Skip to main content
Log in

Degeneration and regeneration in rabbit peripheral nerve with long-term nerve cuff electrode implant: a stereological study of myelinated and unmyelinated axons

  • Regular paper
  • Published:
Acta Neuropathologica Aims and scope Submit manuscript

Abstract

Selective and dynamically co-ordinated functional electrical stimulation (FES) of paralysed/paretic limbs in upper motor neuron lesioned people depends on optimal contact at the neural interface. Implanted nerve cuff electrodes may form a stable electrical neural interface, but may also inflict nerve damage. In this study the immediate and long-term effects of cuff implantation on the number and sizes of myelinated and unmyelinated axons have been evaluated with unbiased stereological techniques. Cuff electrodes were implanted in rabbit tibial nerves just below the knee joint, and the stereological analyses were carried out 2 weeks and 16 months after implantation. Myelinated axons were analysed at standardised levels proximal to, underneath, and distal to the cuff; unmyelinated axons underneath the cuff. A 27% loss of myelinated axons was found underneath and distal to the nerve cuff 2 weeks post surgery. All axonal sizes were equally lost except for the very smallest. At 16 months post surgery the number of myelinated axons was restored to control values at both levels. Except for the presence of regenerative sprouts at 2 weeks post surgery, no changes in the number or sizes of unmyelinated axons were revealed at either 2 weeks or 16 months post surgery. Our study demonstrates that implanted cuff electrodes may cause an initial loss of myelinated axons but with subsequent regeneration.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 19 September 1997 / Revised: 27 February 1998 / Revised, accepted: 31 March 1998

Rights and permissions

Reprints and permissions

About this article

Cite this article

Larsen, J., Thomsen, M., Haugland, M. et al. Degeneration and regeneration in rabbit peripheral nerve with long-term nerve cuff electrode implant: a stereological study of myelinated and unmyelinated axons. Acta Neuropathol 96, 365–378 (1998). https://doi.org/10.1007/s004010050907

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s004010050907

Navigation