Reusable terminal tap water filters for nosocomial legionellosis prevention

  • Original Article
  • Published:
Annals of Hematology Aims and scope Submit manuscript

Abstract

Hospital water supplies often contain Legionella spp. and therefore represent a source of nosocomial infection especially for immunocompromised patients in intensive care or organ transplant units. Therefore, pathogen-free water should be provided for the care of these patients. Approaches of long-term Legionella spp. eradication from the plumbing system are rarely successful. Exposition prophylaxis might be another reasonable approach in high-risk patient care. To investigate the ability to provide water free of Legionella spp. with reusable water filters, a surveillance of splash water samples was performed. After determining the burden of Legionella spp. in the plumbing system of a paediatric oncological ward by ten unfiltered splash water samples, ten designated water taps were provided with terminal tap water filters that could be reprocessed by thermal disinfection. A further 129 samples were taken after a usage interval of 7 days and 10 more samples after a usage interval of 21 days before reprocessing the filters. All samples were checked for growth of Legionella spp. as well as other pathogenic bacteria. A total germ count of all samples was also performed. Half of the unfiltered splash water samples revealed growth of Legionella spp. All filtered water samples remained free of Legionella. Total germ count did not increase before a usage interval of 7 days. We believe the water filters tested are suitable for prevention of nosocomial legionellosis when reprocessed after 7 days as recommended by the manufacturer. To avoid retrograde contamination of filters, education of staff and patients in handling these devices is mandatory.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Umweltbundesamt (2000) Nachweis von Legionellen in Trinkwasser und Badebeckenwasser [Detection of Legionella in drinking water and bathing water]. Bundesgesundheitsblatt 43:911–915

    Google Scholar 

  2. Umweltbundesamt (2001) Verordnung zur Novellierung der Trinkwasserverordnung vom 21 Mai 2001 [German drinking water regulations revised on 21 May 2001]. Bundesgesundheitsblatt Teil 1 24:959–980

    Google Scholar 

  3. Bartlett CL, Kurtz JB, Hutchison JG, Turner GC, Wright AE (1983) Legionella in hospital and hotel water supplies. Lancet 2:1315

    Article  Google Scholar 

  4. Best M, Goetz A, Yu VL (1984) Heat eradication measures for control of nosocomial Legionnaires’ disease. Implementation, education, and cost analysis. Am J Infect Control 12:26–30

    Google Scholar 

  5. Edelstein PH, Whittaker RE, Kreiling RL, Howell CL (1982) Efficacy of ozone in eradication of Legionella pneumophila from hospital plumbing fixtures. Appl Environ Microbiol 44:1330–1333

    Google Scholar 

  6. Helms CM, Massanari RM, Wenzel RP, Pfaller MA, Moyer NP, Hall N (1988) Legionnaires’ disease associated with a hospital water system. A five-year progress report on continuous hyperchlorination. JAMA 259:2423–2427

    Article  Google Scholar 

  7. Knirsch CA, Jakob K, Schoonmaker D, Kiehlbauch JA, Wong SJ, Della-Latta P, Whittier S, Layton M, Scully B (2000) An outbreak of Legionella micdadei pneumonia in transplant patients: evaluation, molecular epidemiology, and control. Am J Med 108:290–295

    Article  Google Scholar 

  8. Knudson GB (1985) Photoreactivation of UV-irradiated Legionella pneumophila and other Legionella species. Appl Environ Microbiol 49:975–980

    Google Scholar 

  9. Marrie TJ, Haldane D, MacDonald S, Clarke K, Fanning C, Fort-Jost S, Bezanson G, Joly J (1991) Control of endemic nosocomial legionnaires’ disease by using sterile potable water for high risk patients. Epidemiol Infect 107:591–605

    Google Scholar 

  10. Mathys W, Deng MC, Meyer J, Junge-Mathys E (1999) Fatal nosocomial Legionnaires’ disease after heart transplantation: clinical course, epidemiology and prevention strategies for the highly immunocompromised host. J Hosp Infect 43:242–246

    Article  Google Scholar 

  11. Pitten FA, Rudolph P, Kramer A (2001) Mikrobiologische Qualität von Trinkwasser in Risikobereichen [Microbiological quality of drinking water in high risk areas]. Bundesgesundheitsblatt 44:155–158

    Article  Google Scholar 

  12. Stout JE, Yu VL (2003) Experiences of the first 16 hospitals using copper–silver ionization for Legionella control: implications for the evaluation of other disinfection modalities. Infect Control Hosp Epidemiol 24:563–568

    Google Scholar 

  13. Tablan OC, Anderson LJ, Besser R, Bridges C, Hajjeh R (2005) Guidelines for preventing health-care-associated pneumonia, 2003: recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee. Morb Mort Wkly Rep Recomm Rep 53:1–36

    Google Scholar 

  14. Vonberg R, Eckmanns T, Bruderek J, Ruden H, Gastmeier P (2004) Use of terminal tap water filter systems for nosocomial Legionellosis prevention. J Hosp Infect (in press)

  15. Walter CW (1982) Legionella pneumophila in a hospital water supply. N Engl J Med 307:379–380

    Google Scholar 

  16. Wendt C, Weist K, Dietz E, Schlattmann P, Ruden H (1995) Field study to obtain Legionella-free water from showers and sinks of a transplantation unit by a system of water filters. Zentralbl Hyg Umweltmed 196:515–531

    Google Scholar 

  17. Zacheus OM, Martikainen PJ (1996) Effect of heat flushing on the concentrations of Legionella pneumophila and other heterotrophic microbes in hot water systems of apartment buildings. Can J Microbiol 42:811–818

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ralf-Peter Vonberg.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Vonberg, RP., Rotermund-Rauchenberger, D. & Gastmeier, P. Reusable terminal tap water filters for nosocomial legionellosis prevention. Ann Hematol 84, 403–405 (2005). https://doi.org/10.1007/s00277-004-1000-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00277-004-1000-6

Keywords

Navigation