Adrenal gland volume measurement in septic shock and control patients: a pilot study

  • Emergency Radiology
  • Published:
European Radiology Aims and scope Submit manuscript

Abstract

Objectives:

To compare adrenal gland volume in septic shock patients and control patients by using semi-automated volumetry.

Methods:

Adrenal gland volume and its inter-observer variability were measured with tomodensitometry using semi-automated software in 104 septic shock patients and in 40 control patients. The volumes of control and septic shock patients were compared and the relationship between volume and outcome in intensive care was studied.

Results:

The mean total volume of both adrenal glands was 7.2 ± 2.0 cm3 in control subjects and 13.3 ± 4.7 cm3 for total adrenal gland volume in septic shock patients (p < 0.0001). Measurement reproducibility was excellent with a concordance correlation coefficient value of 0.87. The increasing adrenal gland volume was associated with a higher rate of survival in intensive care.

Conclusion:

The present study reports that with semi-automated software, adrenal gland volume can be measured easily and reproducibly. Adrenal gland volume was found to be nearly double in sepsis compared with control patients. The absence of increased volume during sepsis would appear to be associated with a higher rate of mortality and may represent a prognosis factor which may help the clinician to guide their strategy.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

References

  1. Rouviere H (1932) Anatomie humaine descriptive et topographique. Masson, Paris

  2. Amsterdam JD, Marinelli DL, Arger P, Winokur A (1987) Assessment of adrenal gland volume by computed tomography in depressed patients and healthy volunteers: a pilot study. Psychiatry Res 21:189–197

    Article  CAS  PubMed  Google Scholar 

  3. Rubin RT, Phillips JJ (1991) Adrenal gland volume determination by computed tomography and magnetic resonance imaging in normal subjects. Invest Radiol 26:465–469

    Article  CAS  PubMed  Google Scholar 

  4. Farraher SW, Jara H, Chang KJ, Hou A, Soto JA (2005) Liver and spleen volumetry with quantitative MR imaging and dual-space clustering segmentation. Radiology 237:322–328

    Article  PubMed  Google Scholar 

  5. Hiroshige S, Shimada M, Harada N et al (2003) Accurate preoperative estimation of liver-graft volumetry using three-dimensional computed tomography. Transplantation 75:1561–1564

    Article  PubMed  Google Scholar 

  6. Hoshida Y, Shiratori Y, Koike Y et al (2002) Hepatic volumetry to predict adverse events in percutaneous ablation of hepatocellular carcinoma. Hepatogastroenterology 49:451–455

    PubMed  Google Scholar 

  7. Nakayama Y, Li Q, Katsuragawa S et al (2006) Automated hepatic volumetry for living related liver transplantation at multisection CT. Radiology 240

  8. Schiano TD, Bodian C, Schwartz ME, Glajchen N, Min AD (2000) Accuracy and significance of computed tomographic scan assessment of hepatic volume in patients undergoing liver transplantation. Transplantation 69:545–550

    Article  CAS  PubMed  Google Scholar 

  9. Vauthey JN, Chaoui A, Do KA et al (2000) Standardized measurement of the future liver remnant prior to extended liver resection: methodology and clinical associations. Surgery 127:512–519

    Article  CAS  PubMed  Google Scholar 

  10. Constantin JM GS, Rouby JJ, Futier E, Gallix B, Jung B, Bazin JE, Jaber S (2009) CT-scan lung morphology predicts the response to a recruitment maneuver in acute respiratory distress syndrome patients. Crit Care 13 (Suppl 1)

  11. Helm E, Talakoub O, Grasso F et al (2009) Use of dynamic CT in acute respiratory distress syndrome (ARDS) with comparison of positive and negative pressure ventilation. Eur Radiol 19:50–57

    Article  PubMed  Google Scholar 

  12. de Hoop B, Gietema H, van Ginneken B, Zanen P, Groenewegen G, Prokop M (2009) A comparison of six software packages for evaluation of solid lung nodules using semi-automated volumetry: what is the minimum increase in size to detect growth in repeated CT examinations. Eur Radiol 19:800–808

    Article  PubMed  Google Scholar 

  13. Pojunas KW, Daniels DL, Williams AL, Thorsen MK, Haughton VM (1986) Pituitary and adrenal CT of Cushing syndrome. AJR Am J Roentgenol 146:1235–1238

    CAS  PubMed  Google Scholar 

  14. Chanques G, Annane D, Jaber S, Gallix B (2007) Enlarged adrenals during septic shock. Intensive Care Med 33:1671–1672

    Article  PubMed  Google Scholar 

  15. Bone RC, Sibbald WJ, Sprung CL (1992) The ACCP-SCCM consensus conference on sepsis and organ failure. Chest 101:1481–1483

    Article  CAS  PubMed  Google Scholar 

  16. Dellinger RP, Levy MM, Carlet JM et al (2008) Surviving Sepsis Campaign: international guidelines for management of severe sepsis and septic shock: 2008. Intensive Care Med 34:17–60

    Article  PubMed  Google Scholar 

  17. Jones AE, Saak K, Kline JA (2008) Performance of the Mortality in Emergency Department Sepsis score for predicting hospital mortality among patients with severe sepsis and septic shock. Am J Emerg Med 26:689–692

    Article  PubMed  Google Scholar 

  18. Sprung CL, Annane D, Keh D et al (2008) Hydrocortisone therapy for patients with septic shock. N Engl J Med 358:111–124

