Skip to main content

Advertisement

Log in

Whole-body three-dimensional contrast-enhanced magnetic resonance (MR) angiography with parallel imaging techniques on a multichannel MR system for the detection of various systemic arterial diseases

  • GRAPHIC REPORT
  • Published:
Heart and Vessels Aims and scope Submit manuscript

Abstract

Using a 1.5-T magnetic resonance (MR) imager equipped with 32 receiving channels and integrated parallel acquisition techniques, 37 patients underwent whole-body three-dimensional (3D) contrast-enhanced MR angiography (WB 3D CE MRA). The patients included had clinically documented or suspected peripheral arterial occlusive disease (PAOD, n = 19), Takayasu arteritis (n = 8), polyarteritis nodosa (n = 1), type-B dissection (n = 4), thoracic and/or abdominal aneurysm (n = 5). Sixty-eight surface coils were employed to encompass the whole body. Four 3D CE MRA stations were acquired successively through automatic table moving. The spatial resolution was 1.6 × 1.0 mm and slice thickness was 1.5 mm for all stations. A total scan range of 188 cm was acquired. Overall image quality of each arterial segment and venous overlay were assessed. The depiction of various systemic arterial diseases was evaluated and compared, in 20 patients, with other imaging modalities. This WB 3D CE MRA yielded a detailed display of the arterial system with an average MR room time of 17.4 min. The image quality was considered diagnostic in 99.3% of the arterial segments. In 7 of 19 patients with PAOD, WB MRA showed additional vascular narrowing apart from peripheral arterial disease. In nine patients with vasculitis, WB MRA depicted luminal irregularity, narrowing or occlusion, aneurysm, and collateral circulation involving multiple vascular segments. WB MRA also clearly revealed the severity and extent of dissection and aortic aneurysm. In 20 cases where additional imaging investigations have been carried out, the vascular pathologies demonstrated by WB MRA agree with these additional imaging investigations.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. FM Vogt M Goyen JF Debatin (2003) ArticleTitleMR angiography of the chest Radiol Clin North Am 41 29–41 Occurrence Handle12630683 Occurrence Handle10.1016/S0033-8389(02)00061-1

    Article  PubMed  Google Scholar 

  2. VB Ho WR Corse (2003) ArticleTitleMR angiography of the abdominal aorta and peripheral vessels Radiol Clin North Am 41 115–144 Occurrence Handle12630689 Occurrence Handle10.1016/S0033-8389(02)00062-3

    Article  PubMed  Google Scholar 

  3. SG Ruehm M Goyen J Barkhausen K Kroger S Bosky ME Ladd JF Debatin (2001) ArticleTitleRapid magnetic resonance angiography for detection of atherosclerosis Lancet 357 1086–1091 Occurrence Handle11297960 Occurrence Handle1:STN:280:DC%2BD3M3jslyrug%3D%3D Occurrence Handle10.1016/S0140-6736(00)04261-6

    Article  PubMed  CAS  Google Scholar 

  4. M Goyen HH Quick JF Debatin ME Ladd J Barhausen CU Herborn S Bosk H Kuehl M Schleputz SG Ruehm (2002) ArticleTitleWhole-body three-dimensional MR angiography with a rolling table platform: initial clinical experience Radiology 224 270–277 Occurrence Handle12091695

    PubMed  Google Scholar 

  5. M Goyen CU Herborn K Kroger TC Lauenstein JF Debatin SG Reuhm (2003) ArticleTitleDetection of atherosclerosis: systemic imaging for systemic disease with whole-body three-dimensional MR angiography: initial experience Radiology 227 277–282 Occurrence Handle12601197

    PubMed  Google Scholar 

  6. DG Kruger SJ Riederer RC Grimm PJ Rossman (2002) ArticleTitleContinuously moving table data acquisition method for long FOV contrast-enhanced MRA and whole-body MRI Magn Reson Med 47 224–231 Occurrence Handle11810664 Occurrence Handle10.1002/mrm.10061

    Article  PubMed  Google Scholar 

  7. CU Herborn M Goyen HH Quick S Bosk S Massing K Kroeger D Stoesser SG Ruehm JF Debatin (2004) ArticleTitleWhole-body 3D MR angiography of patients with peripheral arterial occlusive disease Am J Roentgenol 182 1427–1434

    Google Scholar 

  8. M Fenchel M Requardt K Tomaschko U Kramer NI Stauder T Naegele HP Schlemmer CD Claussen S Miller (2005) ArticleTitleWhole-body MR angiography using a novel 32-receiving-channel MR system with surface coil technology: first clinical experience J Magn Reson Imaging 21 596–603 Occurrence Handle15834920 Occurrence Handle10.1002/jmri.20303

    Article  PubMed  Google Scholar 

  9. H Kramer SO Schoenberg K Nikolaou A Huber A Struwe E Winnik BJ Wintersperger O Dietrich B Kiefer MF Reiser (2005) ArticleTitleCardiovascular screening with parallel imaging techniques and a whole-body MR imager Radiology 236 300–310 Occurrence Handle15987982

    PubMed  Google Scholar 

  10. M Goyen CU Herborn K Kroger SG Reuhm JF Debatin (2006) ArticleTitleTotal-body 3D magnetic resonance angiography influences the management of patients with peripheral arterial occlusive disease Eur Radiol 16 685–691 Occurrence Handle16175353 Occurrence Handle10.1007/s00330-005-0001-8

    Article  PubMed  Google Scholar 

  11. Q Chen CV Quijano VM Mai SK Krishnamoorthy W Li P Storey RR Edelman (2004) ArticleTitleOn improving temporal and spatial resolution of 3D contrast-enhanced body MR angiography with parallel imaging Radiology 231 893–899 Occurrence Handle15163824

    PubMed  Google Scholar 

  12. MA Griswold PM Jakob RM Heidemann M Nittka V Jellus J Wang B Kiefer A Haase (2002) ArticleTitleGeneralized autocalibration partially parallel acquisitions (GRAPPA) Magn Reson Med 47 1202–1210 Occurrence Handle12111967 Occurrence Handle10.1002/mrm.10171

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jiang Lin.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lin, J., Chen, B., Wang, JH. et al. Whole-body three-dimensional contrast-enhanced magnetic resonance (MR) angiography with parallel imaging techniques on a multichannel MR system for the detection of various systemic arterial diseases. Heart Vessels 21, 395–398 (2006). https://doi.org/10.1007/s00380-006-0918-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00380-006-0918-0

Key words

Navigation