Morrison JC (2007) Revision total hip arthroplasty for pelvic discontinuity. J Bone Jt Surg Am 89(4):835–840
Eggli S, Muller C, Ganz R (2002) Revision surgery in pelvic discontinuity: an analysis of seven patients. Clin Orthop Relat Res 398:136–145
Friedrich MJ, Schmolders J, Michel RD, Randau TM, Wimmer MD, Kohlhof H et al (2014) Management of severe periacetabular bone loss combined with pelvic discontinuity in revision hip arthroplasty. Int Orthop 38(12):2455–2461
Gerber A, Pisan M, Zurakowski D, Isler B (2003) Ganz reinforcement ring for reconstruction of acetabular defects in revision total hip arthroplasty. J Bone Jt Surg Am 85-A(12):2358–2364
Gill TJ, Sledge JB, Muller ME (1998) The Burch-Schneider anti-protrusio cage in revision total hip arthroplasty: indications, principles and long-term results. J Bone Jt Surg Br 80(6):946–953
Goodman S, Saastamoinen H, Shasha N, Gross A (2004) Complications of ilioischial reconstruction rings in revision total hip arthroplasty. J Arthroplast 19(4):436–446
Grappiolo G, Loppini M, Longo UG, Traverso F, Mazziotta G, Denaro V (2015) Trabecular metal augments for the management of Paprosky type III defects without pelvic discontinuity. J Arthroplast 30(6):1024–1029
Issack PS, Nousiainen M, Beksac B, Helfet DL, Sculco TP, Buly RL (2009) Acetabular component revision in total hip arthroplasty. Part II: management of major bone loss and pelvic discontinuity. Am J Orthop (Belle Mead NJ) 38(11):550–556
Kmiec K, Dorman T, Andrzej G, Synder M, Kozlowski P, Sibinski M (2015) Early results of revision acetabular cup using antiprotrusio reconstruction rings and allografts. Indian J Orthop 49(3):317–322
Kokubo Y, Oki H, Sugita D, Negoro K, Takeno K, Miyazaki T et al (2016) Long-term clinical outcome of acetabular cup revision surgery: comparison of cemented cups, cementless cups, and cemented cups with reinforcement devices. Eur J Orthop Surg Traumatol 26(4):407–413
Kosashvili Y, Backstein D, Safir O, Lakstein D, Gross AE (2009) Acetabular revision using an anti-protrusion (ilio-ischial) cage and trabecular metal acetabular component for severe acetabular bone loss associated with pelvic discontinuity. J Bone Jt Surg Br 91(7):870–876
Makinen TJ, Fichman SG, Watts E, Kuzyk PR, Safir OA, Gross AE (2016) The role of cages in the management of severe acetabular bone defects at revision arthroplasty. Bone Jt J 98-B(1 Suppl A):73–77
Philippe R, Gosselin O, Sedaghatian J, Dezaly C, Roche O, Sirveaux F et al (2012) Acetabular reconstruction using morselized allograft and a reinforcement ring for revision arthroplasty with Paprosky type II and III bone loss: survival analysis of 95 hips after 5 to 13 years. Orthop Traumatol Surg Res 98(2):129–137
Regis D, Sandri A, Bonetti I, Bortolami O, Bartolozzi P (2012) A minimum of 10-year follow-up of the Burch-Schneider cage and bulk allografts for the revision of pelvic discontinuity. J Arthroplasty 27(6):1057–1063e1
Schlegel UJ, Bitsch RG, Pritsch M, Clauss M, Mau H, Breusch SJ (2006) Mueller reinforcement rings in acetabular revision: outcome in 164 hips followed for 2-17 years. Acta Orthop 77(2):234–241
Schlegel UJ, Bitsch RG, Pritsch M, Aldinger PR, Mau H, Breusch SJ (2008) Acetabular reinforcement rings in revision total hip arthroplasty: midterm results in 298 cases. Orthopade 37(9):904, 906–913
Schmolders J, Friedrich MJ, Michel RD, Randau TM, Wimmer MD, Strauss AC et al (2015) Acetabular defect reconstruction in revision hip arthroplasty with a modular revision system and biological defect augmentation. Int Orthop 39(4):623–630
Schreurs BW, Gardeniers JW, Slooff TJ (2001) Acetabular reconstruction with bone impaction grafting: 20 years of experience. Instr Course Lect 50:221–228
Sheth NP, Melnic CM, Paprosky WG (2014) Acetabular distraction: an alternative for severe acetabular bone loss and chronic pelvic discontinuity. Bone Jt J 96-B(11 Supple A):36–42
Siebenrock KA, Tannast M, Kim S, Morgenstern W, Ganz R (2005) Acetabular reconstruction using a roof reinforcement ring with hook for total hip arthroplasty in developmental dysplasia of the hip-osteoarthritis minimum 10-year follow-up results. J Arthroplast 20(4):492–498
Siegmeth A, Duncan CP, Masri BA, Kim WY, Garbuz DS (2009) Modular tantalum augments for acetabular defects in revision hip arthroplasty. Clin Orthop Relat Res 467(1):199–205
Sporer SM, Bottros JJ, Hulst JB, Kancherla VK, Moric M, Paprosky WG (2012) Acetabular distraction: an alternative for severe defects with chronic pelvic discontinuity? Clin Orthop Relat Res 470(11):3156–3163
Steno B, Kokavec M, Necas L (2015) Acetabular revision arthroplasty using trabecular titanium implants. Int Orthop 39(3):389–395
Taunton MJ, Fehring TK, Edwards P, Bernasek T, Holt GE, Christie MJ (2012) Pelvic discontinuity treated with custom triflange component: a reliable option. Clin Orthop Relat Res 470(2):428–434
Whitehouse MR, Masri BA, Duncan CP, Garbuz DS (2015) Continued good results with modular trabecular metal augments for acetabular defects in hip arthroplasty at 7 to 11 years. Clin Orthop Relat Res 473(2):521–527
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Funding
There is no funding source.
Ethical approval
This article does not contain any studies with human participants or animals performed by any of the authors.
Informed consent
Informed consent was obtained from all individual participants included in the study.
Rights and permissions
About this article
Cite this article
Hourscht, C., Abdelnasser, M.K., Ahmad, S.S. et al. Reconstruction of AAOS type III and IV acetabular defects with the Ganz reinforcement ring: high failure in pelvic discontinuity. Arch Orthop Trauma Surg 137, 1139–1148 (2017). https://doi.org/10.1007/s00402-017-2731-x
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00402-017-2731-x