    Article  CAS  PubMed  Google Scholar 

  19. Kazan-Tannus JF, Dialani V, Kataoka ML et al (2007) MR volumetry of brain and CSF in fetuses referred for ventriculomegaly. AJR Am J Roentgenol 189:145–151

    Article  PubMed  Google Scholar 

  20. Kilian AK, Schaible T, Hofmann V, Brade J, Neff KW, Busing KA (2009) Congenital diaphragmatic hernia: predictive value of MRI relative lung-to-head ratio compared with MRI fetal lung volume and sonographic lung-to-head ratio. AJR Am J Roentgenol 192:153–158

    Article  PubMed  Google Scholar 

  21. Kim HJ, Kim AY, Oh ST et al (2005) Gastric cancer staging at multi-detector row CT gastrography: comparison of transverse and volumetric CT scanning. Radiology 236:879–885

    Article  PubMed  Google Scholar 

  22. Lee SM, Kim SH, Lee JM et al (2008) Usefulness of CT volumetry for primary gastric lesions in predicting pathologic response to neoadjuvant chemotherapy in advanced gastric cancer. Abdom Imaging 34:430–440

    Article  Google Scholar 

  23. Parrish FJ (2007) Volume CT: state-of-the-art reporting. AJR Am J Roentgenol 189:528–534

    Article  PubMed  Google Scholar 

  24. Plathow C, Klopp M, Thieke C et al (2008) Therapy response in malignant pleural mesothelioma-role of MRI using RECIST, modified RECIST and volumetric approaches in comparison with CT. Eur Radiol 18:1635–1643

    Article  PubMed  Google Scholar 

  25. Prasad SR, Jhaveri KS, Saini S, Hahn PF, Halpern EF, Sumner JE (2002) CT tumor measurement for therapeutic response assessment: comparison of unidimensional, bidimensional, and volumetric techniques initial observations. Radiology 225:416–419

    Article  PubMed  Google Scholar 

  26. Zhou XP, Lu T, Wei YG, Chen XZ (2007) Liver volume variation in patients with virus-induced cirrhosis: findings on MDCT. AJR Am J Roentgenol 189:W153–W159

    Article  PubMed  Google Scholar 

  27. Dinant S, de Graaf W, Verwer BJ et al (2007) Risk assessment of posthepatectomy liver failure using hepatobiliary scintigraphy and CT volumetry. J Nucl Med 48:685–692

    Article  PubMed  Google Scholar 

  28. Das M, Ley-Zaporozhan J, Gietema HA et al (2007) Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners. Eur Radiol 17:1979–1984

    Article  PubMed  Google Scholar 

  29. Goo JM, Tongdee T, Tongdee R, Yeo K, Hildebolt CF, Bae KT (2005) Volumetric measurement of synthetic lung nodules with multi-detector row CT: effect of various image reconstruction parameters and segmentation thresholds on measurement accuracy. Radiology 235:850–856

    Article  PubMed  Google Scholar 

  30. Petrou M, Quint LE, Nan B, Baker LH (2007) Pulmonary nodule volumetric measurement variability as a function of CT slice thickness and nodule morphology. AJR Am J Roentgenol 188:306–312

    Article  PubMed  Google Scholar 

  31. Zhang J, Kang SK, Wang L, Touijer A, Hricak H (2009) Distribution of renal tumor growth rates determined by using serial volumetric CT measurements. Radiology 250:137–144

    Article  PubMed  Google Scholar 

  32. Brownlie K, Kreel L (1978) Computer assisted tomography of normal suprarenal glands. J Comput Assist Tomogr 2:1–10

    Article  CAS  PubMed  Google Scholar 

  33. El-Sherief MA, Hemmingsson A (1982) Computed tomography of the normal adrenal gland. Pathologic implications. Acta Radiol Diagn (Stockh) 23:433–442

    CAS  Google Scholar 

  34. Montagne JP, Kressel HY, Korobkin M, Moss AA (1978) Computed tomography of the normal adrenal glands. AJR Am J Roentgenol 130:963–966

    CAS  PubMed  Google Scholar 

  35. Goldman SM, Gatewood OM, Walsh PC, Dornhorst A, Siegelman SS (1982) CT configuration of the enlarged adrenal gland. J Comput Assist Tomogr 6:276–280

    Article  CAS  PubMed  Google Scholar 

  36. Rubin RT, Phillips JJ, McCracken JT, Sadow TF (1996) Adrenal gland volume in major depression: relationship to basal and stimulated pituitary-adrenal cortical axis function. Biol Psychiatry 40:89–97

    Article  CAS  PubMed  Google Scholar 

  37. Marik PE, Zaloga GP (2003) Adrenal insufficiency during septic shock. Crit Care Med 31:141–145

    Article  CAS  PubMed  Google Scholar 

  38. Vincent JL, Moreno R, Takala J et al (1996) The SOFA (Sepsis-related Organ Failure Assessment) score to describe organ dysfunction/failure. On behalf of the Working Group on Sepsis-Related Problems of the European Society of Intensive Care Medicine. Intensive Care Med 22:707–710

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgements

Dr Bonnel, M.D, Intrasense Society, Montpellier, France for logistical assistance.

Presented in part at the 2008 Annual Meeting of the French Society of Radiologists (Paris, France, October 24–28, 2008)

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Stephanie Nougaret.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Nougaret, S., Jung, B., Aufort, S. et al. Adrenal gland volume measurement in septic shock and control patients: a pilot study. Eur Radiol 20, 2348–2357 (2010). https://doi.org/10.1007/s00330-010-1804-9

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00330-010-1804-9

Keywords

Navigation