Abstract
Aim
One main goal in primary total hip replacement is the reconstruction of preoperative biomechanical conditions by adequate implant positioning. Our aim was to compare the planned and effectively implanted stem position in using a program for digital migration measurement.
Patients
We examined 120 cases with this new method based on a modification of the EBRA-FCA program and compared these results to direct plain radiographic methods. In addition, the intra- and inter-observer reliability was determined in 50 cases.
Results
We observed a rate of correct prediction of 80% for the size of the stem. The new method revealed a good correlation (0.95 and 0.64 for the position along the stem axis and 0.84 for the stem angle) to direct plain radiographic methods. Regarding the intraclass correlation coefficient for intra- and inter-observer reliability, the results were superior (0.97 vs. 0.81–0.84 and 0.90 vs. 0.74–0.88) compared with direct plain radiographic methods.
Conclusion
We concluded that the comparison of the planned and implanted stem position using a modified EBRA-FCA method is more reproducible than direct radiographic measurements.
Similar content being viewed by others
References
Muller ME (1992) Lessons of 30 years of total hip arthroplasty. Clin Orthop 274:12–21
Bono JV (2004) Digital templating in total hip arthroplasty. J Bone Joint Surg Am 86-A:118–122
Eggli S, Pisan M, Muller ME (1998) The value of preoperative planning for total hip arthroplasty. J Bone Joint Surg Br 80-B:382–390
Rubash HE, Parvataneni HK (2007) The pants too short, the leg too long: leg length inequality after THA. Orthopedics 30(9):764–765
Asayama I, Chamnongkich S, Simpson KJ, Kinsey TL, Mahoney OM (2005) Reconstructed hip joint position and abductor muscle strength after total hip arthroplasty. J Arthroplasty 20(4):414–420
Crooijmans HJ, Laumen AM, van Pul C, van Mourik JB (2009) A new digital preoperative planning method for total hip arthroplasties. Clin Orthop Relat Res 467(4):909–916
Gonzalez Della Valle A, Padgett DE, Salvati EA (2005) Preoperative planning for primary total hip arthroplasty. J Am Acad Orthop Surg 13:455
González Della Valle A, Slullitel G, Piccaluga F, Salvati EA (2005) The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty. J Arthroplasty 20(1):51–58
Iorio R, Siegel J, Specht LM, Tilzey JF, Hartman A, Healy WL (2009) A comparison of acetate vs digital templating for preoperative planning of total hip arthroplasty: is digital templating accurate and safe? J Arthroplasty 24(2):175–179
The B, Verdonschot N, van Horn JR, van Ooijen PM, Diercks RL (2007) Digital versus analogue preoperative planning of total hip arthroplasties: a randomized clinical trial of 210 total hip arthroplasties. J Arthroplasty 22(6):866–870
Carter LW, Stovall DO, Young TR (1995) Determination of accuracy of preoperative templating of noncemented femoral prostheses. J Arthroplasty 10:507–513
Davila JA, Kransdorf MJ, Duffy GP (2006) Surgical planning of total hip arthroplasty: accuracy of computer-assisted EndoMap software in predicting component size. Skeletal Radiol 35(6):390–393
Kumar PG, Kirmani SJ, Humberg H, Kavarthapu V, Li P (2009) Reproducibility and accuracy of templating uncemented THA with digital radiographic and digital TraumaCad templating software. Orthopedics 32(11):815
Khanduja V, Tek V, Scott G (2006) The effect of a neck-retaining femoral implant on leg-length inequality following total hip arthroplasty: a radiological study. J Bone Joint Surg Br 88(6):712–715
Suh KT, Cheon SJ, Kim DW (2004) Comparison of preoperative templating with postoperative assessment in cementless total hip arthroplasty. Acta Orthop Scand 75:40–44
Malchau H, Karrholm J, WangYX HerbertsP (1995) Accuracy of migration analysis in hip arthroplasty: digitised and conventional radiography, compared to radiostereometry in 51 patients. Acta Orthop Scand 66:418
Sutherland CJ, Wilde AH, Borden LS, Marks KE (1982) A ten-year follow-up of one hundred consecutive Muller curved-stem total hip-replacement arthroplasties. J Bone Joint Surg Am 64:970
Krismer M, Bauer R, Tschupik J, Mayrhofer P (1995) EBRA: a method to measure migration of acetabular components. J Biomech 28:1225
Krismer M, Biedermann R, Stöckl B, Fischer M, Bauer R, Haid C (1999) The prediction of failure of the stem in THR by measurement of early migration using EBRA-FCA. J Bone Joint Surg Br 81:273
Biedermann R, Krismer M, Stockl B, Mayrhofer P, Ornstein E, Franzen H (1999) Accuracy of EBRA-FCA in the measurement of migration of femoral components of total hip replacement. J Bone Joint Surg Br 81:266
Phillips NJ, Stockley I, Wilkinson JM (2002) Direct plain radiographic methods versus EBRA-Digital for measuring implant migration after total hip arthroplasty. J Arthroplasty 17(7):917–925
Franken M, Grimm B, Heyligers I (2010) A comparison of four systems for calibration when templating for total hip replacement with digital radiography. J Bone Joint Surg Br 92(1):136–141
Hardinge K (1982) The direct lateral approach to the hip. J Bone Joint Surg Br 64(1):17–19
Hamadouche M, Witvoet J, Porcher R, Meunier A, Sedel L, Nizard R (2001) Hydroxyapatite-coated versus grit-blasted femoral stems. A prospective, randomised study using EBRA-FCA. J Bone Joint Surg Br 83(7):979–987
Kroell A, Beaulé P, Krismer M, Behensky H, Stoeckl B, Biedermann R (2009) Aseptic stem loosening in primary THA: migration analysis of cemented and cementless fixation. Int Orthop 33(6):1501–1505
Wedemeyer C, Quitmann H, Xu J, Heep H, von Knoch M, Saxler G (2008) Digital templating in total hip arthroplasty with the Mayo stem. Arch Orthop Trauma Surg 128(10):1023–1029
Wilkinson JM, Hamer AJ, Elson RA, Stockley I, Eastell R (2002) Precision of EBRA-Digital software for monitoring implant migration after total hip arthroplasty. J Arthroplasty 17(7):910–916
Naito M, Ogata K, Asayama I (1999) Intraoperative limb length measurement in total hip arthroplasty. Int Orthop 23:31
Sarin VK, Pratt WR, Bradley GW (2005) Accurate femur repositioning is critical during intraoperative total hip arthroplasty length and offset assessment. J Arthroplasty 20(7):887–891
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Fottner, A., Steinbrück, A., Sadoghi, P. et al. Digital comparison of planned and implanted stem position in total hip replacement using a program form migration analysis. Arch Orthop Trauma Surg 131, 1013–1019 (2011). https://doi.org/10.1007/s00402-010-1256-3
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00402-010-1256-3